Get complete information related to latest Plug Holder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plug Holder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plug Holder Tenders.
Tender For supply of power contactor for net 1 & 2 conforming to is/iec: 60947-4-1 with 2 no + 2 nc aux. contact of utilization category %u2013 6a, rated voltage 1000 v ac, main pole -4, control voltage 415 v ac %b1 15% with surge suppressor of type/make: lc1d1150046n5+la4da2n+ladn22 of schneider make or af190b-40-22 of abb make or 3rt23461avo04aa0+3rh29111ha11+3rt9361beo00 of siemens make or mcx-34 of l&t make as per rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) and as per update of common bom items issued by rdso lr. no. el/7.1.108/mssbc, dt. 17/09/21. acceptable makes: abb/schneider/siemens/l&t only. offers from manufacturers/authorized dealers shallbe considered only. specn: rdso spec. no. rdso/pe/spec/ac/0184- 2015(rev.1) [ warranty period:30 months after the date of delivery ]
Tender For supply of contactor (with diode) for ventilation fan unit 1 and 2 condenser, cd1.1, cd 1.2, cd 2.1, cd 2.2, heater 1 &2. rated current 16 a (at rated voltage & ac-3 utilization category), rated voltage 690 v ac, main pole 3 no, auxiliary contact 1 nc, control voltage 77-143 v dc with surge suppressor as rdso specification no. rdso/pe/ spec/ ac/ 0184-2015 (rev-1). [ warranty period: 30 months after the date of delivery ]
Tender For supply of contactor current rating: 95 a, ac3, voltage rating:415 v ac, main pole: 3 no, aux. contact: 2no+1nc, control voltage: 168-300 v ac, with surge suppressor of make:abb(af96-30-11-13), schneider(lc1d95m5+la4da2u), siemens(3rt1046-1al20-8k, 3rt1926-1bd00) as per drg.no. rdso/pe/spec/ac/0184-2015 (rev-0) specn: rdso/pe/spec/ac/0184-2015 (rev-0) [ warranty period: 30 months after the date of delivery ]
Tender For supply of 3 pole power contactor 415 v ,50hz, ac-3 -170 a duty with auxiliary contact 2no+nc block,coil volt -110 v ac , rating -170a, as per iec- 60947, is- 13947 or latest. model-3 tf 52 of m/s. siemens or equivalent in bch, abb, schneider, c&s, l&t or any isi marked product with past performance in railway inlast 3 years. [ warranty period: 12 months after the date of delivery ]
Tender For supply of contactor for 60 kva transformer rated current -95 amp, rated voltage- 690 v ac, main pole - 4, auxillary contact 1 no + 1 nc, control voltage - 230 volt ac +/- 30% (168 v ac 300 vac) with add on auxiliary contact block and surge suppressor .conf to bom letter no.el/7.1.108/mssbc dt.- 17-09-2021 & rdso letter no. el/7.1.108/mssbc dt.- 24-06-2021. make- abb (af116b-40) only [ warranty period: 30 months after the date of delivery ]
Tender For supply of power contactor for feeder - 1 & feeder- 2 and bus coupler, 3 pole, 1000v ac, 50 hz, suitable for 500kva, 750v ac on load switching under ac-6a category at temperature of 70 degree celsius & coil voltage of 110v+25% -30% dc with surge suppressor, aux. contacts 2no+2nc as per rdso specification no. rdso/pe/spec/tl/0195-2019 (rev.0) suitable for switch board cabinet for hog compliant lslrd coaches. [ warranty period: 30 months after the date of delivery ]
Tender For supply of power contactor, 3 pole, 1000v ac 800a, 50hz, suitable for 500kva, 750v ac on load switchingunder ac -6a catageory at tempreature of 70 degree c & coil voltage of 110v+ 25%-30%(48-130 volt) dc with surge suppressor, 2no+2nc, according to bill of material o f rdso spec no rdso/pe/spec/d/tl/0195-2019 (rev-0) similar to abb make model no af1250-30-11, make- abb/siemens/scneider or equivalent. material should be same in dimension as abb make model no af1250-30 material procured from oem or authorized dealer only. proof of originality and test certificate should be given by the supplier along with offer. without certificate material will not be accepted [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of 3 pole air break power contactor d d -3 pole air break power contact -tor ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 24v dc , aux. contacts 2no+2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 24v dc , aux. contacts 2no+2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact -or ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole air break power contact tor ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting ,
Tender For : supply of 240 v ac, 50 hz, 2 pole, 32 a power contactor with 2 no and 2 nc auxiliary contacts suitable and retrofittable into existing 5kva suntron make cls panel. the contactors shall be of electromagnetic air break type of robust design. the contacts shall be silver plated, bounce proof and have amplecross section for carrying the rated current continuously without exceeding the permissible temperature rise. it shall conformed to is/iec: is 13947 ( part 3 ) : 1993/i. make: l&t , abb, c&s, schneider, siemens, yule,telemechanique.or similar. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 240 v ac, 50 hz, 2 pole, 65 a power contactor with 2 no and 2 nc auxiliary contacts suitable and retrofittable into existing 60a capacity suntron make cls panel the contactors shall be of electromagnetic air break type of robust design. the contacts shall be silver plated, bounce proof and have ample cross section for carrying the rated current continuously without exceeding the permissible temperature rise. it shall conformed to is/iec: is 13947 ( part 3 ) : 1993/i. make: l&t , abb, c&s, schneider, siemens,yule, telemechanique.or similar [ warranty period: 30 months after the date of delivery ]