Web Analytics Made Easy - StatCounter

Power Card Tenders

Get complete information related to latest Power Card Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Card Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Card Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45716079 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of gear motor , teflon slip , epson printer head , pressure roller brother , power card , teflon paper

CTN :45566060 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For bid to ras supply of hp d j 5075 printer head carriage assembly , hp mfp m176n imaging drum , brother mfd b7535 dw power card , brother mfd t4500 dw power card , acer all in one screen , epson 310 printer waste ink pad , epson 310 scanner cable

Central Government And Public Sector

CTN :45432696 Due date: 02 Jul, 202602 Jul, 2026 4.17 Lacs
Tender For corrigendum : supply of spares for repair of actuators of motorized valves c c - overload relay with base 4 to 6 a , motor 3 point 32 hp 2 point 43 kw 3 phase 2915 rpm , push button assembly for l120 40 , sbc card limitorque , power card for actuator model l120 40 , declutch shaft assembly for l120 40 , 20 core ribbon , compartment glass cover inspection window glass , thrust base assembly , contactor tc1d1810

State Government

CTN :45688381 Due date: 01 Jul, 202601 Jul, 2026 1.96 Lacs
Tender For letter no 164-65 computer and printers parts - ddr4 ram 8 gb with installation , epson mantainance box , cat 6 cable , d-link switch 5 port , nvme hard disk 512 gb , ddr4 ram 4 g.b. with installation , mini smps change with installation , epson printer head , hp printer pickup roller , printer cartage gear set , hp printer formatter card , d-link switch 8 port , laptop hdmi port , motherboard cpu fan , motherboard vga port , printer power card , led power adaptor , printer taflon , printer led panel , printer joins unit , printer paper motor , usb cable , hdmi cable , rj 45 connector , mother board lane port , hp printer m427 adf , led power card , d-pitch cod , ddr ram 16gb , hp 108a ground chip set , canon body change , mother board lane port , canon engine control , high voltage supply , hp pressure roller

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

CTN :45656776 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of hp alll- n one desktop model 440g9 aio intelcore i7 12th gen 16gb ram 512gb ssd led display 3 years hp onsite warranty , keyboard hp , mouse hp , power card , mouse pad

CTN :45657375 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of ups bty , oxygen flow meter , hemoglobin meter , power card 12v , solid state relay

CTN :45648522 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of power card online ups , dvd writer , ram ddr iv 8 gb , processor i5 12th gen , keyboard with mouse , power card online printer , mother board , processor i3 10th gen

Central Government/Public Sector

CTN :45664564 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of set of fire detection equipment cards consisting as follows. (1) display board for fdu pt.no.pi 6340.18, qty. - 01 no. (2) controller card for fdu pt.no.pi 6340.16, qty. - 01 no. (3) power card for fdu pt.no.pi 6340.14, qty. - 01 no. make/brand: trolex [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45263804 Due date: 01 Jul, 202601 Jul, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
 Loading, Please wait...

Connect us via What's Up