Get complete information related to latest Protective Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Protective Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Protective Relay Tenders.
Tender For fully automatic star delta starter control panel suitable for 10hp submersible pumpset.operate on three phase 415v,50hz ac supply conforming to is/iec 60947-4-1, with thermal bimetalic relay for protection against overload,single phasing (current sensing ),phase unbalance,phase reversal,having over load relay range :13.2a-20a,contactor current rating-20a,over all dimension :408mm*147 mm*400mm l*w*h.thickness of ms sheet -2mm, with analog ammeter & voltmeter ,starting capacitor capacity(mfd)=80-120mfd, running ca pacitor capacity (mfd)= 34mfd,ip-54 ,including on&off indication lamp.the firm has to submit the model number in biddng.only oem / oem authorised dealer has to participate with relevant documents. make: larsen&toubro,havells,bch,siemens and crompton [ warranty peri od: 12 months after the date of delivery ]
Tender For corrigendum : supply of phoneix contact make electrical spares - switched-mode power supply, 1-phase, with push-in clip, control in primary circuit, input ac 100-240v, output dc 24v-5a as per annexure-1a , switched-mode power supply, 1-phase, with push-in clip, control in primary circuit, input ac 100-240v, output dc 24v-10a as per annexure-1a , switched-mode power supply, 3-phase, control in primary circuit, input 3ac 320-575v, output dc 24v-40a as per annexure-1a , insertable miniature relay dc 60v, 1co, load - 230v-6a as per annexure-1a , insertable miniature relay dc 110v, 2co, load - 250v-8a as per annexure-1a , modular unit for relay mounting, 1co, power supply ac-dc 230v, width 6.2mm, rcz-filter in control circuit side as per annexure-1a , modular unit for relay mounting, 2co, power supply ac-dc 230v, width 14mm, rcz-filter in control circuit side as per annexure-1a , universal terminal block, gray, 32a, 1000v, standart size 2.5, width 5.2mm, doubleside screw connection as per annexure-1a , pe-terminal yellow-green, 32a, 1000v, standart size 2.5, width 5.2mm, double-side screw connection as per annexure-1a , universal terminal block, gray, 41a, 1000v, standart size 4, width 6.2mm, double-side screw connection as per annexure-1a , divider plate, length 42.5mm, width 2.5 mm, height 30.5 mm, colour gray as per annexure-1a , fuse terminal, black, 6.3a, 24v, standart size 4, width 6.2 mm, fuse 5x20, indicator 24v ac-dc as per annexure-1a , modular relay insulation, ac 230v, 50-60 hz 2co, load - 250v-8a, relay, base, led, clamp, plate as per annexure-1a , power socket, 3-pole l-n-pe, rated current - 16a, 230 v ac as per annexure-1a , spd, for 4-wire power supply systems as per annexure-1a , switched-mode power supply, 3- phase, control in primary circuit, input 3ac 320-575v, output dc 24v-5a as per annexure-1a , modular relay insulation, ac 230v, 50-60 hz 4co, load - 250v-5a, relay, base, led, clamp, plate as per annexure-1a , terminal with overvoltage protection, 10a, 24v, width 6.2 mm, black, double-side screw connection as per annexure-1a , switched-mode power supply, 1-phase, with pushin clip, control in primary circuit, input ac 100-240v, output dc 24v-3a as per annexure-1a
Tender For supplying and fixing of spare part for maintenance of different ht starters (6.6 kv) operating and comprehensive maintenance of different electrical installed at hocp for period of 365 days. - item description/ heading, vacuum contactor assembly ,motor protection relay , off load isolator shall be supplied departmentally, indicating lamp, push buttons, isolator moving contact, isolator fixed contact, isolator operating shaft, coil for vacuum contractor 110v dc, auxiliary contactor 2no+2nc, drive insulator for vc, vacuum interrupter for vc, trip spring for vc, copper terminal, resistance for vc, bottom support insulator, ht hrc fuse for pt, ammeter /voltmeter selector switch, recitifier capacitor 63a, idmt 2 o/c & 1e/f relay ,aux .volt 110v ac/dc ,5a, ammeter, voltmeter, limit switch, cable gland cone (brass)-wipen type, fuse base & carrier up to 20a, pvc insulated service wire 1 core, 2.5sqmm, earth leakage relay, copper lug socket 95 sqmm, copper lug socket 120 sqmm, day to day maintenace of ht starters, total impact of gst plus labour cess [@ 1 % (bocw cess to be deducted from the ra bill as per the value of the work progress)] for the purpose of ctc
