Web Analytics Made Easy - StatCounter

Psc Pipeline Repair Tenders

Get complete information related to latest Psc Pipeline Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Psc Pipeline Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Psc Pipeline Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39855018 Due date: 25 Apr, 202525 Apr, 2025 27.48 Lacs
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as

Central Government/Public Sector

CTN :40007719 Due date: 18 Apr, 202518 Apr, 2025 NA
Tender For three year annual maintenance contract of gas distribution system with spares and consumables at ntpc khargone

CTN :40000514 Due date: 01 May, 202501 May, 2025 NA
Tender For tender for hiring of light commercial vehicles for city gas distribution project in kamrup and kamrup metropolitan ga and cachar karimganj hailakandi ga of pbgpl on 3 years annual rate contract

CTN :39977274 Due date: 24 Apr, 202524 Apr, 2025 NA
Tender For tender for gas cylinder distribution at lohaghat gas service attach market and city

CTN :39977276 Due date: 24 Apr, 202524 Apr, 2025 8.00 Lacs
Tender For tender for gas cylinder distribution at gangolihaat gas service attach market and city

CTN :39977279 Due date: 24 Apr, 202524 Apr, 2025 5.00 Lacs
Tender For tender for gas cylinder distribution at kanda gas service attach market and city

CTN :39977280 Due date: 24 Apr, 202524 Apr, 2025 5.00 Lacs
Tender For tender for gas cylinder distribution at devidhura gas service attach market and city

CTN :39977282 Due date: 24 Apr, 202524 Apr, 2025 10.00 Lacs
Tender For tender for gas cylinder distribution at berinag gas service attach market and city

CTN :39977283 Due date: 24 Apr, 202524 Apr, 2025 8.00 Lacs
Tender For tender for gas cylinder distribution at thal gas service attach market and city

CTN :39977284 Due date: 24 Apr, 202524 Apr, 2025 8.00 Lacs
Tender For tender for gas cylinder distribution at betalghat gas service attach market and city
 Loading, Please wait...

Connect us via What's Up