Web Analytics Made Easy - StatCounter

Power Transmission Tenders

Get complete information related to latest Power Transmission Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Transmission Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Transmission Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41029380 Due date: 24 Jul, 202524 Jul, 2025 NA
Tender For supply, installation, testing and commissioning of router for 1 gbps ill connectivity at power transmission corporation of uttarakhand limited, dehradun

CTN :40710102 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For corrigendum : appointment of consultancy firm for jammu and kashmir power transmission corporation limited (jkptcl) for preparation of multi year tariff petition and other regulatory compliances.

Central Government And Public Sector

CTN :41010897 Due date: 31 Jul, 202531 Jul, 2025 NA
Tender For supply of servogem 3 / lithon-3/ balmerol liprex ep-3 , servo transmission c4 sae 10w/hp power glide c- 4 10/poweroil transmission c4 sae 10w

State Government

CTN :40985778 Due date: 28 Jul, 202528 Jul, 2025 1.80 Crore
Tender For purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum 7 high resolut

State Government

CTN :40985783 Due date: 28 Jul, 202528 Jul, 2025 1.50 Crore
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
 Loading, Please wait...

Connect us via What's Up