Get complete information related to latest Post Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Post Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Post Insulator Tenders.
Tender For supply of 750 kva , 415 v , 1500 rpm prime diesel generator set with radiator on common base frame with accessories,acoustic enclosure for 750 kva diesel generator set,990 ltrs fuel day tank with accessories,24 v , 360 ah battery bank with leads and stand,24 v dc float cum boost battery charger,fuel piping and accessories from day tank to engine,silencers and supports , exhaust piping , stack , insulation and cladding including support structures as per cpcb norms,dg amf panel with air circuit breaker,dg auxiliary distribution board,alternator terminal box with extension busbars,non segregated phase busduct from alternator to dg amf panel,interconnecting power or control or instrument cables with glands and lugs,lube oil and pre- mixed coolant for 750 kva dg to be supplied at the time of commissioning,b- check kit for the engine of 750 kva dg to be supplied prior to commissioning.,tools and tackles for offered diesel generator set,supervision of erection of 750 kva diesel generator set,supervision of commissioning and load trial of 750 kva diesel generator set,total freight charges for a
Tender For corrigendum : procurement of dewatering pumps and its accessories to dewater the water of shahpurkandi hydel channel - submersible dewatering pump, make-mody pumps, model-g802t,25hp/18.65kw/3ph/50hz/415v/ 2850 rpm. features*tandem tc/tc & tc/tc mechanical seal, *6 hose ss outlet, insulation class h *ss410 hardened impeller *ss431 shaft, ss304 strainer & hardware *water proof/oil proof pvc cable 50 mtrs. (4c*6.0 sq.mm+2c*1.0sq.mm), dol control panel for 25hp/double door canopy typepanel with standard accessories mcb, ammeter ,voltmeter etc duly wired & painted), supply of ms pipe 150 mm (c class) 6 mtr length, supply of ms bend 150 mm (c class), supply of flanges 150 mm (c class), supply of nut & bolt, supply of rubber sheet flange
Tender For corrigendum : work contract for supply and application of pad quilt type ceramic fibre pad blanket insulation on bhel make kwu design 600 mw, hp and ip turbine modules and associated stop valves and control valves of unit-1 at 2x600 mw,sstpp,mppgcl, dongala
Tender For supply of 5.5t air conditioning w/ ductable unit with installation and accessories - 4854523, 1.000, *all the items with all accessories installation,testing and commissioning.*installation charges of ductable ac 5.5 tr with n2 (nitrogen) testing.*supply of refrigerant gas r-410.*lifting, shifting of machines.*transportation & mobilization.*all the accessories like (copper pipe,pvc pipe,cable etc) installation proper fitting neatly and in good condition of ss cable tray., 124540, 1.000, *supply & installation of control and transmission wiring between indoor and outdoor units -make - polycab/finolex.*communication cable for ac, size - 2.5 sq mm x 8 c.*material unit -rmt., 110077, 15.000, *supply of pvc drain pipe with installation.*s.i.t.c of drain pipe.*s.i.t.c of pvc pipe 32 mm.(suitable for minimum 10kg/sq cm working pressure).condesate drain pipe insulated with closed cell nitrile rubber insulation).material unit -rmt.*make -astral, 120484, 1.000
Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For supply of rectifier-oil cooled 300a100v with digital indication and dimmer , pp tank 610x610x610mm with 150mm leg support inch drain nipple , rtd sensor and controls for anodizing and chromic acid , 100 lpm cartridge filter for anodizing and cadmium bath , anodizing bath chiller - capacity 1300 litre- 2 tr , caustic tank -naoh- 1200x920x920mm with heater and controls - ss 316 thickness 3 mm , caustic tank -naoh- insulation , tabletop ph meter with control sensor , hydrometer
Tender For supply of ex-work supply for 420 kv 1 phase bus postinsulator except for line traps , ex work supply for 245 kv 1 phase bus postinsulator except for line traps , ex work supply for 145kv 1 phase bus postinsulators , ex work supply for 420 kv 1 phase bus postinsulators for line traps , ex work supply for 245 kv 1 phase bus postinsulators for line traps , ex work supply for 420 kv 1 phase bus postinsulator polymer type except for linetraps , ex work supply for 245 kv 1 phase bus postinsulator polymer type except for linetraps , ex work supply for 145 kv, 1 phase bus postinsulator polymer type , frieght and insurance for 500 km for 420 kv 1 phase bus postinsulator except for line traps , frieght and insurance for 500 km for 245 kv 1 phase bus postinsulator except for line traps , frieght and insurance for 500 km for 145kv 1 phase bus postinsulators , frieght and insurance for 500 km for 420 kv 1 phase bus postinsulators for line traps , frieght and insurance for 500 km for 245 kv 1 phase bus postinsulators for line traps , frieght and insurance for 500 km for 420 kv 1 phase bus postinsulator polymer type except for linetraps , frieght and insurance for 500 km for 245 kv 1 phase bus postinsulator polymer type except for linetraps , frieght and insurance for 500 km for 145 kv, 1 phase bus postinsulator polymer type