Tender For supply of current transformer (tfilm) test unit as following specification: 1) current injection up to 600a ac (continuous rating). 2) output current digital display range 0-600a ac with resolution of 1a. 3) digital ammeter of range of 0-10a resolution of 0.1a, with leads having crocodile clips at end. 4) output terminals should be at lhs and rhs of the kit in the front side. 5) mcb to be provided for input side protection. 6) test kit should be compact enough. note: item to be supplied along with nabl calibration certificate for digital output current meter (600 amp ac) and digital input current meter (10 amp ac). [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of ivus nirs , high end echo machine with tee probe and 3d echo , pulsed field ablation console with 03 complete catheter kit , oct , orbital atherectomy - oad pump with 10 complete catheter kit , 10 multipara patient monitors with central monitoring station and remote viewing , portable echo machine , rota ablator , ambulatory blood pressure monitoring , treadmill test equipment , 48 hour holter machine , head up tilt test hutt , single chamber temporary pacemaker pulse generator , 12 lead ecg machine , pft - pulmonaryfunctiontestmachine , defibrillator (q2)
Tender For bid to ras bid to ras corrigendum : supply of solution , hydroquinone 2percent ointment , hydroxy methyl cellulose eye gel , hydroxyurea 500 mg cap , hydroxyzine 10 mg tab , hydroxyzine 25 mg tab , ibuprofen plus cholorzoxazone plus pcm tab flexon mr , ibuprofen 400 mg tab , ibuprofen gel tube of 20 gm , iguratimod 25 mg tab , imeglimin 500mg tab , imipramine 25 mg tab , indomethacin 25 mg cap , indomethacin 75mg cap , inj denosumab solution 60 mg slash ml prollia , inj dexamethasone 2 ml vial , inj dextorse 5percent , inj dicyclomine 20 mg , inj dopamine hcl 40 mg slash ml 5 ml , inj frusemide ip 20 mg slash ml , inj hepatitis b 10ml , inj hydrocortisone sod succ 100 mg , inj insulin aspart 100iu slash ml novo rapid pen , inj levocarnitine 500 mg , inj methylcobalamin 1000mcg plus vitamin b6 pyridoxine 100mg plus nicotinamide 100mg neurobion , inj metronizadole iv , inj romiplostim 250 mcg , inj tramadol , insulin aspart 30percent plus insulin aspart protamine 70percent 100iu slash ml injection novomix 30 flexpen , insulin humalog lispro inj recombinan dna origin 100iu slash mlcartidge , insulin isophane slash nph 70percent plus human insulin slash soluble insulin 30percent human mixtard 70 slash 30 inj , insulin syringe disposable , ipravent respules , isabgol slash ispaghula husk 3 point 5 gm , isosorbid 5 mg monontrate 30 mg tab , isosorbid mononitrate 10 mg tab , isosorbid mononitrate 20 mg tab , isosorbide dinitrate 10 mg tab , isosorbide dinitrate 5 mg tab , isosorbide mononitrate 30mg tab , ivermectin 12mg tab , ivermectin 6 mg tab , ketoralac 0 point 2percent e slash d , ketorolac 10 mg tab , labetalol 100mg tab , lacosamide 100mg tab , lacosamide 200mg tab , lactitol 10gm plus ispaghula 3 point 5gm powder , lamivudine 150 mg tab , lamivudine 150mg plus zidovudine 300mg plus neverapine 200mg tab , lamotrigine 100mg tab , lamotrigine 25 mg tab , lamotrigine 50 mg tab , lenvatinib 10 mg tab , lenvatinib 4mg tab , levodopa 100mg plus carbidopa 10mg tab , levodopa 100mg plus carbidopa 25mg tab , levoflox 500 mg tab , lignocain plus gabapentin oint , linezolid 600 mg tab , liq paraffin 100 ml bott , lithium carbonate 300 mg cap slash tab , lithium carbonate prolonged r 450 mg tab , loperamide 2 mg tab , loratadine 10 mg tab , lorazepam 1 mg tab , lorazepam 2 mg tab , l ornithine l aspartate tab hepamerz , lornoxicam 8 mg plus thicolchicoside 4 mg tab tab , lotepredenol etabonate 0 point 5percent bott of 5 ml , glass test tube 100x12 mm , hba1c oncall pearless 20 test x 1 kit , kit for estimation of albumine , kit for estimation of calcium , marking pen , plastic test tube rack , semi auto analyser wash solution erba wash , steel test tube rack , tissue paper roll , torniqate , vaccutainer needel holder , vaccutainer needel , urine analyzer strips laura erba , kit for estimation of alkaline phosphate , kit for estimation of bilirubin point , kit for estimation of cholestrol point , kit for estimation of glucose point , kit for estimation of hdl point , kit for estimation of triglyceride point , kit for estimation of uric acid point , kit for estimation of b point glucose , kit for estimation of b point urea , kit for estimation of s point g point o point t , kit for estimation of s point g point p point //bid details 2 / 148 t , kit for estimation of crp , kit for estimation of widal , kit for estimation of s point amylase , hcv kit of 25 cards , hbsag kit of 25 cards , malaria kit of 25 cards , dengue serology rapid kit pkt of 25 , urine container , disposable esr pipette , glass slide , glass test tubes 75 x 10 mm , micro cover glass slip , dettol , tissue roll , disttled water , microtips 5 ul 50 ul pkt of 1000 , microtips small 10 ul 50 ul pkt of 1000 , microtips 50 ul 200 ul pkt of 1000 , microtips large 100 ul 1000 ul pkt of 1000 , microtips 200ul 1000 ul pkt of 1000 , vaccautainer s point floride tube , vaccautainer yellow gel tube , vaccautainer red top plain tube , vaccautainer e point d point t point a k3 tube , p
Tender For corrigendum : supply of e4263000 01 universal secondary injection test kit (iec 61850 compliant) with software & laptop as p , 02 universal secondary injection test kit (iec61850- 8-1 and iec 61850-9-2 compliant) with software &
Tender For corrigendum : supply of primary current injection test kit 0-500a variable for testing of current transformers and all electrical equipments
Tender For corrigendum : supply of calibration and installation of maintenance testing kits include the following equipment: dcrm (dynamic contact resistance measurement) ultima (3ch), (make: scope, model no. dcrm ultima 3ch; hisac ultima, make: scope, model no. hisac ultima; crm contact resistance meter, make: scope, model no. 200 b+; wrm contact resistance meter, make: scope, model no. trm 104; and the primary current injection testing kit prima 02, make: scope, model no. prima 02 or nabl-accredited test laboratory or similar) . the detailed quantity of all calibration kits shall be as per annexure a. calibration for all equipment shall be carried out by the oem or a nabl-accredited test laboratory, and the calibration shall be performed at the sse/ trd/kmz office in the jabalpur division. all items shall carry a warranty of 12 months from thedate of delivery. [ warranty period: 12 months after the date of delivery ]