Tender For supply, installation testing and commissioning of behavioral lab comprising of open field test, mouse novel object recognition, water maze - total price for the bom of imported item(s) quoted in foregin currency by you in technical bid, total price for the bom of locally supplied item(s) quoted in inr by you in technical bid
Tender For upkeeping and providing caretaking services, washing/dry cleaning of furnishing and mess facilities at cpwd guest house, japorigog colony guwahati 781024 during 2025-26.( sh: supply, installation, testing and commissioning of electrical and electronic item for cpwd guest house).subwork/packages:sitc of electrical and electronic item for cpwd guest house
Tender For supply, installation and testing of networking item aruba 2930 f 48 g , commscope yellow cat 6 patch chord 1mtr rack side , commscope yellow cat 6 patch chord 2mtr user side , commscope cat 6 jack panel unloaded , commscope utp cat 6 cable box , commscope cat 6 information outlet , commscope single port face plate , multi-mode fibre 6 core , hdp pipe , hdp pipe laying charges , digging of soil , splicing charges , 1 g sfp mmd , commscope liu 6 core , fibre patch cord 1m lc to lc , pvc saddle , gypsum black screw 1 inch , pdu , gang box , velcro tie , cable tie , hardware , conduit pipe 25 mm isi mark (with accessories) including laying charges , cable ferrule (0 to 9) , flexible pipe white 40 mm including laying charges , labour charge (for cable laying & termination of i/o) , rack installation and dressing , rack 9u with glass door, lock & key with hardware, with fastener or (if any material required for fixing)
Tender For corrigendum : supply, installation, testing & commissioning of ip based video surveillance system etc. (detailed description as per item description)
Tender For provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, powerfactor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & nuts etc as req
Tender For supply of accessories and installation of split acs e e - dismantling of existing hiwall split acs of capacities one tr and one point five tr , dismantling of copper refrigerant piping of the item sl no 1 , dismantling of existing ceiling suspended type split acs of capacities one point five tr , dismantling of copper refrigerant piping of the item sl no 3 , dismantling of existing hi wall split acs of capacities two tr , dismantling of copper refrigerant piping of the item sl no 5 , installation testing commissioning of existing new one tr capacity hiwall split ac , installation, testing, commissioning of existing new one point five tr capacity hi-wall split , supply installation testing commissioning of refrigerant copper piping for item sl no 7 and 8 , installation testing commissioning of existing new one point five tr capacity ductable split ac , supply installation testing commissioning of refrigerant copper piping for item sl no 10 , installation testing commissioning of existing new one point nine tr capacity hi wall split , supply installation testing commissioning of refrigerant copper piping for item sl no 12
Tender For testing of electring equipment at 11/6.6 kv kantapahari sub station under akwmc katras area - item description / headling, high voltage test of breaker, high voltage test of 5 mva,11kv/6.6 kv power transformer, high voltage test of 3 mva,6.6 kv/3.3 kv power transformer, high voltage test of 2.5 mva,6.6 kv/3.3 kv power transformer, transformer test(ir,pi,dar,polarity,bdv & acidity of oil), transformer test( winding resistance,ratio,vector group magnatising current,magnetic balance, high voltage test of 11 kv grade cable, protection relay test by primary current injection, auxiliary relay test(over/under/master trip etc.), testing of earth pit, total impact of gst for the purpose of ctc
Tender For corrigendum : supply of gas chromatography instrument with tcd- methanizer fid. - supply installation testing and commissioning of gas chromatography instrument with tcd-methanizer fid, gst on item, packing & forwarding, gst on packing & forwarding, gst on installation, commissioning and training charges, any other charges
Tender For custom bid for services - 9040c25d03 annual rate contract for in situ machining of various equipments at haldia refinery-00010 cme10051xx in-situ flange machining of flanges (all types) charges to carry out in situ machining of gasket face flanges (all types of flanges) of heat exchanger/ pipe/ pipe fittings/ column manhole/ reactor manhole/ vessel manhole/ or any other equivalent equipment with skilled manpower & suitable equiment/ machinery. job includes supplying of all types of tools and tackles, jigs and fixtures, lifting arrangements, electrodes, welding equipment, pmi machine, machineries, all consumables, labour etc. and supervision to complete the work in all respects as per drawings and direction of the engineer-in-charge, including area preparation, taking clearance for hot jobs, area cleaning after completion of work, flushing wherever required. the scope includes all necessary jobs (including weld buid up) required to restore the flange face finish as per asme b16.5/ b16.47 as per drawing specifications. the machined surface flatness and/ aarh, as applicable, is to be maintained as per prevailing codes and standards. contractor to identify the flange metallurgy for electrode selection required for weld build up. contractor has to execute weld build up jobs under the inspection of inspection department iocl refinery. after completion of work, the flange has to pass through pressure testing. unit of measurement "inch-dia" denotes inch-dia of the circular / oval flanges. in case of oval flanges, the measurement highest flange dia of a particular flange will be considered., 00020 cme1005101 in-situ flange machining of flanges (all types), 00030 cme1005102 mobilisation and demobilization charges, 00040 1,856,238.- round the clock/ shutdown factor: for shutdown/ breakdown/ emergency jobs, where the jobs are required to be continued round the clock, a multiplication factor of 25% shall be adopted on rfq item 10 comprising of m&i common mechanical, instrumentaion & electrical sor items (item nos. starting with cme, cin & cel)., .