Tender For supply of hach make 1 year spare part kit sodium,hach make solenoid valve 3 by 2 way nps 0.8,hach make solenoid valve on overflow vessel,hach make pump 24vdc membrane,hach make gas-pump 80v resistant to dipa,hach make pompe microdebit 24vcc a impulsions,hach make micro-pulses pump regeneration
Tender For corrigendum : tender for acid concentration - acid concentration part a, 1294200, each 1 ltr. of liquid concentrate contains:sodium chloride i.p 210.0 gm ,sodium 137.60 mmol ,calcium chloride i.p 8.0 gm, calcium 1.55 mmol , magnesium chloride i.p 2.7 gm ,magnesium 0.38 mmol ,acetic acid, glacial i.p 6.3 gm mmol, bicarbonate 32.0 ,purified water i.p qs ,chloride 106.4, acetate 3.0 dilution : 35x, dry bicarbonate concentrate powder cartridge (650gm) -(1), 1292800, dry bicarbonate concentrate powder cartridge (650gm) to be fixed to surdial 55 plus to produce inline bicarbonate solution without manual mixing dry bicarbonate should be compatible to dilution ratio 1+34.dry bicarbonate should competable to part a with (k free, k2, k3,k4, dextrose, without dextrose) .dry bicarbonate packing material should be environment friendly. (pp material preferable ), endotoxin filter (fmc), 485000, endotoxin filter it should be fixed to nipro h.d. machine for producing ultrapure dialysate it should have us fda or ce approval, haemodialysis on-off kit for dialysis procedure convenience, 651200, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, dialyzer (low/middle flux)- 1.0 m2 to 1.1 m2, 53300, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, av bloodline set post pump- hd machine (adult), 2089800, material polysulphone/ polyamide blend/ polyethersulphone/pmma (1) disposable & single use adult tubing set(2) kink resistant tubing material (3) medical grade pvc material tubing set(4) sterile, non-pyrogenic & non-toxic(5) post pump tubing set(6) tubing set contain-01 no. of transducer protector for venous line(7) to complete the circuit of haemodialysis, all necessary accessories must contain in set.(8) filling volume :100-120ml, arteriovenous fistula(avf) needle (16/17g), 507800, hydrogen peroxide 21percentage w/w, paracetic acid 4percentage w/w, acetic aced 10percentage w/wcolorless biodegradable liquidpackaging: virgin hdpe jerry canniister 5 litrestorage: stable at room temperature, hot disinfectant for hemodialysis(h.d.) / hemodiafiltration( hdf) machine / water treatment system, 436300, (1)13- 13.5 cm catheter length(2) polyurethane bio-compatible material with catheter clamp and luer lock(3) radio-opaque(4) kit should contain 2 dilators: 1st dilator 10f 12-15 cm and 2nd dilator 12f 15cm as per requirement. (5) kit should contain guidewire size of 0.038 inch or 0.035 inch as per requirement., double lumen dialysis catheter kit 11.5-12 fr. x 15-16 cm curved/straight, 140800, (1) 9-12 cm catheter length(2) polyurethane bio-compatible material with catheter clamp and luer lock(3) radio-opaque(4) kit should contain 1 dilators: 9f 12-15 cm(5) kit should contain guidewire size of 0.025 inch, transparent film dressing - 10cm x 12cm, 25400, non adherent sterile dressingnon-woven material, transparent 1-3 layered
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For supply and commissioning of set of pneumaticgreasepumps . set consist of three items as per annexure enclosed. note:- 1. the supplier should ensure that all necessary fittings and its associated accessories to be supplied along with the machine for effective commissioning in the field. 2. make/ brand - groz or prima or elgi or taparia. 3. necessary calibration certificate to be submitted along with supply for flow meter. 4. the traders without valid authorization certificate from oem, the offer could not be evaluated. firm should submit authorized dealership certificate, otherwise offer will not be considered. 5.oem/authorized dealer of the product with service backup only to quote. [ warranty period: 30 months after the date of delivery ]