Get complete information related to latest Power Factor Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Factor Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Factor Repair Tenders.
Tender For motor protection circuit breaker (mpcb) for condenser fan unit, current rating 1.6 to 2.5 amps, class 10,breaking capacity - 50 ka, 3 pole voltage rating 415 v ac, 01 no + 01nc auxiliary contacts for lhb ac switch board cabinet as per rdso spec no. rdso/pe/spec/ 0184-2015 rev 1or latest and rdso lr.no el/7.1.108/mssbc dt:17/09/2021. acceptable makes: siemens model.no. 3rv2011-1ca10+3rv2901-1e, l&t model.no. st418950000, schneider modelno. gv2me07, abb model.no ms116-2.5 and eaton model no.pkzm01-1.6+nhi-e-11-pkz0 only acceptable as per abovespec. warranty period: 30 months from the date of supply. [ warranty period: 30 months after the date of delivery ]
Tender For supply of over voltage protection (ovp) testing unit for 4.5 kw and 25 kw rrus and errus of tl/ac c oaches as per rdso smi no. rdso/pe/smi/tl/0047-2013 (rev.0) [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of lt miscellaneous items for lt switchgear lt system for the year 2024-25 unit 5 and 6 csctpp chhabra - air flow sensor sl0101, control supply -230v ac, with 1 no +1nc contact, make-ifm or equivalent, dynamic braking resistor 13 ohms/ 9600w, 10% ed, 10 sec. max, ambient 50 degree,make-iresco/equi or equivalent, fan: axial, dia: 250, 230vac, 50hz, 115w, air flow:1610 m3/h (specification attached at annexure-i), fan: axial, dia: 450, 415 vac, 50hz,480 w, air flow:4530 m3/h,speed-1360 rpm,(specification attached at annexure-ii), fan axial 08" ball bring 230v ac 1p-50hz (as per annexure-iii ), relay assly : 4 relay, 2 c/o, 5a/24v dc, with led indication, iron core reactor 3 phase, 0.359mh/45a, 3 ph iron core, 117 uh/240a, make: rishab/ transformer/epi/equi or equivalent, 3 ph iron core, 67 uh/240a, make:rishab/ transformer/epi/equi or equivalent, 3 phase line choke ,in-21 amp,inductance-4.2mh,class-f,freq-50hz,voltage-415v, 3 phase line choke ,in-21 amp,impedance-3%,class-f,freq-50hz,voltage-415v, ct: metering 250/5a, 15va, class 1, ct dim.: 180{w}, 100{d}, 70{h}, window size:20x35mm, front terminals, resin, cast, insulation class:e, type 2, colour:yellow, resin cast insulaed c.t 400/5a,class-1,va-10, resin cast insulaed c.t 400/1a,class-1,va-10, thermal overload relay range 95-120 a, 125hp three phase submersible pump star delta starter with 3-position selector switch (with auto switch), single phase preventer, current overload protection with short circuit protection., aluminium ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, 35 sq.mm, 50 sq.mm, 70 sq.mm, 95 sq.mm, 120 sq.mm, 150 sq.mm, 185 sq.mm, aluminium pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 10 sq.mm, 16 sq.mm, 35 sq.mm, copper ring type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, power terminals mounting on din conforming iec 60947-7-1,voltage rating-1 kv,safe for fingers., current rating-140 a, 35 sq.mm,3 nm, current rating-192 a, 70 sq.mm,6 nm, current rating-232 a, 95 sq.mm,6 nm, copper pin type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 1.5 sq.mm(hollow type), 2.5 sq.mm, 2.5 sq.mm(hollow type), 6 sq.mm, 10 sq.mm, 16 sq.mm, 25 sq.mm, copper u type terminal lugs conforming to is-8337/is-5082 ,iec-61238,for voltage rating 1.1 kv, 1.5 sq.mm, 2.5 sq.mm, 6 sq.mm, terminals blocks (melamine housing) khaki color, 4 sq. mm, 32 amp., 600v, 10-20awg, screw type, din mounting, 6 sq. mm, 41 amp., 800v, 08-20awg, screw type, din mounting, 6-35 sq. mm, 125 amp., 750v, screw type, din mounting, 1.5-4sq. mm, 32 amp., 800v, 08-20awg, stud type, bolt connection, clip on din mounting, 35-50sq. mm, 125 amp., 1000v, clip on din mounting, wago make grey colour screwless , spring clamp, polyamide terminals for interpanel wiring , terminal:769-251, female plug:769-102 with add-on, modular timing relay,5a,2co,0.1s 100h,on-delay,230v ac, voltage-transducer, suitable for 24v dc power supply,i/p:0-500v ac,dual