Tender For corrigendum : supply of set of ioh kit for overhauling telpro-el (metallic) type spm aal part no. 3400007500/1, each set consists of 04 items and set of ioh kit for overhauling of aal make pulse generator aal part no. 1900007300/01 consists of 08 items as per attached annexure [ warranty period: 30 months after the date of delivery ] ]
Tender For digital speedometer and pulse generator set of 110v dc wall mounted with measuring rangeof 0.0 to 199.9km/hr along with test and calibration certificate. one set consist digital speedometer 1 no., pulse generator (pg) 01 no., connector cable 1.5mtr, 4 core 0.5 sq mm wire 12 mtr, junction box with connector 1 no, user manual.1 no. make /brand : sonata, b-mac, medha servo drives, laxven,autometer. material to be procured from oem or authorized dealers only. (one sample may be shown to consignee for confirmation of fitment before supply.) [ warranty period: 30 months after the date of delivery ] ]
Tender For purchase of ece practical equipments - equipments for ece practices:, single output regulated dc variable power supply input voltage: 230v / 50hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display, function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc/ 15 v dc, 200 ma regulated power supply. solderless breadboardwith minimum 840 tie-points,power distribution buses. zif (zero insertion force) ic socketsto accommodate 8 or 16 pinics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., fpga trainer kit must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usbuart bridge, usb cable. user manual.
Tender For procurement of lab equipment for electronics and communication engineering department. - procurement of lab equipments for electronics and communication engineering department., function (signal) generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion: 1% (within acceptable range of frequencies). power supply: ac 220 v 10%, 50-60 hz output amplifier protection: protected against short circuit and 15v overload, digital storage oscilloscope bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 100 ns/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent basic trigger functions, embedded trainer kit (using lpc2148)cpu - lpc2148, core - 16/32 bit arm7dmi-s speed - max 60 mhz, flash - 512kb, ram (on-chip) - 40kb, 46 general purpose i/o. pins, usb2.0 one 10bit a/d converter with 14 analog inputs, one 10bit d/a converter, six pwm & watchdog two uarts (16c550), two i2c (400kb/s), two spi s eight bit digital output, eight bit digital input, 16 x 2 characters lcd and 4x4 matrix, keypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motor, driver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connector, and usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board example programs in embedded c and assembly with documentation (soft copy) power chord, user manual with cd/dvd, free demonstration after delivery
Tender For supply of head up tilt test hutt , 10 multipara patient monitors with central monitoring station and remote viewing , ivus and nirs , high end echo machine with tee probe and 3d echo , pulsed field ablation console with 03 complete catheter kit , oct , orbital atherectomy - oad pump with 10 complete catheter kit , rota ablator , ambulatory blood pressure monitoring , treadmill test equipment , 48 hour holter machine , single chamber temporary pacemaker pulse generator , pft - pulmonary function test machine , 12 lead ecg machine , defibrillator , echo cardiography scanning machine (v2) (q2)
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiac resynchronization therapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For lcd 8.4 inch a61l-001-0231s make fanuc , pendent type manual pulse generator a860-0203-t013 make fanuc , fan adaptor pcb a20b-8002-0998 make fanuc , cable a660-2007-t984l270r0 make fanuc , lcd panel a02b-0319-d021 make fanuc , 02 fan adaptor pcb, a20b-8003-0012 make fanuc
Tender For supply of ioh kit for overhauling of pulse generator of m/s aal make speedometer. type:- telproel (0-180 kmph), aal part no :- 1900007300, one set consisting 08 items, 31 nos. for ac electric locomotives. kit details as per annexure. [ warranty period: 30 months after the date of delivery ] ]
Tender For e-tender for rate contract for supply of lifesaving permanent implant product (item), for lifesaving cardiac operations and cardiac procedures (adult, paediatric & neonatal) i.e. pacemaker, pulse generator and leads for u n mehta institute of cardiology and research centre (affiliated to b. j. medical college & nabh accredited) ahmedabad, gujarat, india.