Web Analytics Made Easy - StatCounter

Power Plant Repair Tenders

Get complete information related to latest Power Plant Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Plant Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Plant Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42129136 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For automotive transmission fluid for power steering

CTN :41700709 Due date: 13 Oct, 202513 Oct, 2025 NA
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - appointment of independent engineer for transmission scheme for integration of tumkur-ii rez in karnataka; energy (oil, gas, power, renewables); no; hybrid(as specified in scope of work)

CTN :41700714 Due date: 13 Oct, 202513 Oct, 2025 NA
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - appointment of independent engineer for transmission system for evacuation of power from potential renewable energy zone in khavda area of gujarat under phase-iv 7 gw part a; energy (oil, gas, pow..

CTN :41602577 Due date: 04 Oct, 202504 Oct, 2025 NA
Tender For bid to ras bid to ras supply of impact testing machine charpy and izod , digital torsion testing machine , digital spring testing machine , rockwell cum brinell hardness tester , universal testing machine , wheel balancing machine , abs system trainer , electric vehicle kit , diesel fuel supply system , mpfi, four stroke four cylinder petrol engine test rig with eddy current dynamometer , model of mpfi system , model of crdi system , metallurgical microscope , metallurgical cut off machine , polishing machine , spark test apparatus , tool maker microscope , magnetic v block , angle deckor with set of angle gauges , profile projector , screw thread micrometer , sine bar , gear tooth vernier , sand mix muller , hand rammer , pneumatic rammer , shaper , milling , power hacksaw , circle cutting machine , edge folding machine , foot shear machine , digital multimeter , portable digital power factor meter , dc regulated power supply , portable digital wattmeter three phase , analog multimeter , digital lcr meter , digital clip on meter , current transformer , potential transformer , digital earth tester , portable digital power factor meter, single phase , portable digital frequency meter , digital flux meter , analog megger insulation tester , digital megger insulation tester , variac single phase , variac three phase , stroboscope , synchroscope , single phase resistive load , three phase resistive load , sliding rheostat wire wound , lte mobile trainer kit , am modulaor demodulator kit , psk modulator demodulator kit , qpsk modulator demodulator kit , am transmitter kit , arduino kits with modules , trainer board to study the effects of negative feedback on the amplifier characteristics , trainer board of two stage transformer coupled amplifier , trainer board of two stage direct coupled amplifier , trainer board to study characteristics of class a amplifier , optical fiber splicing machine , optical time domain reflectometer , pcb etching machine , pcb drilling machine , oil fired tilting type furnace impact testing machine (charpy & izod) with maximum capacity= 300 j for charpy 168 j for izod maximum scale graduation = 2 j, digital torsion testing machine with maximum torque capacity= 100 nm and lc 0.01 nm, digital spring testing machine with maximum capacity= 100 kn measuring range = 0- 100 kn load resolution= 5 n resolution of piston movement= 0.1 mm, rockwell cum brinell hardness tester with manual load selection and automatic zero setting dial gauge, universal testing machine with max capacity 100 kn load range: 0 100 kn load resolution: 2 n ram stroke: 150 mm, wheel balancing machine with weight of rotor= 0.5-10 kg max. weight on each pedestal= 7.5 kg max. diameter of rotor over bed= 600 mm, abs system trainer with four two wheels with wheel sensors and abs hydraulic actuator (modulator) unit which is controlled by the on-board computer system (ecu)., electric vehicle kit with ev controller, motor used in electric vehicle, battery used in electric vehicle, on board charger dc to dc converter,ac complete kit, transmission system etc, diesel fuel supply system with training board tank, the fuel transfer pumps, filters, injection pumps and the injection nozzles., mpfi, four stroke four cylinder petrol engine test rig with eddy current dynamometer, actual working metallic model showing various parts of mpfi system, actual working metallic model showing various //bid details 2 / 58

CTN :42101977 Due date: 09 Oct, 202509 Oct, 2025 2.47 Lacs
Tender For dismantling, repairing, backfitment radiator assy and its foundation, power lift cylinder, drawbar side shift cylinder, repair/fabrication of gate lock, engine hood, mounting, guard, transmission guard, lhs rhs side panel, etc of bg825 g5 at aocp

CTN :42094969 Due date: 20 Oct, 202520 Oct, 2025 NA
Tender For supply of surveillance system phase i alongwith 04 x ptz camera c c - 32 ch nvr with 2 sata slot , 2mp ip ptz camera 30 x , 5mp ip bullet camera with 50 mtr ir , outdoor junction boxes with inbuilt pdus for media convertors oblique poe oblique adaptors etc , 04 plus 02 port poe switch , cat 6 cable twisted pair to enhance performance cable for transmission of high speed data comma digital oblique analog voice and video for outdoor use , 24 port gigabit switch non poe unmanaged switch 10 oblique 100 oblique 1000 , 16 port gigabit switch non poe , led hd tv 55 inch master control display unit , led tv 43 inch secondary display unit , optical patch cords , fiber splicing jointing kits , fiber terminal box 12f , 12 u rack fully loaded indoor , hdmi cable 5 mtr , optical fiber cable 12f optical fiber cable armoured , led tv 32 inch , 4 channel hd dvr , power cable 2 core 1 point 5 sqmm power cable , internal storage device 4 tb hdd , media convertor pair single mode and optical fiber media convertor distance greater then and equal to 20 kms , artificial intelligence box for 16 camera human intrusion detection , ups 3 point 2 kva with 03 nos 150 ah batteries tall tubular oblique flat plate lead acid batteries input voltage range 100 to 270 v ac , ms pipe oblique angles about 1 or 2 meter height for installation of bullet cameras , installation charges for all cameras oblique setting up of control room , ms poles 100 mm dia of 3 mtrs 75 mm dia of 3 point 5 mtrs above 4 mtrs total length of pole around 6 point 5 mtrs with grouting 0 point 600 into 0 point 600 into 0 point 900 mm pcc m20 grade

State Government

CTN :42036819 Due date: 06 Nov, 202506 Nov, 2025 NA
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp

Central Government / Public Sector

CTN :42098010 Due date: 14 Oct, 202514 Oct, 2025 NA
Tender For supply of 33kv power transmission cables

corporations/Associations/Others

CTN :41764049 Due date: 15 Oct, 202515 Oct, 2025 9.16 Lacs
Tender For corrigendum : bi-annual rate contract for providing and fixing of heat shrinkable cable termination kit suitable for 11 kv xlpe power cable indoor/outdoor (size 95 sqmm to 300 sqmm) for various s/s under bharuch transmission circle

State Government

CTN :42099912 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For office of the executive engineer electricity transmission division – gonda u.p. power transmission corporation limited 220 kv sub-station campus, jail road; gonda-271001.
 Loading, Please wait...

Connect us via What's Up