Get complete information related to latest Psc System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Psc System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Psc System Tenders.
Tender For augmentation & provisioning of ipis (train display boards, passenger amenities equipment) along with gps clocks at janghai jn. railway station of lucknow division.
Tender For kerala water authority-funds-water quality testing- supply of lab equipments-at konni thazham wtp - procurement of equipments, od121756/2025-2026:supply and installation of microcontroller based ph meter with 3 point calibrationi) ph:-range : 0.00 to 14.00 ph or better resolution: 0.01or better accuracy:+0.02 or -0.02 ph or better calibration points: 3 points minimumbuffer options : standard buffersii) mv:-range :0 to +1999mv resolution: 1 mv or betteraccuracy :+1or- 1mv or betteriii) temperature range : 0.0 to 99 c or better resolution:0.1 c or betteraccuracy :+0.5 c or -0.5 c or betteriv) electrode specification single junction ,body-plastic /unbreakable, gel filled electrode atc probe and electrode stand should also be provided.v) meter features 1) lcd/ led display 2) dual display of ph or mv with temperature 3) with auto buffer recognition 4) off set/slope should be displayed 5) power 230v +10% or -10% 6) buffer solutions 7.0, 4.0. 9.2 ph (100ml minimum) should be provided. 7) should provide all accessories for smooth functioning of the equipment. 8) hard copy of user manual with instrument specification 9) warranty:1 year for the meter and 6 months for electrodecalibration at the time of installation to be done by the supplier., od121755/2025-2026:supply and installation of best quality isi marked digital jar test apparatus with 1) no. of stirrers -6 minimum 2) rpm- 25 to 200 rpm or better 3) capacity of single stirrer unit-1 l 4) control -digital control (digital timer & r.p.m counter) 5) stirrer paddle material (with appropriate corrosion protective coating) - stainless steel 6) power single phase (220 -240 volts) 7) illumination -fluorescent tube ; illumination should not contribute heat to the system. 8) warranty period -2 years installation to be done by the supplier. , od121754/2025-2026:supply and installation of micro controller based digital nephelo turbidity meter specifications:1. range : 0 to 1000ntu 2. range selection manual /automatic 3. resolution . 0.1 ntu or better 4. accuracy +3% or -3% or better 5. calibration : 4 points minimum (manual/auto selection) 6.light source : led/tungsten halogen lamp 7. detector : photodiode 8. display :lcd/led 9. power :230v (+10% or -+10%),50 tom 60-hz 10.accessories matching test tubes(4 nos minimum ) and light shield ,1000ntu solution 500ml minimum 11. instrument manual with specification details(hard copy) 12. warranty 2 years for the entire instrument calibration at the time of installation to be done by the supplier.
Tender For kerala water authority-funds-water quality testing-supply of lab equipment at various wtps under ws section , chiranickal-chiranickal and malankavu wtps - procurement of equipments, od121825/2025-2026: supply and installation of microcontroller based ph meter with 3 point calibrationi) ph:-range : 0.00 to 14.00 ph or betterresolution: 0.01or betteraccuracy:+0.02 or -0.02 ph or bettercalibration points: 3 points minimumbuffer options : standard buffersii) mv:-range :0 to +1999mvresolution: 1 mv or betteraccuracy :+1or- 1mv or betteriii) temperaturerange : 0.0 to 99 c or betterresolution:0.1 c or betteraccuracy :+0.5 c or -0.5 c or betteriv) electrode specificationsingle junction ,body-plastic /unbreakable, gel filled electrodeatc probe and electrode stand should also be provided.v) meter features1) lcd/ led display2) dual display of ph or mv with temperature3) with auto buffer recognition4) off set/slope should be displayed5) power 230v +10% or -10%6) buffer solutions 7.0, 4.0. 