Web Analytics Made Easy - StatCounter

Printed Circuit Board Tenders

Get complete information related to latest Printed Circuit Board Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Printed Circuit Board Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Printed Circuit Board Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45726066 Due date: 31 Jul, 202631 Jul, 2026 25.00 Lacs
Tender For inviting rates of electrical and repair material for financial year 2026-27 at nagar palika parishad tikamgarh - inviting rates of electrical and repair material for financial year 2026-27, approved and suitable make led driver for led street lights 50watt, color temp 3000-6500k, approved and suitable make led driver for led street lights 60watt, color temp 3000-6500k, approved and suitable make led driver for led street lights 90watt, color temp 3000-6500k, approved and suitable make led driver for led street lights 120watt, color temp 3000-6500k, approved and suitable make led driver for led street lights 150watt, color temp 3000-6500k, approved and suitable make led driver for led flood lights 150watt, color temp 3000-6500k, approved and suitable make led driver for led flood lights 200watt, color temp 3000-6500k, 100w led metal core printed circuit board (mcpcb) commonly used for high-power floodlights or street lights jps 3105 90w 08 5810c 2100w ytba0106 170513, led metal core printed circuit board (mcpcb) used for low power street lights marked ccc- 14679 160x100 mm- 2835-100sc, ip66, fluorescent tube rod 36/40 watts isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, fluorescent electronic ballast chock 36/40 watts isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, fluorescent tube rod side holder isi marked of approved make as required as per specification, anchor, reputed make equivalent`, ignitor 70/125/150/250/400 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour lamp 150 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour chock 150 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapoursodium vapour porcelain holder 150 watt e40 isi marked of approved make as required as per specification, anchor, finolex reputed make equivalent`, sodium vapour lamp 250 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour chock 250 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour sodium vapour porcelain holder 250 watt e40 isi marked of approved make as required as per specification, anchor, finolex reputed make equivalent`, sodium vapour lamp 400 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour chock 400 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, sodium vapour sodium vapour porcelain holder 400 watt e40 isi marked of approved make as required as per specification, anchor, finolex reputed make equivalent`, led bulb 9 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, led bulb 18 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, led bulb 23 watt isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, led bulb holder for 9w/18w/23w isi marked of approved make as required as per specification, havells bajaj, philips, crompton, surya, equivalent, 18w led tube rod integral tube fitting complete as required marked reputed make havels, philips . rr, c&s, surya etc equivalent, tape roll steel grip roll isi marked, universal clamp with bracket complete for tube light fixture / any street light universal iron clamp 300mm pipe length 25.4 mm dia. with bracked nut bolts complete as required as per specification, universal clamp with bracket complete for tube l

Central Government And Public Sector

CTN :45712357 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For providing of artificial intelligence, machine learning, and deep learning as a service - development; printed circuit board; defence; document attached; as per service provider's solutions; as per service provider's solution; as per service provider's solution; d..

CTN :45714443 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of printed circuit board (q3)

CTN :45704594 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For tender for charges for visit of oem service engineer , printed circuit board, model dci-tx , signal and power barrier, cms, korosi

CTN :45710396 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For renovation and repair work of pcb, ppms & cadsl lab's in annex building, electrical engineering department.

CTN :45695641 Due date: 15 Jul, 202615 Jul, 2026 43.99 Lacs
Tender For renovation and repair work of pcb, ppms and cadsl labs in annex building, electrical engineering department.

CTN :45672519 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For tender for replacement of pcb /repair of double glass door, vertical standing medical refrigerator
 Loading, Please wait...

Connect us via What's Up