Get complete information related to latest Potentiostat Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Potentiostat Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Potentiostat Tenders.
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For corrigendum : purchase of equipment - equipment - electrochemical cables, descriptionto procure electrochemical cables compatible with an existing origalys electrochemical workstation (potentiostat/galvanostat).technical requirements mandatory requirement: the cables offered must be 100% compatible with origalys potentiostat/galvanostat systems, specifically the origaflex series. connector type: the cable assembly must feature the specific circular connector, required to connect directly with the origalys channel board.electrical specifications current rating: cables must support a maximum continuous current of at least 1 a voltage rating: insulation and connectors must be rated for a compliance voltage of at least 20 v.cable configuration the cable assembly must have 4-electrode:working electrode (we), counter/auxiliary electrode (ce/aux), reference electrode (ref) warranty & support minimum 1-year warranty on the electrochemical cables.
Tender For corrigendum : purchase of equipment - equipment - screen printed carbon electrodes (spce), descriptionto procure screen printed carbon electrodes compatible with sensit bt hand held & dual channel potentiostat from palmsens.technical requirements electrode configuration working electrode: carbon reference electrode: ag/agcl counter electrode: carbon dimensions: 0.8 x 4.5 cm working electrode dimensions: 7.06 mm we diameter 3 mm substrate: polyester thickness: 200 m contact pad pitch: 2.54 mm coefficient of variation (cv) (n = 9): 3 %
Tender For corrigendum : supply installation and commissioning of high temperature electrochemical cell with multichannel (2 channel) potentiostat galvanostat