Get complete information related to latest Pole Structure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Structure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Structure Tenders.
Tender For construction of bathroom block, septic tank deep drain with grating, interlock tile, iron mesh grating at the top of boundary wall and other allied work in pcr jammu under account head building and structure in demand 51 police
Tender For corrigendum : provision of additional transformer alongwith associated items at af stn pune under ge (af)lohegaon - s & f steel tubular swaged poles complete with cast iron plate, finial taper plug, bolt, nuts & screws as specified type 410 sp-55 (11 mtr long) including one coat of red oxide primer and two coats of aluminium paint and making 30 cm wide strips (total -05 nos) with yellow and black paint alternately on external surface above column/pcc benching including numbering with black paint and painting with bitumenous paint internally and externally for portion embedded complete all as specified and directed., s & f air break gang operated switch with 12 nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement consisting of ms chanel ht post type insulator copper alloy, high pressure assembly drop out fuses operating rod of 20 mm dia gi pipe (medium grade) for operating from 1.2 m above gl complete including drop out fuses conforming to is-9921 part-i to v (1982 to 1985) of 1972 rated voltage 11 kv and for current rating 200 amp all as specified, material and labour for lightning arresters nominal discharge current peak 65 ka rating, suitable for operation on ht 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-in forced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for withstanding from the effects of pollution, rain, heat and with moisture seal , stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements complete all as specified and as directed., m&l for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e m.s. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of aluminium paint (1st quality ) as reqd complete as specified., m & l for cement concrete 1:3:6 type c1 (using 20 mm graded aggregate) as lean concrete for coping of pole, stay foundation etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified, material and labour for cement concrete 1:2:4, type b-2 (using 40 mm graded stone aggregate) as lean concrete for road finishing even and fair without using extra cement complete all as specified and as directed., supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm., s&f of cable end jointing kit 95 sqmm, 3 core xlpe 11kv ht cable cold shrinkable outdoor type, incl carrying out 5kv megger test after jointing complete all as specified and directed by engr-in-charge., s&f of cable end jointing kit 95 sqmm, 3 core xlpe 11kv ht cable cold shrinkable indoor type, incl carrying out 5kv megger test after jointing ,complete all as specified and directed by engr-in-charge., supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 400 sq mm including aluminium lugs, cable glands ,complete all as specified and directed by engr-in-charge., supply, laying & testing industral pvc frls insulated single core flexible cable, electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size single core 185 sq mm, including copper cable lugs, cable glands ,complete all as specified and directed by engr-in-charge., supply and install, testing and commisioning of outdoor transformer as per is : 1180 part-i, level-ii step down, c
Tender For corrigendum : supply of supply of 11 kv v type cross arm clamp , supply of 3 phase dis. box clamp with nut and bolts , supply of connecting cable , supply of l.t. fuse set protection box , supply of tinned copper fuse wire different size , supply of hdpe pipe , supply of stone pad , supply of holding clamp , supply of ms angle , supply of t-off chhanel , supply of top chhanel 125x65x240 , supply of dropper channel 100x50x2028 mm. , supply of danger board with clamp and nut and bolt , supply of g.i. patti clamp nut and bolts , supply of l.t. tail less unit , supply of copper l-pieace , supply of 11 kv f clamp , supply of suspension clamp , supply of dead end clamp , supply of eye i hook , supply of eye bolts for guarding , supply of j hook , supply of lt clamp , supply of pearcing connector , supply of alluminium lug 120 sq.mm. , supply of alluminium lug 240 sq.mm. , supply of alluminium lug 70 sq.mm. , supply of nut bolts and washers off size , supply of guarding angel , supply of guarding angel clamp , supply of m.s. angel iron 65x65x6 mm. , carriage of 9 m stp pole-sp- 55 galvanised , carriage of 11 m stp pole-sp- 55 galvanised , carriage of 8.5 m pcc pole , carriage of v type cross arm for 11 kv , carriage of 11 kv pin insulator with pin , carriage of disc insulator with fitting t and c 45 kn , carriage of 11 kv fuse set , carriage of 11 kv tpmo with polymer insulator , carriage of complete stay , carriage of distribution transformer 25 kva , carriage of distribution transformer 63 kva , carriage of distribution transformer 100 kva , carriage of distribution transformer 250 kva , carriage of acsr dog conductor , carriage of acsr weasel conductor , carriage of m s earthing rod 20 x2540 mm , carriage of lt al. xlpe cable size 1x240 