o/p(4-20ma), din rail mounted,, shunt resistor, 750a/60mv,0-60mv, shunt resistor, 175a/60mv,0-60mv, shunt resistor, 200a/60mv , 0-60mv, thermal overload relay,1.6a-2.5a, 3 pole, bi - metallic, 1 no + nc,, thermal overload relay,16a-25a, 3 pole, bi - metallic, 1 no + nc,, ac axial fan230 vac,50/60 hz 6"172x150x51 mm(model no rec-21725b2w) rexnord make or equivalent for 1:1 replacement, ac axial fan230 vac,50/60 hz 4"120x120x38 mm(model no rec-22038 a2t) rexnord make or equivalent for 1:1 replacement, transformer protection relay,i/p-4 nos of rtd sensors(pt-100),3 no of set points,0-300 temperature indication range,o/p-four relay contacts(01 c/o contacts),one analog 4-20 ma output contacts ,aux supply -90-270 v ac/dc,pecon make ,model no-tr-7570 or equivalent for 1:1 replacement, add-on auxilia
Tender For supply of led based driver and assistant desk illumination lamp as per clw specn. no. clw/es/3/ 0042 alt.d technical specifications :- 1)operating voltage 18 to 30 v dc with normal voltage of 24 v d c. 2)high and low glow switch has to be provided. 3)the lamp unit shall have inbuilt reverse polarity, overvoltage trip, spike and surge protection. 4)mechanically the housing shall be as per clw spec. no. clw/es/3/0042 alt.d or latest. [ warranty period: 30 months after the date of delivery ]
Tender For supply of led based driver and assistant desk illumination lamp as per clw specn. no. clw/es/3/ 0042 alt.d. technical specifications : 1)operating voltage 18 to 30 v dc, with normal voltage of 24 vd c. 2) high and low glow swith has to be provided.3) the lamp unit shall have inbuilt reverse polarity, over voltage trip, spike and surge protection.4) mechanically the housing shall be as per clw spec. no . clw/es/3/0042. alt.d [ warranty period: 30 months after the date of delivery ]
Tender For purchase of protection system spares for power house of parbati-ii hep - reb670 main-ii busbar protection relay , resisitor unit for rxmvb4 trip relay, rxtma , trip circuit supervision relay, tsr, coil voltage: 220v&110v dc, 2c/o, article no.: in 352 001-as , high speed trip relay, rxms1 , pushbutton module for trip relay, rxt - pb unit in5396 3001 -ac , test switch, rxtp18 , test pin , bistable relay rxmvb4 (rk251 403-ah)-pb2ph , numerical relay with 50,51,51n,27u,64r protection, ctr:- -5a, 3 di & 5do , static relay mvapm32d1aa2001a operating voltage vn 110v ac , dc supply monitoring relay - vaa11yf8752ca , aux relay,aux voltage 220-250v dc,2no+2nc,reverse flag,vaa11yf7752ca , two element aux. relay,s/r type, 2no+1nc with h/r operation indicator per element - vaa21zg0750ba , bistable relay - mvajm14jb1002a1 , bistable relay- mvajm14jb1004a1 , tripping relay,mvajm25la1004a,16 no+4 nc,h/r flag,burden high , tripping relay with s/r contacts - vajs23zg1000aba , aux voltage 110-125/220-250v dc,2no+2co,reverse flag,flush mount, model no: vax31zg0750ba , trip coil supervision,1no+2nc, s/r , h/r reverse operation indicator per element - vax21zg8045bch , no volt relay, voltage rating 63.5 v, 50 hz , voltage dropping resistor - 3.3 k ohms / 35 watt with base plate , metrosil resistor- s1088 , metrosil resistor - 1196 , stabilising resistor 0 to 1000 ohms , 20hz generator for 100% stator e/f protection relay , band pass filter with built in voltage divider for 100% stator e/f protection relay
Tender For supply ofsignal conditioner card no. 1 scc1 for hassdac , supply of signal conditioner card no.2 scc2 for hassdac , supply of dual micro controller logic card no.4 for hassdac , supply of modem card suitable for cel make hassdac , relay driver card no.5 for hassdac , event logger card , dc-dc convertor card no.6 for hassdac , web detector each set consists of 2 nos. of tx and 2 nos. of rx coils , reset box for hassdac , deflector plates and hardware for mounting axle detectors , hassdac unit housing with mother board, without cards , vital relay box model vr-722 duly wired for hassdac , surge voltage protection device , signalx make mux
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum