Web Analytics Made Easy - StatCounter

Power Ascender Tenders

Get complete information related to latest Power Ascender Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Ascender Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Ascender Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45717107 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For tender for repair of cots automatic identification system view control panel and display non functional

CTN :45195412 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : supply of automatic microbial identification and susceptibility testing system

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

CTN :45451439 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For corrigendum : supply of repair of cots automatic identification system view control panel and display non functional

CTN :44926065 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of battery operated power ascender (defence) (q3)

CTN :45361720 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For corrigendum : supply of automatic identification system-n5840-003855 , fleet broadband 500-n5895-022259 , non linear junction detector/super broom advanced-n5895- 021633

CTN :44960163 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : supply of battery operated power ascender (defence) (q3)

CTN :45580219 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For providing of repair and overhauling service - potable water purification system reverse osmosis or uv based; repairing of reverse osmosis; yes; buyer premises,repair and overhauling service - wheeled skid steer loader (v2) as per is / iso 7131 (latest); repairing of skid loader; yes; buyer premises,repair and overhauling service - cars; repairing of boat; yes; buyer premises,repair and overhauling service - diesel generators- dg sets; repairing of 10 kva gen sets; yes; buyer premises,repair and overhauling service - split air conditioner including green ac; repairing of ac; yes; buyer premises,repair and overhauling service - cars; repairing of cooler; yes; buyer premises,repair and overhauling service - cars; repairing of power ascender and under water sonar; yes; buyer premises

Central Government/Public Sector

CTN :45551234 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For supply, installation & commissioning of odysse power ascender/descender-pmx (petrol version) with transportation box & user manual- 01 each, make- acstafe as per details description & specification given below-(1) rope- 10.5- 11 mm static/semi- static- en1891a. (2) safe working load (swl)- 250 kg. (3) ascent speed- 0-17m/min with 100 kg load. (4) descent speed- user regulated (maximum descent speed 30 m/min). (5) max. continuous descending distance- 150m. (6) temperature range- 20 degree c to + 40 degree c. (7) range- 750 m with 100 kg load. (8) weight- 13 kg (excluding box & fuel). (9) dimensions- 29 x 28 x 49 cm. (10) engine- honda gx35. (11) displacement- 35.8 cc. (12) fuel- unleaded petrol 91 octane or higher. (13) fuel tank- 0.65l. (14) engine oil- sae 10w-30. (15) noise level- 89 dba. [ warranty period: 30 months after the date of delivery ] ]

CTN :45260354 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For bid to ras bid to ras supply of automatic identification system
 Loading, Please wait...

Connect us via What's Up