sq.mm. , carriage of lt pvc cable 1x120 sq.mm. for dtr , carriage of lt pvc armoured cable size 3.5x70 or 35 sq.mm. , carriage of 11 ) /bid number : gem/2026/b/7551524 * /dated: 20-05-2026 & & / bid document 1 / 54 kv xlpe cable 3x185 sq.mm. , carriage of lt ab cable 3x120 sq.mm. , carriage of lt ab cable 3x50 sq.mm. , carriage of lt ab cable 3x95 sq.mm. , carriage of lt pvc armoured cable size 4x25 sq.mm. , carriage of 33 kv xlpe cable 3x300 sq.mm. , carriage of 33 kv indoor or outdoor jointing kit , carriage of 11 kv indoor or outdoor jointing kit , carriage of 33 kv straight through , carriage of 11 kv straight through size 3x185 sq.mm. , carriage of 11 kv vcb , carriage of g.i. wire 6 or 8 swg for guarding , carriage of three phase distribution box , erection of l.t. fuse set protection box , execution of chemical earthing with g.i. patti clamp nut and bolts , execution of pipe earthing with g.i. patti clamp nut and bolts , erection of l.t. tail less unit with all respective material , laying of acsr dog conductor , laying of acsr weasel conductor , laying of lt ab cable 3x120 sq.mm. , laying of lt ab cable 3x50 sq.mm. , laying of lt ab cable 3x95 sq.mm. , mounting of 3 phase distribution box , erection of double polestructure , erection of single polestructure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of distribution transformers , plinth work , installation of transformers 11 or 0.4 kv t or f 25 kva , installation of transformers 11 or 0.4 kv t or f 63 kva , installation of transformers 11 or 0.4 kv t or f 100 kva , installation of transformers 11 or 0.4 kv t or f 250 kva , laying of cable 11 kv xlpe cable 3x185 sq.mm. , laying of cable 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit , installation of 11 kv indoor or outdoor jointing kit , installation of 33 kv straight through , installation of 11 kv straight through , installation of 11 kv vcb , dismentlling of jarjar g.i. wire and weasel conducter , received back of distribution transformer
Tender For corrigendum : supply of carriage of distribution transformer 25 kva from esc mnp , carriage of distribution transformer 63 kva from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr weasel conductor from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable 1x400 sq.mm. for dtr from esc mnp , carriage of lt xlpe cable size 3.5x70 or 35 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x50 1x35 1x16 sq.mm. from esc mnp , carriage of lt ab cable 3x95 1x70 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 33 kv straight through size 3x300 sq.mm. from esc mnp , carriage of g.i. wire 6 or 8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of lt fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr weasel conductor , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , laying of lt ab cable 3x50 1x35 1x16 sq.mm. , laying of lt ab cable 3x95 1x70 1x16 sq.mm. , mounting of three phase distribution box , erection of double polestructure 8.5 mtr pcc pole , erection of single polestructure 8.5 mtrs pcc pole , erection of tri polestructure 33 kv 13 mtr st pole , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line , fencing of 250 kva distribution transformers , plinth for 250 kva transformer , installation of 11by0.4 kv tf 25 kva , installation of 11by0.4 kv tf 63 kva , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , dismentlling, received back and safe carriage of jarjar g.i. wire and weasel conducter including with rolling from pit site to esc, mainpuri , received back of distribution transformer after increasing capacity from pit site to esc, mainpuri
Tender For corrigendum : supply of stay rod 20x1800 mm, etc material from esc mnp , carriage of distribution transformer 100 kva from esc mnp , carriage of distribution transformer 250 kva from esc mnp , carriage of acsr rabbit conductor from esc mnp , carriage of acsr weasel conductor or insulated conductor as provided by department from esc mnp , carriage of m s earthing rod 20 x2540 mm from esc mnp , carriage of lt al. xlpe cable size 1x240 sq.mm. from esc mnp , carriage of lt xlpe cable 1x120 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x185 sq.mm. from esc mnp , carriage of lt ab cable 3x120 1x95 1x16 sq.mm. from esc mnp , carriage of 33 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv xlpe cable 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. from esc mnp , carriage of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. from esc mnp , carriage of 11 kv straight through size 3x185 sq.mm. from esc mnp , carriage of 11 kv vcb for og ctr 200by100by5a 350 mva 1250 amp. from esc mnp , carriage of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. from esc mnp , carriage of g.i. wire 6or8 swg for guarding from esc mnp , carriage of three phase distribution box from esc mnp , erection of fixing of l.t. fuse set protection box with all respective accessories as per norms , execution of chemical earthing with g.i. patti clamp nut and bolts as per norms , erection of l.t. tail less unit with all respective material as grouted angel with fabrication work etc. , laying of acsr rabbit conductor , laying of acsr weasel conductor or insulated conductor as provided by department , laying of lt ab cable 3x120 1x95 1x16 sq.mm. , mounting of three phase distribution