Web Analytics Made Easy - StatCounter

Power Transformer Repair Tenders

Get complete information related to latest Power Transformer Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Transformer Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Transformer Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43275810 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For upg of variac for rdr tc reporter

CTN :43275812 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For supply of proj for upg of variac for rdr flycatcher

Co-operative

CTN :43246302 Due date: 29 Dec, 202529 Dec, 2025 17.1 Thousand
Tender For supply of electronics rehyostate 40a,variac and driving link,samarpan,prism10k:d984739 - 3204110, 24.000, driving link, samarpan, prism10k: d984739

Co-operative

CTN :43246298 Due date: 26 Dec, 202526 Dec, 2025 89.6 Thousand
Tender For supply of packing machine samarpan spares - 3072501, 100.000, bush,samarpan,prism10k:m400488, 3201893, 5.000, ver. sealing card 40a variac,samarpan, 3001597, 100.000, driven longpin,samarpan,prism10k:m610443, 3201904, 50.000, compression spring,prism10k:d984436

CTN :43180265 Due date: 24 Dec, 202524 Dec, 2025 NA
Tender For supply of work shop lab equipment and machineries for department of food technology and dairy technology - purchase of basic engineering workshop (equipment), centre lathe machinelight duty, 1.5 hp, bed length 4.5 ft, swing 300 mm, shaper machinestroke length 300 mm, motor 1 hp, adjustable feed, drilling machine (bench type & floor type)0 13 mm capacity, 0.5 hp, 230 vnterface capacity up to 8/10 tb12 vdc power supply, pillar drilling machine20 mm capacity, 1 hp, arc welding transformer set (portable)300 a, 230/415 v with accessories , bench grinder200 mm double-ended, 1 hp, power hacksaw machine200 300 mm stroke, motorized, casting & moulding setupsand muller, moulding box, patterns, tools, vernier caliper0 150 mm, least count 0.02 mm, micrometer (outside) - 0 25 mm, least count 0.01 mm, steel rule - 300 mm, stainless steel, try square - 150 mm, hammer set - ball peen, cross peen, sledge, files - flat, round, half-round, triangular, 250 mm, hacksaw frame with blades adjustable, 300 mm, 24 tpi, chisels - flat, round nose, cross-cut, 200 300 mm, taps and dies set metric, m6 m20, bench vice 100 mm, swivel base, c-clamps - 100 mm opening, spanners & wrenches set 6 32 mm, calipers (inside & outside)150 mm, scriber & surface plate 300 300 mm cast iron plate, angle plate & v-block hardened steel, hand drilling machine - (0 10 mm), wood saw (hand & tenon saw)hand type, anvil & swage block 15 kg, mild steel - 1 no each, carpentry tools set - jack plane, chisel set, marking gauge, mallet, sheet metal tools - snips, stakes, groover, seaming tool, sheet metal folding/bending machine (hand/bench)capacity 1.0 2.0 mm ms sheet , vernier height gauge - 0 300 mm, least count 0.02 mm, slip gauge (gauge block) setasme/bs standard, 1.000 100 mm set, tool room workbench with vice (heavy duty)4 benches, marking / surface plate accessoriesscriber, surface clamp, angle plate, dial indicator / test indicator 0 10 mm, 0.01 mm resolution, bevel protractor - 0 360 , least count 5 or 1 , punches & drifts set - 2 12 mm, center punch, prick punch steel, 4 10 mm, resistive load bank - variable 0 5 kw, suitable for 1 and 3 operation, auto transformer (variac) - 0 270v (1 ), 0 470v (3 ), 10a, digital multimeter auto-range, true rms, 0 600v, 10a, rheostat(wire wound)200 /2a ,50 /10a ,100 /5a (each 2 sets), cro / digital oscilloscope dual channel, 20 mhz, function generator - 1hz 100 khz, sine/square/triangle, digital tachometer - non-contact, 0 10,000 rpm, wattmeter lpf & upf - 0-600v ,0-20a, ammeter (ac/dc) - 0-5a,0-30a (each 5 nos.), stop watch - digital,0.01 s resolution, inductors/coils - 0.1h to 1h,10 a rating, dc power supply rectifier, power factor meter - 0 270v (1 ), 0 470v (3 ), 5a, industrial protection devices board mcbs, elcb, mccb, fuses, relays - board, industrial electrification trainer- 3-phase wiring, contactors, relays, indicators, ac power distribution panel, dc power distribution panel

Central Government / Public Sector

CTN :43197826 Due date: 07 Jan, 202607 Jan, 2026 NA
Tender For supply & installation of abel flash point apparatus for determination of low flash point of petroleum products, solvent, oil and mixtures with copper water jacket digital indicator, motorized stirrer, electrically heated, gas pilot flame system along with gas cylinder & copper coil voltage variac as per ip-33, ip-170, is 1448/part 20 : 2024 (iso:13736/2021) or latest. apparatus should have the provision to insert thermometer to read the temperature and a calibrated thermometer should be provided with the apparatus. (technical & standard accessories as per attached annexure- a). make: power and electricals co-kolkata or equivalent.

Central Government / Public Sector

CTN :43197524 Due date: 01 Jan, 202601 Jan, 2026 NA
Tender For supply of pensky marten flash point apparatus as per ip -34 , astm d-93 & is 1448(p-21). electrically heated model with digital temperature control. motorized geared stirrer for stirring the cup sample. sample cup with flame device and shutter arrangement. reducing socket with cock for gas jet test flame. also fitted with voltage variac and rpm counter. make: power and electrical/pic or similar

CTN :43148374 Due date: 26 Dec, 202526 Dec, 2025 10.72 Lacs
Tender For supply of dc ammeter , ac ammeter , dc voltmeter , ac voltmeter , wattmeter , power factor meter , rheostat , rheostat double tube , wire striper , screw driver , plier , nut driver , pop spaner , line tester five hundred volts , cable cutter , pvc batten , pvc conduit , pvc casing and caping batten , hydraulic crimping tool , hand crimping tool , mcb single pole , dpmcb , module box for fitting of switches sockets etc , switches , fan regulator , socket , angular holders , main switch dpmcb , changeover switch , elcb , rccb , two way switch for module fitting , ordinary electric bell , relay for bell circuits , wooden board , acsr wire dog conductor for making joints practice , g i pipe earthing with all accessories , g i plate earthing with all accessories , electric iron , water heater , heat convector , desert cooler , room heater , mixer , blender , drilling machine , pvc bends , pvc junction boxes , clamp on meter , soldering iron station , lamp , variac , dc regulated power supply , kcl kit , kvl kit , galvanometer , conversion of galvanometer into ammeter and voltmeter kit , wheatstone bridge , capacitor , lead acid battery , lithium ion battery , battery management system and controller for electric scooty , induction coil air core iron core , rl rc and rlc kit for active reactive and apparent power , load bank , current transformer , potential transformer , earth tester , megger insulation tester , energy meter , inductive load bank , capacitive load bank , patch cords , cro probes

Central Government/Public Sector

CTN :43137919 Due date: 12 Jan, 202612 Jan, 2026 NA
Tender For supply of auto transformer (variac) - 4a & 2a

Central Government/Public Sector

CTN :42956361 Due date: 26 Dec, 202526 Dec, 2025 61.87 Lacs
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi
 Loading, Please wait...

Connect us via What's Up