Web Analytics Made Easy - StatCounter

Power Bar Tenders

Get complete information related to latest Power Bar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Bar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Bar Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :43127681 Due date: 31 Dec, 202531 Dec, 2025 5.02 Lacs
Tender For supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material

CTN :43092779 Due date: 19 Dec, 202519 Dec, 2025 4.03 Lacs
Tender For rep. of (a) power bare head assy. of idm30 drill, 852 and rel c-650d drill, 708 and (b) 04 nos. idlers, 02 nos. take up wheel and 01 no. take up axle of ekg5a shovel hmb562.(c) rep. of boom foundation eyes etc. of ck300 (d) 758 of urimari ocp.

State Government

CTN :42756413 Due date: 22 Dec, 202522 Dec, 2025 NA
Tender For corrigendum : purchase of biomechanical equipments - isokinetic dynamometer (pac), should be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric , eccentric, concentric , and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees. should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda

CTN :42998045 Due date: 22 Dec, 202522 Dec, 2025 NA
Tender For supply of spares for battery charger c c -sc210050003 electronic scr control card, static type, avracr, card no-137-3p-fc , sc210030229 electronic scr control card, avr-acr module,static type, card no - m19 , sc210060079 thyristor, 475 amps, 800 volts, hsn code85413010 , sc210060082 thyristor, 45 amps, 800 volts,hsn code-85413010 , sc210060077 dcps for announciation , idsr static type, 24 v and 12 v dc , sc210060081 filter capacitor, suitably designed for specified ripple, hsn code- 85322200, 4700 mfd-350v dc , sc210060084 filter capacitor 1000mfd-350v dc, hsn code-85322200 , sc050410071 auxiliary relay for auto equalising, 110v dc, 3 co
 Loading, Please wait...

Connect us via What's Up