Get complete information related to latest Power Line Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Line Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Line Laying Tenders.
Tender For corrigendum : bi-arc for the emergency restoration of power of 66kv,132kv & 220kv transmission line on tower and h-frame structure (re-invite).
Tender For establishing of 2x160mva, 220/110kv and 1x10mva, 110/11kv substation at chadchan (devar nimbaragi) in chadachan taluk, vijayapura district with kiosk based arrangement along with construction of associated 220kv transmission line for a distance of 29.628km and 110kv lines for a distance of 60.78km along with construction of 2 nos of 220kv terminal bays and 05 nos of 110kv terminal bays on partial turnkey basis, including supply of all materials/equipments (excluding supply of 1x10mva,110/11kv power transformer & 11kv switchgear), erection (including dismantling and civil works) of all materials/equipments, testing and commissioning
Tender For corrigendum : supply, installation, testing and commissioning of 33 kv,3 pole,3 phase gang operated air break switch for replacement of worn out/damaged 33 kv air break switch near store subdivision for 33 kv ljhp-peernia transmission line
Tender For supply of centralized audio power handling unit continuous duty operation multi load output compatibility , multi input signal aggregation console supports multiple low level and line level sources , electro acoustic output transducers , voice input support assemblies , interconnection and signal routing accessories , inline audio conditioning modules signal stabilization and tonal correction support , direct voice capture devices , cordless transmission system , on site system deployment and functional validation physical integration
Tender For additional work for modification of existing 132kv d/c transmission line from 132kv gss rvpn, baran to baran tss 2-phase into 3- phase under deposit work of railway
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys
Tender For corrigendum : construction of 220 kv dedicated line bay and 220kv d/c transmission line from 220/66 kv grid station igc samba to proposed 2x25kv samba railway traction sub station (smbx rtss)