Tender For corrigendum : tender for supply of fids and 05 years camc at srinagar airport : - supply of 3 x 2 mtrs. or higher true colour led display board with stainless steel floor ceiling wall mounting arrangement. , supply of 65 inch led display with floorceiling wall mounts as per the specifications , supply of 55 inch led display with floor ceiling wall mounts as per the specifications , supply of 43 inch led display with floor ceiling wall mounts as per the specifications , supply of fids servers to work as main and standby set of two servers with accessories as per the tender specifications. , supply of data entry terminal client desktop pc with all accessories as per the tender specifications. , supply of ntp server with accessories as per tender specifications. , supply of licensed operating system server level with support for all servers , supply of operating system at client level pc work station etc. with support for all clients , supply of licensed antivirus server level with support for all servers , supply of licensed antivirus client level with support for all servers , supply of layer 3 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of layer 2 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of 12v 84ah battery for the 2x 20kva ups of make numeric hp max. the cost of old batteries connected to ups shall be considerd while qouting and shall be handed over to contractor as buy back. , supply of fids package software as per requirement of the tender , supply of 8 port kvm switch. , supply and laying of 25 mm dia , 16 swg isi marked pvc conduit with accessories as required , supply and laying of 3 core 6 sq mm multi strand copper conductor pvc insulated pvc sheathed armoured power cable on wall surface tray with accessories as required , supply and laying of 3 core 1.5 sq mm multistrand copper conductor pvc insulated pvc sheathed unarmoured power cable in existing conduit tray with accessories as required , supply and laying of 6 core smf ofc unarmoured cable on wall surface tray with accessories as required , supply and laying of utp cat 6 cable in existing conduit tray with accessories including termination with wall surface mount box as required , supply of powerdistributionpanel complete as per specifications for flds system. , excavation soft digging back filling as per site requirement , supply of rj45 io face plate gang boxback box with standard length of patch cable for fid system as per site requirement and specifications , training and documentation as per tender , charges for installation testing and commissioning of the complete system including integration of existing 24 nos , cids with new fids system.
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For maintenance of electrical installation and fans including repair maintenance of compound light snd pump set of sepcial bureau office ,kankot, rajkot. sh: supply, installation, testing and commissioning of se-eom for amf panel, copper plate earthing for existing ups system and servicing andtesting for 11 kv transformer, ht panel.
Tender For annual repair and maintenance of complete substations (33/11 kv and 11/0.415 kv) including all transformer, lt panel, ht panel, rmu, feeder panel etc. for one-year at iit jodhpur campus.