box , erection of double polestructure , erection of single polestructure , grouting of pcc or stp pole , grouting of stay , earthing of pole , guarding of 11 kv line with gaurding angel etc , fencing of distribution transformers , make plinth for 250 kva transformer proper size as per resspo norms , installation of 11by0.4 kv tf 100 kva , installation of 11by0.4 kv tf 250 kva , laying of 11 kv xlpe cable 3x185 sq.mm. , laying of 11 kv xlpe cable 3x300 sq.mm. , laying of 33 kv xlpe cable 3x300 sq.mm. , installation of 33 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x185 sq.mm. as per norms. , installation of 11 kv indoor or outdoor jointing kit size 3x300 sq.mm. as per norms. , installation of 11 kv straight through size 3x185 sq.mm. as per norms. , installation of 11 kv vcb og ctr 200by100by5a 350 mva 1250 amp. , installation of 11 kv vcb ic ctr 600by300by5a 350 mva 1250 amp. , dismentlling of old and damaged cable of different size , received back of distribution transformer after increasing capacity
Tender For supply of site clearance and amp earthwork is 1200,kero heater,pcc is456,rcc m20 footing and column and slab,reinforcement steel fe500,brickwork 230mm is1077 and flooring anti skid,internal plaster 12mm,doors flush and windows alluminum and glass,electrical led and wiring,plumbing and sanitary,ceiling gypsum vip,painting exterior and interior external lighting and poles,water supply tank and pump,transportation and logistics remote area,contingencies and solar panel 5kva and invertor and battery 5kva,generator 5 kva electrical led and wiring is 732,mirror 5 h 2w ft and bench 5 h 2w ft,chair plastic with arm,toilet sheet western with exhaust fan and water faucet and hand jet assy,electric fitting work,changing room 6 by 6 by 10 ft and bathroom 6 by 6 by 10 f,multipurpose hall structure,chair vip sofa and centre table,podium and tt table and carrom set,yoga mats fire extinguisher,86 inch interactive pannel,drainage and cement road work tin shed wk on viewer seating iron poles and tin sheet hooks screw and iron channel,gr
Tender For corrigendum : work of name :- remaining work pkg. no. rj-23-10/srf (rr) / np / 2022-23 distt kota - providing, laying and spreading and compacting specified graded crushed stone in sub-base course including premixing the material at omc in mechanical mixer (pug mill), carriage of mixed material, laying in uniform layers with motor grader, f.e. loader, on a prepared surface and compacting with vibratory compactor to achieve the desired density including all material, labour, machinery, lighting barricading and maintenance of driversion complete. (morth specification clause 401). with all lead & lift, fdkuiqjk rfd;k ls punzsly, total, kilometre stone reinforced cement concrete m15grade kilometre stone of standard design as per irc:8-1980, fixing in position including painting and printing etc ordinary kilometer stone (precast), fdkuiqjk rfd;k ls punzsly, e.mkuk ls guksfr;k, total, kilometre stone reinforced cement concrete m15grade kilometre stone of standard design as per irc:8-1980, fixing in position including painting and printing etc hectometer stone (precast), fdkuiqjk rfd;k ls punzsly, e.mkuk ls guksfr;k, total, providing and erecting typical citizens information board as per approved drawing & specification of mord, made of two ms sheet of 1.6 mm thick each of size 900 mm 750 mm stiffened by angle iron 25 mm 25 mm 3 mm all around the plate and plates fixed on frame of 75 mm dia pipe of 12 swg sheet (vertical post 3050 m with angle holdfasts and horizontal member 900 mm) to be joined by 5 mm thick ms plate at 12 places (65 50 mm) duly embedded in cement concrete m-15 grade of block of 600 mm 600 mm 750 mm size below ground level as per enclosed drawings & as directed by engineering - in-charge. all ms will be stove enameled on both side, lettering, figuring and border will be with ready mixed synthetic enamel paint of superior quality in required shade and colour etc. complete in all respect. all sections of framed post and steel tube will be painted with primer and two coat of epoxy paint as per drawing and as per mord specification., fdkuiqjk rfd;k ls punzsly, e.mkuk ls guksfr;k, total, providing and laying reinforced cement concrete pipes np-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (morth specification : clause 1000/2900). 300 mm dia, fdkuiqjk rfd;k ls punzsly, e.mkuk ls guksfr;k, total, dry lean cement concrete sub - base. construction of dry lean cement concrete 1:3:6 sub-base over a prepared sub-grade with coarse and fine aggregate conforming to is: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blening to be as per table 600-1, cement content not to be less than 200 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing., fdkuiqjk rfd;k ls punzsly, total, providing and laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to is:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or fix form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures and vacuum processing pump as approved, curing compound, finishing to lines and grades as per drawing as per morth specification : clause no. 602, 112. using cement concrete m-30 pavement grade, fdkuiqjk rfd;k ls punzsly, total, earthwork in excavation for foundation of structure complete with all l