Get complete information related to latest Portable Rectifier Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Portable Rectifier Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Portable Rectifier Tenders.
Tender For supply of transformer maintenance supply installation of earth pits shunt capacitor ab switch acb pfcontroller : : - one time maintenance off 315kva transformer , supply and installation of horizontal 3 phase 11kv 400amp gang operated air break switch , supply and installation of 1000a 4 pole air circuit breaker , supply and installation of copper bonded chemical earth pits , supply and installation of copper plate earth pits , supply and installation of shunt power capacitors of the self healing type for ac systems , supply and installation of automatic power factor controller , supply and installation of lighting arresters for 11kv sub station
Tender For 4 pole, 300amps. 600vac contactor for 60 kva transformer of power car control panel (k-44 & k-46) along with auxiliary contact block 1no+1nc coil voltage: 400-415 vac model l :- ek210-40-11-400 -415v, 50hz. make :- contactor make and type are similar as per abb made contactor ek 210 with coil volta ge 415v and with auxiliary contact block 1no+1nc / siemens.note:- 1.oem or authorized dealer only to qu ote with dealership certificate. 2. sample should be approved before bulk supply [ warranty period: 30 m onths after the date of delivery ]
Tender For auction sale of m.s. steel meltable scrap,steel scrap round pole,scrap ms iron,steel scrap r. s. joists pieces,steel scrap rail pieces,transformer tank scrap,transformer oil empty drum o/u scrap
Tender For corrigendum : supply and installation of 03 nos. high mast light and 08 nos. 25 kva transformer on 11 mtr. sp 55 pole for energizing existing street light network at ia. mg. road hapur.
Tender For corrigendum : repair/replacement of insulators/ht vcb/rmu panels/maintenance of transformer and two pole structure and earth pits and allied works at af stn mothala under ge (af) naliya
Tender For rates for supplying and installation of below mention items inside kea premises, mysuru. - vcb panel - (outdoor type), supply, installation, testing & commissioning of outdoor cubicle type 1 panel 11 kv, 50 hz, ac rmu comprising of 1 no. 11kv, 21 ka, 630 a vcb for outgoing for transformer protection . as per eb/bescom requirement., transformer, "supply, erection, testing & commissioning of 1600kva,11/0.433kv, onan, copper wound oil cooled distribution transformer energyefficiency level-2 (as per is:1180 2021) with oltc & rtcc panel. with off circuit tap changer 5% to -15% in steps of 1.25% , plinth mounted type transformer as specified with cable box on both ht / lt side with all accessories as required for installation and properly grouted to the plinth with all accesories required for grouting. as per latest bescom", lt kiosk - (outdoor type), supply, installation, testing & commissioning of pole mounted weather proof enclosure comprising of 2500a 4p acb, suitable busbars for connecting cables, with provision for cable entry and terminations as per sld. the panel will be outdoor type suitalble for pole mounting. this item includes all necessary hardwares for mounting the panel on the pole (exclude the necessary civil works)., lt panels
Tender For corrigendum : supply of lt miscellaneous items for lt switchgear lt system for the year 2024-25 unit 5 and 6 csctpp chhabra - air flow sensor sl0101, control supply -230v ac, with 1 no +1nc contact, make-ifm or equivalent, dynamic braking resistor 13 ohms/ 9600w, 10% ed, 10 sec. max, ambient 50 degree,make-iresco/equi or equivalent, fan: axial, dia: 250, 230vac, 50hz, 115w, air flow:1610 m3/h (specification attached at annexure-i), fan: axial, dia: 450, 415 vac, 50hz,480 w, air flow:4530 m3/h,speed-1360 rpm,(specification attached at annexure-ii), fan axial 08" ball bring 230v ac 1p-50hz (as per annexure-iii ), relay assly : 4 relay, 2 c/o, 5a/24v dc, with led indication, iron core reactor 3 phase, 0.359mh/45a, 3 ph iron core, 117 uh/240a, make: rishab/ transformer/epi/equi or equivalent, 3 ph iron core, 67 uh/240a, make:rishab/ transformer/epi/equi or equivalent, 3 phase line choke ,in-21 amp,inductance-4.2mh,class-f,freq-50hz,voltage-415v, 3 phase line choke ,in-21 amp,impedance-3%,class-f,freq-50hz,voltage-415v, ct: metering 250/5a, 15va, class 1, ct dim.: 180{w}, 100{d}, 70{h}, window size:20x35mm, front terminals, resin, cast, insulation class:e, type 2, colour:yellow, resin cast insulaed c.t 400/5a,class-1,va-10, resin cast insulaed c.t 400/1a,class-1,va-10, thermal overload relay range 95-120 a, 125hp three phase submersible pump star delta starter with 3-position selector switch (with auto switch), single phase preventer, current overload protection with short circuit protection., aluminium ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, 35 sq.mm, 50 sq.mm, 70 sq.mm, 95 sq.mm, 120 sq.mm, 150 sq.mm, 185 sq.mm, aluminium pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 10 sq.mm, 16 sq.mm, 35 sq.mm, copper ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, power terminals mounting on din conforming iec 60947-7-1,voltage rating-1 kv,safe for fingers., current rating-140 a, 35 sq.mm,3 nm, current rating-192 a, 70 sq.mm,6 nm, current rating-232 a, 95 sq.mm,6 nm, copper pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 1.5 sq.mm(hollow type), 2.5 sq.mm, 2.5 sq.mm(hollow type), 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, copper u type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, terminals blocks (melamine housing) khaki color, 4 sq. mm, 32 amp., 600v, 10-20awg, screw type, din mounting, 6 sq. mm, 41 amp., 800v, 08-20awg, screw type, din mounting, 6-35 sq. mm, 125 amp., 750v, screw type, din mounting, 1.5-4sq. mm, 32 amp., 800v, 08-20awg, stud type, bolt connection, clip on din mounting, 35-50sq. mm, 125 amp., 1000v, clip on din mounting, wago make grey colour screwless , spring clamp, polyamide terminals for interpanel wiring , terminal:769-251, female plug:769-102 with add-on, modular timing relay,5a,2co,0.1s 100h,on-delay,230v ac, voltage-transducer, suitable for 24v dc power supply,i/p:0-500v ac,dual o/p(4-20ma), din rail mounted,, shunt resistor, 750a/60mv,0-60mv, shunt resistor, 175a/60mv,0-60mv, shunt resistor, 200a/60mv , 0-60mv, thermal overload relay,1.6a-2.5a, 3 pole, bi - metallic, 1 no + nc,, thermal overload relay,16a-25a, 3 pole, bi - metallic, 1 no + nc,, ac axial fan230 vac,50/60 hz 6"172x150x51 mm(model no rec-21725b2w) rexnord make or equivalent for 1:1 replacement, ac axial fan230 vac,50/60 hz 4"120x120x38 mm(model no rec-22038 a2t) rexnord make or equivalent for 1:1 replacement, transformer protection relay,i/p-4 nos of rtd sensors(pt-100),3 no of set points,0-300 temperature indication range,o/p-four relay contacts(01 c/o contacts),one analog 4-20 ma output contacts ,aux supply -90-270 v ac/dc,pecon make ,model no-tr-7570 or equivalent for 1:1 replacement, add-on auxilia