Get complete information related to latest Power Plant Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Plant Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Plant Repair Tenders.
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal powerplant; repair re babbitting and regeneration of tg bearing 1 dia 250x180mm and re babbitting of thrust pads of journal cum thrust bearing of 250 mw kwu tur..
Tender For providing of operation and maintenance power house / powerplant - repairing overhauling of 11 kv cg and jyoti ltd make vcb with bus duct and routine upkeeping of natural vegetation sprinkler watering system etc of 33 11 kv substation at colony of ptpp pari..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal powerplant; repair/rectification and attending boiler tube leakage, shielding of pressure parts tubes in 2nd pass of boiler and other miscellaneous works of mai..
Tender For providing of operation and maintenance power house / powerplant - repairing of dpu mr card valmet make,operation and maintenance power house / powerplant - emergency repairing of dpu mr card valmet make,operation and maintenance power house / powerplant - maxdna valmet or metso modules repair like digital input module digital output module analog input module analog output module relay output module tc mv input module etc
Tender For corrigendum : tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for pfc and tri