Tender For spares of boiler i.e. micro limit switch, solenoid for oil gun etc. - supply of spares for boiler i.e. micro limit switch, solenoid for oil gun etc. as per nit annexure-i, micro limit switch contact type spdt, roller lever, screw terminal , z15gw22-b 15a 125, 250 or 480 v ac, magnetic limit switch 2 wire voltage rating dc/ac 5-240 v , 100ma , 10 w , 2meters cable, solenoid for ignitor : single coil valve 5/2 way , 5 port 2 position , 4v 210-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., solenoid for oil gun : double coil valve 5/2 way , 5 port 2 position , 4v 220-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., solenoid for oil /purging/ atomising valve : single coil valve 5/2 way , 5 port 2 position , 4v 310-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., air filter regulater unit media : air , adjustment : knob type / nut type, input /output port size : 1/4 npt (f) , pressure range : 0-10 kg/cm2, manual drain with pressure gauge (0-8) kg/cm2, metal bowl seal : nbr, filter rating : 5um, filter material : sintered bronze, power contactor , coil rating 230v ac, pole : 3 , make : schneider electric, model lc1d09 , current rating : 9a, voltage rating : 415v, feedback positioner ffnb-5420 make : moniteur watchman, power relay make : idec model :ru4s-a220, voltage rating 220/240 ac, current rating 6a, contact arrangement 4pdt, contact 6a, 30 vdc, ru series 14 pin, power relay make : idec model :ru2s-a220, voltage rating 220/240 ac, current rating 6a, 8 pin, position transmitter 2 wire contactless , input angle range : 0 to 90 degree , output 4-20ma dc, operating power supply 10 v dc to 60 v dc , ingress protection ip67, operating temperature 0 to 80 degree, i/p converter input 4-20 ma, output : 0.2 to 1 bar , supply pressure 1.4+/-0.1 bar, air capacity > 5kg/h, pneumatic connection 1/8 npt for air supply and output. electrical connection: 2 pole screw terminal for 2.5 mm2 model : teip/v18311h-1121101. make abb, limit switch return v04, part id v04-11-4 make : clyde bergemann, limit switchmake: clyde bergemann. z4v10h-336-11z-1593-6 , part id : e0000093, continuous rating heavy duty industrial panel fan with finger guard accessory , operating rating 220vac , fan diameter 4" make : nisiki/ rexnord /delta
Tender For supply of heavy duty industrial type 40 hp fully automatic star delta starter, 415 volt ac, 50 hz, ove rload relay range 24.4 amp. to 39 amp. with in built single phase preventer, motor on indication, trip indi cation, healthy phase(r,y,b) indication, voltmeter, ammeter, heavy duty contactors, coil voltage 415 vac, protection against phase loss, phase reversal, phase unbalance, under voltage & over voltage confo rming to is/iec 60947-4-1 equivalent to bch make cat no.nasact1ledm [ warranty period: 30 months a fter the date of delivery ]
Tender For providing of operation and maintenance of electrical systems/electrical installations - service item no 1- manpower,operation and maintenance of electrical systems/electrical installations - service item no 2- serial lighting to terminal building & atc block,operation and maintenance of electrical systems/electrical installations - service item no 3 - testing and calibration of protectiverelays,operation and maintenance of electrical systems/electrical installations - service item no 4 - servicing of lt air circuit breaker,operation and maintenance of electrical systems/electrical installations - service item no 5 - servicing of ht vaccume circuit breaker,operation and maintenance of electrical systems/electrical installations - service item no 6- painting of transformer housing box,operation and maintenance of electrical systems/electrical installations - service item no 7 - rewinding of the 7 to 10 hp submersible motor pump sets,operation and maintenance of electrical systems/electrical installations - service item no