Get complete information related to latest Pre Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pre Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pre Filter Tenders.
Tender For supply of -replacement (installation & repair)of sediment filter for pre-filter-03 nos, sediment filter for primary plant -03 nos.,carbon filter for primary plant 02 nos. ,di cartridge for primary plant -01 nos., ro membrane (8") for primary plant -02nos,frt(550ml) for primary plant 02 nos, solenoid valve for primary plant -01 nos ,ro membrane fore kent plant 01 nos ,frt (550ml) for kent plant -01 nos. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: prefilter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: prefilter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For supply of air purifier, rated voltage: 220-240v, rated frequency: 50/60 hz, rated power: 85w, noise( high speed): 59db/a, noise (low speed) : 38. odb/a, anion concentration: 10 million/cm3, amount particute cleaned air ( cadr)2: 101.6m3/h, applicable area 2: 1008 square feet/ 93 square meters, suggested period to replace filters 1: prefilter and humidifier filter life up to 2 years compound filter 1: anti-bacterial filters, silver ion and h13 filters life upto 9000 hrs or 1 year, compound filter 2: cold catalyst filter and activated carbon filters life upto 9000 hrs or 1 year, net weight: 11.3 kg, product measurement : l400xw230xh640mm, components: prefilter and humidifier, compound filter1: anti-bacterial filters, silver ion and h13 filters, compound filter 2: cold catalyst filter and activated carbon filters, fan speed :1-8, alexa-enabled, air quality display: yes, filter rest indicator: yes, 4color air quality indicator : yes, wi-fi & smart app control : yes, filters life : 9000hrs upto 1 years, uv : led, child lock button : yes, sleep mode : with 1-12 hr automatic shut- off time, warranty : 2 years onsite. [ warranty period: 24 months after the date of delivery ] ]
Tender For repair/supply new spare bod - envtek make - 115275, 1.000, repair/supply new spare bod make - envtek (double decker)make- novamodel- dsd/vcc/znc/03repair/replace below mention spare1)compressor 1pc2)fan 1pc3)ssr 1pc4)filter 1pc5) gas 2pc7)compressor 1 year warranty., 101237, 1.000
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : supply of quench cum venturi cum packed bed column cum bop as per annexure_3_ price bid format cl.1.1a_1.1b_1.1c , gas to gas heat exchanger as per annexure_3_ price bid format cl.1.1 d , sintered metallic filter system as per annexure_3_ price bid format cl.1.1 e , mercury guard bed with catalyst as per annexure_3_ price bid format cl.1.1 f , special tools _tackles as per annexure_3_ price bid format cl.1.2 , consumables, lubricants, commissioning spares as per annexure_3_ price bid format cl.1.3 , spares, special maintenance tools as per annexure_3_ price bid format cl.1.4 , mandatory spares as per annexure_3_ price bid format cl.1.5 , supervision services _per diem rates per service engineer _as per annexure_3_ price bid format cl.2.1 , supervision services _travel expenses from vendor works to project site and back _as per annexure_3_ price bid format cl.2.2