9.2 ph (100ml minimum) should be provided.7) should provide all accessories for smooth functioning of the equipment.8) hard copy of user manual with instrument specification9) warranty:1 year for the meter and 6 months for electrodecalibration at the time of installation to be done by the supplier, od121826/2025-2026: supply and installation of micro controller based digital nephelo turbidity meterspecifications:1. range : 0 to 1000ntu2. range selection manual /automatic3. resolution . 0.1 ntu or better4. accuracy +3% or -3% or better5. calibration : 4 points minimum (manual/auto selection)6.light source : led/tungsten halogen lamp7. detector : photodiode8. display :lcd/led9. power :230v (+10% or -+10%),50 tom 60-hz10.accessories matching test tubes(4 nos minimum ) and light shield ,1000ntusolution 500ml minimum11. instrument manual with specification details(hard copy)12. warranty 2 years for the entire instrumentcalibration at the time of installation to be done by the supplier, od121827/2025-2026: supply and installation of best quality isi marked digital jar test apparatus with1) no. of stirrers -6 minimum2) rpm- 25 to 200 rpm or better3) capacity of single stirrer unit-1 l4) control -digital control (digital timer & r.p.m counter)5) stirrer paddle material (with appropriate corrosion protective coating) - stainlesssteel6) power single phase (220 -240 volts)7) illumination -fluorescent tube ; illumination should not contribute heat to thesystem.8) warranty period -2 yearsinstallation to be done by the supplier
Tender For kerala water authority-funds-water quality testing- supply of lab equipments at pampooripara wtp -under ph section pathanamthitta - procurement of equipments, od122174/2025-2026: supply and installation of microcontroller based ph meter with 3 point calibrationi) ph:-range : 0.00 to 14.00 ph or betterresolution: 0.01or betteraccuracy:+0.02 or -0.02 ph or bettercalibration points: 3 points minimumbuffer options : standard buffersii) mv:-range :0 to +1999mvresolution: 1 mv or betteraccuracy :+1or- 1mv or betteriii) temperaturerange : 0.0 to 99 c or betterresolution:0.1 c or betteraccuracy :+0.5 c or -0.5 c or betteriv) electrode specificationsingle junction ,body-plastic /unbreakable, gel filled electrodeatc probe and electrode stand should also be provided.v) meter features1) lcd/ led display2) dual display of ph or mv with temperature3) with auto buffer recognition4) off set/slope should be displayed5) power 230v +10% or -10%6) buffer solutions 7.0, 4.0. 9.2 ph (100ml minimum) should be provided.7) should provide all accessories for smooth functioning of the equipment.8) hard copy of user manual with instrument specification9) warranty:1 year for the meter and 6 months for electrodecalibration at the time of installation to be done by the supplier., od122173/2025-2026: supply and installation of micro controller based digital nephelo turbidity meterspecifications:1. range : 0 to 1000ntu2. range selection manual /automatic3. resolution . 0.1 ntu or better4. accuracy +3% or -3% or better5. calibration : 4 points minimum (manual/auto selection)6.light source : led/tungsten halogen lamp7. detector : photodiode8. display :lcd/led9. power :230v (+10% or -+10%),50 tom 60-hz10.accessories matching test tubes(4 nos minimum ) and light shield ,1000ntusolution 500ml minimum11. instrument manual with specification details(hard copy)12. warranty 2 years for the entire instrumentcalibration at the time of installation to be done by the supplier., od122175/2025-2026:supply and installation of best quality isi marked digital jar test apparatus with1) no. of stirrers -6 minimum2) rpm- 25 to 200 rpm or better 3) capacity of single stirrer unit-1 l4) control -digital control (digital timer & r.p.m counter)5) stirrer paddle material (with appropriate corrosion protective coating) - stainlesssteel6) power single phase (220 -240 volts)7) illumination -fluorescent tube ; illumination should not contribute heat to thesystem.8) warranty period -2 yearsinstallation to be done by the supplier.
