Get complete information related to latest Power Supply Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Supply Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Supply Cable Tenders.
Tender For supply of set of terminals for lead cable of traction motor type 1tb 2022 ota 03 of m/s. siemens as per drawing no. wr/mx/el-1898-3-ac-dc-tm-263 only. [ warranty period: 30 months after the date of delivery ]
Tender For supply of flow sensor ,24v dc input voltage, no/nc output programmable , item code si 5000 item details sid10abbfpkg/us-100-ifm flow sensor along with angle connector cable evc468-adoah043mss04.8h04 ifm 5m with led for above flow sensor for cnc machine line of asc. make:ifm. warranty: 18 months from the date of invoice. [ warranty period: 18 months after the date of delivery ]
Tender For supply of digital insulation tester features pi (polarization index) measurement autopower off battery power indication external connection to 12v/1a power s supply over load protection testtime function setting, automatically run the measurement within the specified time. specifications- rated voltage 500v/1000v/2500v/5000v ac/dc, measuring range-500v/1000m!, 1000v/2g!, 2500v/100g! & 5000v/1000g!, open circuit voltage-dc 500v +30%, -0% -dc 5000v +20%, -0%, including inbuilt lithium iron rechargeable 12 volt battery. packing-gift box accessories testing cable, lead, power adapter and etc. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia
Tender For corrigendum : supply of eil d d - e4953196 numerical relays 01-sg4950387111-numerical o_slash_c and e_slash_f relay for incomer_slash_tie_slash_bc as per annexure-a it-001 _50_slash_51_slash_50n_slash_51n_slash_25_ , 02- sg4950387120-numerical trafo protection relay as per annexure-a it-002 _50_slash_51_slash_50n_slash_51n_. , 03-sg4950387138- numerical o_slash_c and e_slash_f relay for capacitor feeder_slash_og as per annexure-a it-003. , 04- sg4950387146-numerical motor protection relay as per annexure-a it-004. , 05-sg4950387154-numerical motor differential _slash_ ref. protection relay as per annexure-a it-005 , 06-sg4950387162-numerical line diff relay as per ann-a it-006 , 07-sg4950387170- numerical motor protection relay with reverse power function as per annexure-a it-007. , 08- sg4950387189-numerical under voltage relay as per annexure-a it-008. , 09-sg4950387219-ethernet switches _24 cu plus 4 fo_ as per ann-a it-009. , 10- sg4950387227-cat-6 cable as per ann-a it-010. uom- meters , 11-sg4950387235-fo cable as per ann-a it-011. uom-meters , 12-sg4950387243-data concentrator panel as per ann-a it-012. , 13-sg4950387251-human machine interface _hmi_as per ann-a it-013. , 14- sg4950387278-relay parameterization device for dc as per ann-a it-014. , 15-sg4950387286-global positioning device as per ann-a it-015. , 16- sg4950387294-report printing device as per ann-a it- 016. ) /bid number : gem/2026/b/7405586 * /dated: 31-03-2026 & & / bid document 1 / 18
Tender For job work for replacement of old copper cable by 50sq.mm multistrand new copper cable of 02 nos 220v dc fcbc charger at 400kv s/s dn., csptcl dhamtari (kurud).