Tender For pre-wired t rosette strain gauge , pre-wired rectangular rosette strain gauge , adhesive for strain gauge , covering agent for strain gauge , strain gauge application kit , high temerature insulation tape , special high temerature adhesive tape aluminized , triad cable , push in connector for mx1615b daq , buffing machine , self adhesive thermocouple , k type female thermocouple connector , k type male thermocouple connector , k type thermocouple extension wire , cement for thermocouple and rtds , cold storage unit
Tender For tender for repairing and calibration of temperature indicators installed on boiler , work of repairing, calibration and rewiring of superheated wash water temperature control system , laying of comprehensive cable, installation of thermocouple and commissioning of indicators at the boiler station , work of repairing, rewiring, overhauling and commissioning of d- superheating system of exhaust line , repairing and commissioning work of temperature indicators of sulfur furnace , laying of compressive cables of sulfur furnace, installation of sensors and commissioning of temperature indicators , to carry out installation and commissioning work for raw-sulfated juice, clear juice, exhaust steam and injection water inlet temperature , over hauling, rewiring and recommissioning of auto drum water level control system of boilers , rewiring and recommissioning of high or low alarm system on boilers for water level , overhauling, rewiring and recommissioning of boiler steam generation system , overhauling, rewiring and recommissioning of boiler feed water measurement system
Tender For supply of spares for 100kn servo electric utms - limit switch for kappa 100ss-cf, p/n z108.057, limit switch for hydraulic adjustment, p/n z108.078, remote control for setting up inching operation, p/n mp02489, usc module kappa, universal measurement amplifier, for connecting resistive and inductive bridge sensors, choice of ac/dc power supply, 4 and 6-conductor technology, 24-bit calculated resolution, module occupies one module bus slot, p/n mp00525, insulation end disc half, ultiform uvs 144, p/n z551.004-014, heating element kanthal apm, id 5 in, length 4in, fur 1250 °c p/n z906.072, furnace insulation vertical plate, p/n z551.004-010, furnace thermocouple type s for 5" furnace incl. compensating cables, p/n z551.034, solid state relais 30a/660v for ht-controller 1200°c p/n 930.ssm1a130bd, moving iron instrument 0...5a/10a, p/n 930.eq48, power supply 24 v, p/n 930.2868635, contactor tesys 7.5 kw, p/n 930.lc1d18bl, extension cable hiperface for tcii, p/n 977.066342, external power supply 48v/10a, p/n z240.054-011
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin
Tender For maintenance of electrical installation and fans, repair and maintenance of p/set in cgs colony, kane nagar, mumbai-400037.sub head: supply, installation, testing and commissioning of led street light fixture and replacement of deterioted powerdistributioncable in navchetna building in sector 3.