Get complete information related to latest Power Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Light Tenders.
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh
Tender For procurement of material and hiring of labour for day to day maintenance of various electrical installations in municipal parks and buildings in ward 140 inderpuri under kbz - supply of 1.5 sq. mm isi marked, frls pvc insulated,single core copper conductor cable as required., supply of 4.0 sq. mm isi marked, fr pvc insulated, single core copper conductor cable as required., supply of 63 amps., 2 pole isolator as required., supply of 6 a, to 32 a, ratings, dp mcb, "c" curve, 10 ka breaking capacity as required., supply of 6a to 32 a ratings, sp mcb, "c" curve, 10 ka breaking capacity as required., supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:- 2x 6 sqmm, supply of xlpe insulated pvc sheathed al. conductor armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*10 sqmm, supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. (c) three phase 5.0 hp having discharge of 300 lpm approx. at 39 m head., providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. skilled labour", providing following labour for day to day maintenance of ward i/c required t&p etc. in one shift in a day on all working days (required maintenance material will be provided by department) as required as per terms & condition of the department (excluding parts) complete as required. 1. un-skilled labour", supply of led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy 120 135 lm/watt) of following body materials. - 45 watt
Tender For provision of new led street lights with allied accessories on existing poles at various dark spots in saidulajab ward no 160 under south zone - led street light fixture, powder coated pressure die cast aluminium body (system lumen efficacy >135 lm/watt). supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, frequency 50/60 hz, operating temp range -5 0c to 50 0c, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%,thd 10% as per iec 61000-3-2, p. f. 0.95, ip-66,ik-10, cri >70, under voltage and over voltage protection, emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitary) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation color matching)5, maximum power consumption should not more than the specified rating and fixture shallbe of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductorsingle core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 testreport and all testing required for led fixturesas per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge asper requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). 45 watt , supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc power supply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc power supply compact designeasy to operatethe instrument should have following technical specifications:dc power supply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc power supply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase powerlight indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: ac power supply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop
Tender For transformer oil filtration , replacement of transformer oil of 400kva, 6.6kv/433v power transformer at stacker reclamier-i,ii,iii,iv, overhaul of 3-phase, 11kv/415v, 2000kva power transformer , overhaul of power transformers at locations of s/r's-i&ii & replacement of failed 433v/415v 3-phase 4-wire power/ lighting distribution/welding /sm transformers of different capacities ,laying different types of power cable in marshaling yard, conveyor galleries, various locations and maintenance of earth pits as and when required in em/chp divison/dr.nttps from 01-04-2026 or from the date of commencement of work to 30-09-2026.
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins