Get complete information related to latest Pole Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Breaker Tenders.
Tender For appointment of specialized consultant for obtaining consent to operate from mpcb for housing scheme under package-iv at plot-01 and 03 at kharkopar (e,w), ulwe.
Tender For corrigendum : supply of various switchgear spares for emd-3,wtps. - abb make 3 pole power contactor type : ax50-30-11, coil voltage 110 v,50 hz ac, abb make 3 pole power contactor type : ax80-30-11, coil voltage 110 v,50 hz ac, abb make auxiliary contactor 110 v ac, 2no + 2nc contact,type n22e, front mounted add on block(suitable for contactor type: ca5x-22e; 2 no + 2 nc, abb make, abb make tmax 3 pole motor protection circuit breakers type : t2s 160, in : 52a, icu : 50ka, auxiliary contact for mpcb hkf1-11 with 1no+1nc contact, over load relay, abb make ,type ta25du14m,range 10-14 a, abb make thermal overload relay type : ta75du 42, amp range : 29a to 42a, abb make thermal overload relay type : ta75du 52, amp range : 36a to 52a, siemens make mccb 3-pole 125a breaking capacity 55ka at 415v, 50hz reference no:-3va1112-5ee32-0aa0, vaccume contactor 300 amp. rating 415 volt with 2 no + 2 nc coil voltage 110v ac., aux.contact block - 1no + 1 nc for vacuum contactor type 3rt - 12, control & switchgear make digitalmotor protection relay.type-csmpm-06 si, 1.5kw l&t mf 1-1 phase dol starter category ss97227, l&t make dol starter,in sheet-steel enclosure,type-mk1,415v,50hz,3ph,o/l relay range -4 to 6.5 a,cat no-ss 96210poto, l&t- make, auxiliary contactor, type : mn 0-31 e, 3 no + 1 nc, ue: 415 v, ie: 4 a, ui: 690 v, ith: 10 a, ac-15, coil voltage : 110 v ac, l&t- make, auxiliary contactor, type : mn 0-22 e, 2 no + 2 nc, ue: 415 v, ie: 4 a, ui: 690 v, ith: 10 a, ac-15, coil voltage : 110 vac, contactor type ml.1.5, 25 amp, 230v, operating coil voltage, l&t catalogue no 5591857, l&t make um -no, l&t make,3pole power contactor in open execution type ml-2 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 32a cat.no.ss 90701, l&t make 415v switch gear (acb), l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make power contactor type ml-4 with 2 no + 2 nc aux. contact, coil voltage 220v ac, ac-3 70 amp. rating, cat. no.-ss 90910, l&t make power contactor type ml-6 with 2 no + 2 nc aux. contact, coil voltage 220v ac, ac-3 110 amp. rating cat/. no-ss90921, power contactor,tp,ac-3 duty,coil voltage-240 v ac,type: mnx-40, l&t make 3 pole power contactor, type mnx45, ac-3 phase, rating 45a, coil voltage- 415 v ac, along with 2 no+2 nc, l&t make 3 pole power contactor with coil, type mnx 70, ac-3 rating 70a, coil voltage 415 v ac, cat.no.cs97076 suffix: d000, 220v dc auxiliary contactor 2no+2nc cat no : tca3 dn22, 220v dc auxiliary contactor 4no cat no : tca3 dn40, ml 4 con. kit set cat no ss 91660 l & t make, spare coil for ml10/ml11/ml12 contactor cat. no. ss91011, make - l & t, thermal over load relay 2.5-4 a (l&t) 678109, l&t make bi metal o/l relay type ml range 6.0-10a , cat no ss 9185800vo, l&t make 415v switch gear (acb), l&t make thermal over load relay with alarm contact.type : ml - 1, catlouge no ss91858,amp. range : 10.0 to 16.0, l&t make bi metal o/l relay for ml -2 range 13-21a , cat no ss 9185900co, l&t make 415v switch gear (acb), thermal o/l relay(l&t) range:20 to 32a,type:ml 2/3 relay,cat no:ss 91859, bimetel overload relay range 28-42 amp., bimetal thermal overload relay, range: 30-50a, l & t make auxiliary contact block,mx-a1 11e (aux contact block) 1 no + 1 nc, add-on auxiliary contact block suitable for auxiliary contactor, front mounting, make : l & t, type : mx-a1-22e, 2 no + 2 nc, ue: 415 v, ie: 3 a, ui : 690 v, ith : 10 a, ac-15, addon block contact make: l&t ,mnxa2(1no+1nc contact) ui-415 ,ith-10a ,ie-4a ac15, l&t make aux contact add-on of mnx type contactor for 2no + 2nc cat no:- cs94114, l&t make 3-position selector actuator (switch) catalogue no. ss91517, auxi block type :3tx 4 010 -2a :1 no, auxi blocktype :3tx 4 001-2a :1 nc, contact block
Tender For supply of 24baic003 boq--lamp indicating blue 230vac, switch on-off (toggle-black), rotolock valve level transmitter, fuse glass 5a, lamp indicating red 230vac, lamp indicating yellow 230vac, mcb 5sl4210-7rc, expansion board, solenoid valve, mpcb for blower, electric regulating valve, one card of each type of the controller & compressor, plc module set, flow switch set, set of all fuse links (fuse set (one of each type), set of all filters in the gas line, set of all power capacitors, set of all valves in sea water chilled water and gas lines, set of all hmis, pressure gauge set, set of all analog gauges, set of all cut outprotections (both compresr elec panels), set of all zinc anodes, set of all push buttons, set of all o rings (rubber and teflon), pump shaft cw pump, pump shaft sw pump, set of all transformers, mcb 5sl41027rc (2a), pressure relief valve, check valve 4, butterfly valve for suction line, electronic expansion valve, drier for motor cooling line, manifolfd brass 1 1 8
Tender For various work in lhb ac coaches of gkp & ash depot of ljn division :- (1) provision of single connection arrangement at the input of mpcb/mcb instead of looping as per rdso modification sheet no rdso/pe/ms/ac/0097-2025(rev.0), (2) repairing of exhaust blower motor in lavatories, (3) repair/rewiring of cut/damaged upper gear and under gear wiring in lhb ac coaches.
Tender For work for modification of single connection arrangement at the input of mpcb/mcb instead of existing looping arrangement in lhb type eog/hog coaches & power cars as per rdso modification sheet no. rdso/pe/ms/ac/0097-2025(rev.0) or latest.
Tender For supply of mpcb (motor protection circuit breaker) of current rating: 1.6 amps, thermal release range: 1.1 to 1.6 amps, class-10, breaking capacity: 50 ka, 3 pole, voltage rating 415 v ac with 01 no + 01 nc auxiliary contact block as per rdso spec. no. rdso/pe/spec/ac/0184-2015 rev.1 to abb model no.:ms132-1.6b, schneider model no. gv2me06, l&t model no. st41894oooo, siemens model no. 3rv2011-1aa10 and eaton model no. pkzm0-1.6.
Tender For supply, installation, commissioning of online effluent monitoring system and parameters data transmission to mpcb & cpcb server for etp at nashik tps