Get complete information related to latest Pressure Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pressure Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pressure Fan Tenders.
Tender For provision of inverter with battery and wiring 04 no of ceiling fan 02 nos wall fan led batten lights and repair/replacement of electric points (tourist office samba).
Tender For corrigendum : repair maint ceiling fan exhaust fan including repair rewiring of cooling and heating devices and repair maint rewiring of married accommodation of officers quarters under ge danapur cantt
Tender For corrigendum : repair to unserviceable electrical fittings fixtures to maintenance ceiling exhaust fan and geysers including day to day services in md and otm accn at allenby lines manoj pandey enclave and adjoining area under ge (s) ambala cantt
Tender For repair maint of building secutiry lights bulk head light fittings, ceiling fan exhaust fan wall marked fan, point wiring, sub main wiring, mccb, mcb, db at various otm accn/ md accn at burki and tpt line and replastering and painting of security wall,
Tender For corrigendum : repair replacement of internal wiring point wiring and sub main wiring including connected items at zone b otm and md accn at ins rajali under ge m arakkonam - taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed., material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- make of cable : plaza/polycab/finolex/ havells, one light/ fan/ exhaust fan/ buzzer point controlled by one switch., one 3 pin socket outlet 6 amps, independent board with cables 1.5 sqmm size., one 3 pin socket outlet 6 amps,same board with cables 1.5 sqmm size., one light point controlled by two 2- way switches, with cable 1.5 sqmm size., all as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size.make :- polycab/finolex/plaza/havells, material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor drawn into pvc conduit and casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- make for pvc casing & caping: sudhakar / avon plast /plaza , make for copper cable: finolex/polycab / plaza., one light point controlled by one switch., one 3 pin socket outlet 6 amps, indipendent board with cables 1.5 sqmm size., all as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size. make :- polycab/finolex/plaza, m&l for sub main wiring for phase and neutral with pvc frls insulated unsheathed multi stranded along with earth wire frls pvc insulted copper conductor, single core cable in and including surface/concealed /pvc conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. make for copper cables: finolex/polycab / plaza/ havells. make of pvc conduit: sudhakar/finolex/avon plast., 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire, 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire, 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire, 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire, 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire, 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire, taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed., supply and fixing in repair of gi metal flush box suitable for mounting moduler plate of following modules:-, 1 or 2 module, 3 module, 4 module, 6 module, 8 module, 12 module, supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for followin
Tender For corrigendum : repair repl of intl elct wks incl rewdg of clg fan exh fan w/m fan lt ftgs sub main wirg geyser and oth allied wks incl ot lts at ph i of mh kke repair maint of diesel generator set amf pnls synch pnl and allied wks at mh kke range hls area hq 41 arty div and aund - repair replacement of internal electric works including rewinding of ceiling fan, exhaust fan, wall mounted fan, light fittings, sub main wiring, geyser and other allied works including ot lights at phase-1 of mh khadki including 41 arty div and repair and maintenance of dg set, amf panels, synchronising panel and allied works at mh khadki, range hills area, hq 41 arty div and aundh military complex under ge (mh & rh) khadki
Tender For supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For supply of breakdown call, inspection, fault finding diesel generator set site distance up to 50 km,breakdown call, inspection, fault finding diesel generator set above 50 up to 100 km,breakdown call, inspection, fault finding diesel generator set above 100 k up to 150 km,preventive maintenance diesel generator set 15 to 20 kva,preventive maintenance diesel generator set 22 to 25 kva,preventive maintenance diesel generator set 30 to 45 kva,preventive maintenance diesel generator set 63 kva,replace banjo bolt with copper sealing washers,replace hand primer with valve kit,provide fix flexible trapezoidal v belt,replace fuel pipe tank to filter up to 2m,replace fuel pipe filter to pump,replace overflow return pipe nozzle to tank,replace battery terminal cables 18 sq mm 1 mtr length,replace blower fan bearings air cooled dg,replace water pump assembly complete,supply fix 12v dc stop solenoid,top up lubricating oil as recommended,replace heavy duty air filter 15 to 30 kva,replace heavy duty air filter 32.5 to 40 kva,replace heavy duty air filter 50 to 63 kva,repair self starter motor up to 63 kva,replace self starter pin