Tender For auction sale of 3.15 mva bgp failed ptr scrap,10 kva copper wound transformer (without oil)-08 nos,11, 33 kv ct/pt units etc,iron steel scrap (field return), barberd wire scrap,fiber scrap, scrape of energy meter mechanical/ electronic/static etc,transformer leminations used,copper winding wire/coils of transformer and mo,tank empty old of transformers /ocb/vcb/equipments,battery scrap (lot ctrl)
Tender For supply of memu item :- oil flow sensor part no. n0284517 suitable for 3 phase ac memu siemen's make transformers model no. gp 194, type- efat 6144, icf medha. [ warranty period: 30 months after thedate of delivery ] ]
Tender For supply of memu item : oil flow sensor part no. n0284517 suitable for 3 phase ac memu siemen's make transformers model no. gp 194, type- efat 6144, icf medha. [ warranty period: 30 months after the date of delivery ] ]
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : repair / maint of 11 kv network, distribution and powertransformers incl dehydration/filtration of oil and other connected allied works in sector c and d army area jodhpur under ge (army) no. 01
Tender For corrigendum : supply of 630 kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor transformer , 1000 kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor transformer , 2000 kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor transformer , 2500 kva, 11kv/0.433kv, 3 phase, 2 winding, outdoor transformer , 2500 kva, 11kv/3.45kv, 3 phase, 2 winding, outdoor transformer , type test for 630 kva, 11/0.433kv transformers for sipat project , type test for 1000 kva, 11/0.433kv transformers for koderma project , type test for 2000 kva, 11/0.433kv transformers for koderma project , type test for 2000 kva, 11/0.433kv transformers for sipat project , type test for 2500 kva, 11/0.433kv transformers for koderma project , type test for 2500 kva, 11/0.433kv transformers for sipat project , type test for 2500 kva, 11/3.45kv transformers for koderma project , extra oil (5% ) for pem scope transformers for koderma , extra oil (5% ) for pem scope transformers for sipat , extra oil (5% ) for tbg scope transformers (1000 kva, 11kv/0.433kv, 3 phase) 2 nos. , oil filled service transformer - mandatory spares for koderma project
Tender For tender for painting of 220/132kv, single phase 150 mva power trf bank (b phase and spare trf) and identifying and sealing oil leakage points of both transformers installed at 220/132/33/11kv sub-station, hpsebl, jassure under es division, jassure
Tender For corrigendum : contract for hiring the services of oil filtration machine, transformer oil storage tank, air dryer generator and transformer testing equipments for powertransformers and reactors of unit-1,2,3 and 4 (4x250 mw) stage-i, phase-i and ii ctpp, chhabra.