Get complete information related to latest Pole Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Transformer Tenders.
Tender For repair to ht external electric installation ug electric supply line, distribution transformer and other allied works services under ge narangi
Tender For periodical servicing, checking recharging, repair / nstallation /maint of various type of earthing, power/ distribution transformer alongwith rmu, vcb with replacement of burnt out ht and lt joint, cables, unsv lt panels, electric coils, poles
Tender For supply of 33 kv high insulation paint for insulation purpose. di-electric strength 59kv/mmstable up to 200 deg, excellent resistance to uvradiation, excellent resistance to transformer oil,tough and scratch resistant, excellent corrosion resistance, quick drying at room temperature. make: insulect sk-03/ casewell or similar
Tender For tender for supply of lab equipment for electric circuit and transformer generator lab to dept. of electrical and electronics engineering, vtu constituent college, chintamani - ac to dc converted (0 to 300v variable), dc shunt motor and 3 phase synchronous generator coupled set with a rating of 5hp motor and 3kva generator with 1500rpm speed, single phase auto transformer 2kva, dry type single phase transformer 2kva with tapping of 33.3%, 50% and 83% shell type, dry type 1 phase transformer 2kva with tapping of 33.3%, 50% and 83% shell type, dry type single phase transformer 1kva with tapping of 33.3%, 50% and 83% shell type, stepdown transformers (0 to 6v), (0 to 9v) and (0 to 12v) each 05, single strand connecting wires, bread board, cro probes, transistor sl100,bf194, diodes by127, diodes in4001, digital multimeter, one phase load (rheaostatic), three phase load rheostatic, capacitors 0.01uf,0.1uf,1uf each 10, capacitor 0.1,0.01,100,0.22,0.47,1.3nf,47,47pf each 10, inductor 1mh, 2mh,5mh, 10mh, 20mh and 50mh each 10, dual trace oscilloscope 20mhz, function generator 1mhz, ac wattmeter (0 to 3000wts), (0 to 6000wts) each 05, dc voltmeter (0 to 100vts), dc ammeter (0 to 5amps), (0 to 10amps) each 05, ac voltmeter (0 to 300vts) (0 to 600vts) each 05, ac ammeter (0 to 5amps), (0 to 10amps), (0 to 15amps) each 05, regulated power supply 0-30v (dual), resistors 1k,10k,3.3k,470,22k,33k,3.3k each 10
Tender For supply of electric line material under electric supply area medininagar - electrical items :, earth clamp for earth wire (50x6 mm) 1.8 kgs (galvanized), earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs long (bentonite as intermittent layers) (galvanized), 33 kv v cross arm(100x50x6) 19.7 kg for rail (galvanized), 33 kv pole top bracket (100x50x6) 2.9 kg for rail (galvanized), b/c for 33 kv v for rail 3.2 kg (galvanized), b/c for 33 kv top for rail 3.2 kg (galvanized), 11 kv v cross arm for 200 kg pole (75x40x6) 10.93 kg(galvanized), 11 kv pole top bracket for 200 kg pole (75x40x6) 2.1 kg (galvanized), b/c for 11 kv v cross arm for 200kg pole (50x6) 2.8 kg (galvanized), b/c for 11 kv pole top bracket for 200kg pole (galvanized), 11 kv v cross arm for 400 kg pole (100x50x6) 16 kg (galvanized), 11 kv pole top bracket/f clamp(50x6) 2.1 kg for 400 kg pole (galvanized), b/c for 11 kv v cross arm for 400 kg pole (50x6) 3 kg (galvanized), b/c for 11 kv pole top bracket for 400 kg pole (50x6) 3 kg (galvanized), b/c for v bracket for 400 kg pole 3.2 kg (50x6) (galvanized), b/c for top bracket for 400 kg pole 3.2 kg (50x6) (galvanized), side stay clamp 400 kg psc pole (galvanized), angle stay clamp 400 kg psc pole (50x8) 1.9 kg (galvanized), side stay clamp 200 kg pole (50x6) 1.08 kg (galvanized), angle stay clamp 200 kg psc pole (galvanized), clamp for transformer base/top (galvanized), g.i stay set d/s/s (1900x20 mm) with stay wire 7/10 swg & guy insulator (galvanized), d.p channel support clamp (50x6) mm 1.1 kg (galvanized), gi wire no. 6/8/10 (galvanized), 11 kv stay set complete (1800x16 mm) with stay wire 7/10 swg and guy insulator (galvanized), galvanized nuts & bolts (3"/5" full thread /7"/8"/9"/10"/12" half thread size), lt stay set complete (1700x16 mm) with stay wire 7/12 swg (galvanized)
Tender For provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, power factor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & nuts etc as req
Tender For supply of electric and mechanic items d d - fail safe relay , f switch , transformer , stator , contactor pwr, , 15v is signalling bell , plug and socket assy , isolator 300 amps on off , audio visual alarm ava for haulage , brkr crct mccb,400a, , tester ht line,11kv , insulator bshng, 11kv, prcln , mat insltd rbr, 1m, 2m, 2.5mm 11kv