Tender For e tender supply, installation, testing and commissioning new display unit for online ambient air quality monitoring at gate no.7 and camc 6 yrs
Tender For procurement of hvac items components and accessories at acem under emu r and d nasik - d scaling for chemical, chemical, top up the gas in the refrigent working/non-functional units after pressure testing, vacuum testing, and leak testing up to required pressure and flow rate to maintain temperature etc. complete of split window/ vrf/ compressor unit of various ratings., providing & supply following field devices as per directions of engineer-in-charge., valve actuator. 50mm, level switch, float valve, thermostat, temperature sensor, pressure gauge, temperature gauge, expansion valve, volt meter, ammeter, selector switch, air dryer, indicator, compressor oil, providing laying, testing & commissioning of c class heavy duty ms pipe conforming to is 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per is 10221, refilling the trench etc. of following sizes complete as required., 80mm, 65mm, 50mm, 40mm, providing & supply following refrigerant copper tube & nitrile insulation as per directions of engineer-in-charge., 1 copper tubes, copper tubes, copper tubes, 3/8 inch copper tubes, providing & supply globe valves as per directions of engineer-in-charge., 125 mm (5"), providing & supply check valves as per directions of engineer-in-charge., 75 mm (3 "), providing, fixing and supply following size y strainers as per directions of engineer-in-charge., 50 mm (2"), 65 mm (2. 1 2 "), providing, fixing and supply following size pot strainers as per directions of engineer-in-charge., 100 mm, providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) :, 25 mm (1"), providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete :, 15 mm, 20 mm, 25 mm, providing and fixing gun metal non- return valve of approved quality (screwed end) as per directions of engineer-in-charge., 65 mm, providing, fixing and supply following electrical accessories as per directions of engineer-in-charge., mccb 100a / 415v / 50hz make and model as per existing system required., mccb 200a / 415v / 50hz make and model as per existing system required., sfu 63a / 415v /50hz fn 63 as per suitable in existing panel, sfu 32a / 415v /50hz fn 32 as per suitable in existing panel, motor protection relay range 0 - 20a/240v/50hz make minilec for existing panel, plc card, three phase monitoring relay, mod motor ll sensor, vfd 3.7 kw motor
Tender For corrigendum : epcc package for design, engineering, manufacture, transportation, installation, testing, commissioning and performance guarantee test runs of ethylene purification unit and ethylene drying and co2 removal unit to produce impact and random co polymer
Tender For supply, installation, testing and commissioning of 3 hp submersible pumping unit and repairing of damaged submersible pumping unit and rewinding of its damaged motor allied works at water supply scheme, pahloo, brein nishat
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For corrigendum : supply, installation, testing and commissioning of d.g set, horizontal multistage pumping unit along with allied works and submersible pumping unit with electro-mechanical works for bore well no 105 under national mission on saffron
Tender For supply, installation, testing and commissioning of solar powered led street lights for area lighting at kamsarat water treatment unit, wimberlygunj under eandm division, apwd, prothrapur
Tender For supply, installation, testing and commissioning of solar powered led street lights for area lighting at bambooflat dam and water treatment unit bambooflat under eandm division, apwd, prothrapur