Tender For supply, installation and trials of laboratory instruments equipment apparatus with training for quality control ii division at siliguri, p.w.(roads) directorate - nomenclature of machine/instrument and work required: supply, of only vacuum pump cum controller required for existing digital 4 station vacuum indicator for absolute viscosity test. the same will have to he installed on the existing machine and after installation, necessary trials are to be carried out. relevant is code: is: 1206: 2022 (part ii). specification: the pump connected with the vacuum system should be capable of maintaining a vacuum within 2 0.05 cm of the desired level up to and including 30 cm of mercury, and should have the capability of holding the desired pressure throughout the period of a particular test. the pump should have both analogue (with divisions of 0.05 cm of hg) and digital pressure gauge (capability of displaying minimum of 0.05 cm of hg). the vacuum pump controller should be supplied with a 4-position manifold to apply vacuum simultaneously up to four positions and perform viscosity determinations. equipped with dedicated on/off switches for each position and supplied with blue silicon tubing. the pump should have the capability of withholding the pressure set for tests and also maintain it throughout the test. vacuum pump should be the part of vacuum system [pump should be inbuilt with in the vacuum system along with analogue and digital display of vacuum). note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of q.c.-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply, installation of u-tube, modified reverse flow viscometer for opaque liquid required for kinematic test of bitumen. details: tube no. 6 & 7 with 01 no. stand each. relevant is code: is 1206 (part 3): 2021 specification: note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of qc-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply & installation of serological water bath. specification: the bath should have double walled structure, having facility of digital controller cum indicator. the bath should have stirring arrangement. inside wall should be of stainless-steel seamless ss 304 seamless, min. thickness 1.0 mm, with rounded corners for easy cleaning with proper drainage system having ptfe valve and hose pipe (15mm inner dia. min). outer wall to be of ms and properly insulated with cfc-free high-density insulation. minimum temp. range is 5°c to 95°c, 20.2°c. size should be minimum 28 l: -600 w 400d 350 h mm; for 8 standard racks, with adjustable height, compatible with common test tubes (10-50 mm dia.) and other bottles/beakers. note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction, nomenclature of machine/instrument and work required: supply & installation of burette stand with clamp specification: boss head & rod (with stainless steel corrosion resistant rod (length 18") the rod diameter is 1 cm and solid black coated support stand base (6"x4"). should be made of high-quality anti-corrosion & rust-proof stainless steel. the base should be padded to prevent scratches on the surface and better gri
Tender For supply of advanced audio visual system : : - display system , cable management sytem , collaboration system , modular switcher with digital extenders , microphone system , digital signal processor , audio reinforcement system , control processor assembly , cables and connectors , equipment rack
Tender For repair and replacement of all internal components of laboratory equipment that sustained damage due to the severe flooding caused by the beas river - repair, removal of silt and cleaning of incubator 36"x24"x24" and replacement of (digital temp. controller. 6 element, d fan motor, sensor. insulation with paint & wiring etc.) including carriage in all leads and lifts., repair, removal of silt and cleaning of existing incubator size of 24"x18"x18" and replacement of (digital temp. controller, 6 elemen fan motor, sensor, insulation with paint, wiring etc.) including carriage in all leads and lifts., repair, removal of silt and cleaning of existing hot air oven size of 18"x18"x18" and replacement of (digital temp. controller. 6 element. fan motor, sensor, insulation with paint, wiring etc.) including carriage in all leads and lifts., repair, removal of silt and cleaning of existing laminar air flow,size of 4x2x2 and replacement of (hepa filter, pre filter. uv light 1 nos, fluorescent light, centrifugal blower motor with paint i nos wiring, etc.) including carriage in all leads and lifts., repair, removal of silt and cleaning of existing biosafety cabinet, size of 5x2x2 and replacement of (hepa filter, pre filter, uv light 1 nos, fluorescent light, centrifugal blower motor with paint 1 nos wiring, etc.), repair, removal of silt and cleaning of existing autoclave vertical and replacement of (element, psi control switch, water level switch, pressure gauge, safety valve, wiring, etc) including carriage in all leads and lifts., repair, removal of silt and cleaning of existing lab refrigerator and replacement of(complete cooling unit with temperature controller) wiring etc. including carriage in all leads and lifts., repair, removal of silt and cleaning of existing water bath and replacement of(heater, pilot lamp, thermostat, wiring etc) including carriage in all leads and lifts., repair, removal of silt and cleaning of colony counter and replacement of (mother board. display, electrode wiring etc). including carriage in all leads and lifts., repair, removal of silt and cleaning of water distillation glass part including carriage in all leads and lifts.