Get complete information related to latest Pressure Transducer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pressure Transducer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pressure Transducer Tenders.
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressuretransducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For supply, installation, testing and commissioning of radar type pressuretransducer of 2 nos. pump sets at jaitpur village bps under badarpur constituency ac-53. - supply of digital pressuretransducer, range 0-16 kg/cm2, connection 1 4 bsp (m), body ip 65, accuracy +/- 0.5%, output 4-20 ma, input 24v dc, operating temperature -20deg. to 80 deg. c, deviation 0.3%, protection cover for digital pressuretransducer. supply of 7 segment indicator with 4-20 ma input, 4 digit indicator, character size 4 inch with provision of decimal, provision for wall mounting / hanging, ms body with powder coating. supply of 2 core x 1.5 sq mm cable approx 25 mtr. installation, testing and commissioning charges including all the electrical work to be done installation of switch, socket in the gang box (waterproof pvc), pvc pipe for all the wiring and the interconnections between the transducer and indicator. make: skope/ vega/seimens/eip/djb approved
Tender For supply of advance integrated video urodynamic workstation -urodynamic equipment with buy back of the existing urodynamic equipment installed in the user department , detachable side rail , fixed patient armrest , plastic funnel drainage detachable arm rest , foot rests , armrest holder , hand control , should be supplied with 4 channel anorectal manometry hardware and software with catheters for doing anorectal manometry , 2 lumen catheter 8fr for cystometry , 2 lumen catheter 6fr for cystometry , 2 lumen 5fr pigtail catheter for cystometry , rectal ballon catheter should be between 10 to12 fr , pump tube , surface electrodes for emg , disposable domes , connection tubing , upp catheter 3 lumen , arm catheter 4 channel 1cm long with ballon , transparent security cover for uroflow transducer , near infrared specroscopy nirs for dynamic topography of pelvic muscle to understand the hydrogenation and dehydrogenation of pelvic bladder muscle to correlate with urodynamic studies , leak point detector module to detect even a small drop of leakage which do not come into uroflow , height adjustable uroflow stand with removable funnel , height adjustable folding micturation chair with detachable arm for urodynamic studies with removable funnel , anal probe for biofeedback , digital video urodynamic software and hardware for doing video urodynamic studies , emg biofeedback software for complete pelvic floor assessment and training with international standard games with anal probe and vaginal probe for biofeedback , urethra perfusion line , urodynamic pressure kit , vaginal probe for biofeedback , wired rf based uroflow transducer , wireless emg with visual and sound , wireless rf based uroflow transducer , computer run on latest windows software integrated key board twenty to twenty four inches color led monitor along with optical mouse speakers and color laser printer , video urodynamic chair , weight based uroflow transducers one wired and one wireless , protecting cover for flow transducer , uroflow stand , 2 litre beaker , reusable pressuretransducers. , collection jug 2ltr , infusion sets , protective plastic cover for flow transducer , 500 gm calibration weight , removal funnel , ultrasound gel , thermal printer paper roll , color printer cartridge , should be supplied with fnirs functional near infrared spectroscopy for bladder muscle , thyroid shield , lead apron , stand , should be supplied with 3d bladder scanner for pvr measurement for complete urodynamic studies , cmc for first year , cmc for second year , cmc for third year , cmc for fourth year , cmc for fifth year , cmc for 6th year , cmc for 7thyear , cmc 8th year