Get complete information related to latest Power Supply Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Supply Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Supply Work Tenders.
Tender For corrigendum : repair-maint of building services connection improvement of earthing and connected work at binnaguri mil stn under ge (north) binnaguri
Tender For corrigendum : repair / replacement and maint of lt external electric supplyworks and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For corrigendum : repair/maintenance of dg sets, amf panels , control panels, voltage stabilizers, isolation transformers, air compressors ,earthing/lightning protection and connected work of different capacity in east wing and singhpur in tech area af station gwalior
Tender For corrigendum : repair and replacement of unsv lightening conductor earthing test point at esh shed other storage shed in a a banar under ge banar
Tender For corrigendum : comprehensive repair and maintenance of lightning protection of building earthing and wiring and other connected items under ge babina
Tender For corrigendum : repair and maint of earthing solar heating appliances lightning protection and electric energy meters of various central institute and bldgs under ge south udhampur
Tender For corrigendum : repair/maintenance of main distribution boards, service connections, submain wiring, building security lights, building earthing and connected works under ge (east) mathura
Tender For corrigendum : ca no. ge af no.1 / gur-47 / 2026-27 repair/ maint of lightening protection system, copper strip earthing earthing, fire fightening and repair maint of meter, ups and fire alarm system along with miscellaneous repair and maint at 13 brd 16 brd
Tender For corrigendum : repair replacement of lt ug cables, poles, acb, voltage stabilizer, lt panel, earthing and connected accessories at mil stn gaya