Get complete information related to latest Power Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Box Tenders.
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging
Tender For supply and installation of various electrical equipments in place of burn out and damaged ones at different panels and allied works at shanagar burning ghat. - supply and delivery of mccbs with thermal magnetic release breaking capacity thermal release rang 125-160a, breaking capacity icu at 415v ac, 50hz, 50ka4pole , supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range: 24-40, mn2, , powercontactors: supply and fixing the power contactor t.p 70a, l & t make (ml-4) having 240v, 50hz, coil incl. 2 no + 2 nc aux contact block., , powercontactors: supply and fixing the power contactor t.p 16a, l & t make having 240v, 50hz, coil incl. 1no+1nc aux contact block., , supply & fixing of 415/440 volt, hrc fuse (make: l&t/havels/cgl/ge).for 250 amp supply and fixing of analog ammeter ranging 0-100amps having c.r ratio of 100/5a, 144 mm sq size (make: ae/kappa/mp)., , supply and fixing of analog voltmeter ranging from 0-500 v of 144 mm sq size (make: αε/καрралмр)., , supplying and fixing 415v, tpn sfu open execution in existing ss enclosure/cubical with nuts bolts etc incl. s & f 3 nos. din type hrc fuse as per rating. 125a siemens, , supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection legrand 63 a fp, , supplying of 1.1 kv. grade pvc insulated conductor of following cables (make: polycab/gloster/havells/):size in sq. mm, no & dia. of wire in mm, no of core - 4 1/2.24 3, , annexure - i basic rate of materials: (all rates of materials from k-1 to k-14 are excluding vat) 70.1.5 sq.mm 'fr' stranded copper wire, , compression glands.supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture(proof entry of xlpe/pvc armoured cables as below: for, , 3 core.(i)upto 4 sqmm, , finishing cable ends.(b)finishing the end of following xlpe/pvc, , armoured cables by crimping method incl. supplying and fixing solderless socket (dowels make), tapes, anticorrosive paste & jointing materials. (ii) 2 core 6 sqmm cable, , temperature controller: a) supply and fixing the digital type temperature controller of range (0-1200) deg. c of overall dimension 92 sq mm dia x 105mm depth having (cr-a1) heat sensor and 1 no + 1 n.c change over contact to be actuated at crossed of desired temperature in deg.c complete power supply unit of 230v 50 hz., , blue max make
Tender For tender for supply of sicop power contactor 32a siemens , sicop power contactor 38a siemens , sicop power contactor 38a dc coil siemen , powercontactors 2no 2nc 3rt25 ac coil , sicop power contactor 45adc coil siemens , sicop power contactor 63a 30kw siemens
Tender For supply of set of ltc contactors consisting of two items 1:ltc line contactor as per medha part no sp675201200 having qty. 1 no. 2:ltc pre charging contactor as per medha part no sp675201208 having qty.1 no [ warranty period: 30 months after the date of delivery ] ]
Tender For set of snap action micro switches for 3ph locomotives pre-charging contactors. oneset consists of 02 items in 02 nos. as follows. 1) micro switch type no s 846-1-20 to schaltbau pt.no. 1-1546-194116 or secheron pt no. hbta420574p0001 %u2013 01 no/set 2) micro switch type no.s845-1-20 to schaltbau pt.no. 1-1545-194558 or secheron pt no. hbta420574 p0002 %u2013 01 no/set. make:secheron or schaltbau or note:- firm should submit authorised dealership certificate along with the tender or proofof purchase from authorised dealer or oem at the time of supply. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]