Get complete information related to latest Potential Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Potential Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Potential Analyzer Tenders.
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - total price including all applicable taxes and duties for biennial rate contract for vibration monitoring and analysis of rotary equipment for finding root cause of t..
Tender For corrigendum : supply of eye tracker with data analysis software : :--eye tracker with data analysis software with 01 year warranty , 02nd year warranty cost of equipment , 3rd year warranty cost of equipment , 04th year warranty cost of equipmen , 05th year warranty cost of equipment , desktop computer
Tender For corrigendum : tender for supply, installation, training and commissioning of particle size (dynamic light scattering) and zeta potentialanalyzer (electrophoretic light scattering) with three years onsite all inclusives comprehensive warranty period - tender for supply, installation, training and commissioning of “particle size (dynamic light scattering) and zeta potentialanalyzer (electrophoretic light scattering)” with three years on-site all inclusives comprehensive warranty period as per the specifications attached in section - 3.
Tender For corrigendum : providing of testing service for on-board /commissioned equipment/ instrument related to plant - chemical; chemical analysis; nabl labs
Tender For corrigendum : supply of procurement of sports science non consumable equipment c c - combination therapy , high power laser therapy , extra corporeal shock-wave therapy , cryoflow cryotherapy machine , portable metabolic monitor with ergocycle , gait and squat analysis system , smf-bia body composition analyzer , multi gym for para athletes , seated leg press machine , power rack
Tender For providing of custom bid for services - calibration by nabl accredited of equipment apparatus for the period 17 01 2026 to 17 01 2029 3 years to be performed each year installed at area coal analysis laboratory balgi project
Tender For corrigendum : supply of procurement of automated spectrum management system solution : : - design, development, deployment of technical analysis module, customization of the software, uat and security audit , design, development and deployment of integration with saral sanchar or any other portal of dot , design, development and deployment of integration with monitoring equipment , training-1 , training-2 , miscellaneous
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque