Get complete information related to latest Pressure Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pressure Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pressure Switch Tenders.
Tender For supply and installation of aerosol based fire detection and suppression system cartridges (100gm+100gm), total 02 pieces as per detailed technical requirement specified in the annexure - g 1 of rdso specification no. rdso/pe/spec/ac/0192-2018 (rev-1) and rdso approved make only. the mounting arrangement shall be suitable for installation in switch board cabinet panel of lhb ac coaches. all necessary modification & accessories required for installation of this item shall be within scope of supplier.as per rdso spec. makes are firepro, stat-x, pyrogen technology and with prior approval of rdso. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for provision of ss plate drain tray over switch board cabinet (sbc) of lhb coaches to prevent entry of rainwater into electrical system over ddn (72 nos.), ynrk (15 nos.) & be (30 nos.) coaching depots of moradabad division.
Tender For corrigendum : supply of rotary switch 300 amp, 250 volts dc, 4 position, 2 pole, 3 way with off suitable for universal mounting, with capstan handle, rotary switch in open execution, sequence pos1. (12 o' clock) - off, pos 2. (3 o' clock) -1-a, pos 3. (6 o' clock) -1-b, pos 4. (9 o' clock) -1-a, 1-b switch, 03 nos of seperating plate, confirming to is 13947 pt iii, category - a similar to cat no.- c3013 yu22 of kaycee as per edts-006, make - kaycee, salzer, l&t only. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of bis 110 changeover switch to medha part no. sp648v25021. make- medha [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, fitment, installation, commissioning and testing of electrical variable voltage variable frequency ac drive rating-15kw/11kw, 3-phase 380-480 vac 50/60 hz, dc power supply: 510-680 vdc (cimr- ad4a0031fma).nominal input current (nd):24 amp. nominal input current (hd): 31 amp. output power rating (nd):15kw.output power rating (hd):11kw.frequency control range: 0-400hz.motor power-15kw/11kw.emc filter class c2 integrated. braking of standstill by dc injection. salient features: operation mode selection ,dc injection braking and short circuit braking ,speed search ,delay timer, pid control ,dwellfunction ,energy saving, acceleration and deceleration times ,slip compensation, torque compensation ,carrier frequency, frequency upper/lower limit torque control ,jump frequency. main control functions: torque control , drop control speed/torque control switch, feed forward control, zero servo control, momentary power,loss ride- thru and speed search, over torque detection, torque limit. speed control range : v/f control 1:40, open loop vector control 1:200, open loop vector control for pm 1:20, closed loop vector control for pm 1:1500, v/f control with pg 1:40 ,closed loop vector control 1:1500, advanced open loop vector control for pm 1:100. output overload tolerance: nd rating: 120% of rated output current for 60s, hd rating: 150% of rated output current for 60 s (derating may be required for repetitive loads).protection design: ip00 open-chassis, ul type 1 enclosure. ambient temperature (open-chassis): 10 to +50 degree celsius. standard compliance: ul508c iec/en61800 iec/en61800-5-1 ,two safe disable inputs and 1edm output according to iso/en13849-1 cat.3 pld iec/en61508 sil2. make: yaskawa /schnieder /abb/siemens/mitshubishi/angel or similar. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For insulation monitoring relay,415 v ,3 phase, neutral isolated, voltagerange 0-500 v ac, insulation measuring range-10 k ohm to 150 k ohm, control supply 24-240 v ac/dc, place of installation - s1a7, used for insulation control 415 v of lhb type ac coaches, confirming to rdso spec. no.rdso/pe/spec/ac-0184-2015 (rev.1), suitable for lhb type ac coaches switch board cabinet (s1a7),accepted make as per s. no.68 of the common bom list issued vide rdso letter no. el/7.1.108/mssbc dated 17.09.2021 or any other rdso approved make. [ warranty period: 30 months after the date of delivery ] ]
Tender For timer switch analog type with manual setting suitable to operate 230 volt, 50 hz, ac supply contact rating 16 amps with battery back up of minimum 48 hours fully charged condition [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of switch plate assembly complete with polycarbonate cover frame and powder coated steel plate with 2 nos. on-off switches and 2 nos. 3-pin socket 6a, 250v ac with 02 nos., 2 amp. glass fuse of m/s. ferraz shawmut/cooper bussman or equivalent (with fuse holders) as per rcf specification no. edml-064, rev-b, amendment-4, table-8 and drawing. no. lw74202 alt-f, item no. 17, or latest. [ warranty period: 30 months after the date of delivery ] ]