Get complete information related to latest Power Rail Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Rail Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Rail Tenders.
Tender For corrigendum : camc including consumables, repairs and replacement of defective parts of 1000 lpm ogp along with allied electro mechanical equipments along with operational charges for 01 year at gmc ah rajouri - comprehensive annual maintenance (camc) camc of oxygen generation plant ( airsep make 1000 lpm complete unit) which includes periodic servicing/maintenance and repairs of complete ogp unit (consisting of oxygen modules, air compressors (110 kw ingersoll rand make, air dryers (trident make), filtration assemblies, air tanks, oxygen tanks, interconnecting pipeline, control valves, indicators, sensors, pressure & purity meters, ups, electric panel, valve panel, and other allied accessories, etc.), (including topping/replacement of molecular sieve (zeolite/alumina/any other chemical as per requirement), copper pipeline from plant room upto patient beds, allied equipments such as main 630 amp. electric distribution cum changeover panel, mccbs/acbs, 400 kva avr (ae make), 250 kva avr (jaima make), 400 kva dg set sudhir power make (including replacement of batteries), amf panel, cabling, lightening arrestor, earthing, etc., other miscellaneous items of the plant room such as lighting, exhaust fans, ceiling fans, cctvs with inverter battery set, electric wiring and fittings, refilling of abc type fire extinguishers, other minor civil items, etc. the job also includes repair/replacement of defective pipeline from air compressors to air tanks/air dryers to psa tower in order to make it leak proof.the technicians for operation will be responsible for preventive maintenance, minor repairs/settings on a routine basis. major breakdowns of the plant equipment to be repaired by the firm through oems/open market workshops, etc. for maintaining the plant in working condition the firm will bear all charges of material including consumables, labour, transportation and all taxes as applicable.any other item of the oxygen plant not mentioned in the above description, but found necessary for the functioning of the plant, is deemed to be covered under the oc/camc contractfirst year, second year, third year, fourth year, fifth year, sixth year, seventh year, operational contract (oc)24x7 operation of 1000 lpm psa oxygen generation plant ( airsep make complete unit) and it s all allied equipments including power backup. the technicians for operation will also be responsible for preventive maintenance, minor repairs/settings on a routine basis. wages of the operators/technicians (3 nos + 1 no) for 01 year (12 months) having experience of similar work.first year, second year, third year, fourth year, fifth year, sixth year, seventh year
Tender For provision for the works for compliance of the observation by aviation safety at katihar. sub head- rectification or repair of ht panel, avr and provision of avr cum transformer and its associated works at katihar mssr station
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage