Web Analytics Made Easy - StatCounter

Pulse Lavage System Tenders

Get complete information related to latest Pulse Lavage System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pulse Lavage System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pulse Lavage System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42579205 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr

CTN :43127693 Due date: 24 Dec, 202524 Dec, 2025 95.41 Lacs
Tender For supply of 611b dglp ifa ortho consumables dglp gem 24 2025 26 c c - 2. 7mm justa articular plate left and right 03 hole 04 hole 05 hole 06 hole , lc lcp 3. 5mm 6 to 14 holes titanium with screws , lc lcp 4. 5 per 5. 0 broad 8 to 14 holes titanium , skin stapler with 35 per 55 stainless steel staples , waterless surgical hand atiseptic solution with moisturizers 500ml bottles consist of chlorhexidine gluconate 1 percent solution and ethyl alcohol ip 61 percent w per w , single knitted fiber glass pre padded splint 12. 5 cm x 4. 6m roll pre padded single interlick knitted slab of 7 layer fiber glass woven with interlocking performance technology , highly stretchable crimped weave cotton bandages with polyamide fibers , cement bipolarhispprosthese doubletripl taperedcobaltchrom polisfemoral stem12 14taper41 43mm43 44mm45 46mm47 48mm biplarhed cobaltchrom outershel etosterilduhmwpecobalt chrom hedmolecularrestrictor , k wire cutter universal , bandage plaster of paris 10cm x 3 meters , bandage plaster of paris 15cm x 3 meters , cling drape , sterile disposable shoulder arthroscopy drapes pack with fluid collection bag with port , sterile disposalble hip drapes pack isto pack should have one u drape and 4 sterile sheet of water proof material , knee arthroscipy drape pack consist of knee arthroscopy drape sheet with drainage pouch nonwoven imprevious u drape cling film patient legging pouch tubing for drainage per suction cautery bag , four point rigid knee orthrosis knee brace , postoperative elbowothotic paddedline aluminiumcuffs extensionlimitation 0. 105degree flexionlimitaiton 0 120deg locklimitaiton 0. 90degadjust 15deg handgrip antisupination pronation arm barleft univer , dfn distal femoral nail short and long nail size 9 10 11 with bolts , disposable pulse lavage system , bone cement antibiotic loaded 40 gm , leg u drape , trauma pack lower limb consist of o drape gripper size 2 x 3. 5 mtr imprevious u drape patient legging cautry bag cling film , trauma pack upper limb consist of o drape gripper s 1. 6 x 2. 4 mtr imprevious u drape , interlocking nail for humerus size 6. 5 to 7. 5mm with locking bolts , flexible reaming set ao type 8 14mm with 0. 5mm increment with front and side cutting , plaster cutting saw blade , arthroscopy drape spun lace fabric water repellent size 240 x 240cm elastic aperture 8 cm dia plastic film tunnel 80 cm perimeter 60 cm depth , ankle orthotic air column in bilateral sides ankle joint archilles tendonhaving inernally inbuild pumpfor air inj in aircolumns skin friendlymaterial for absorbingmoisture elasticstrap tension magt //bid details2 / 43

CTN :43020665 Due date: 31 Dec, 202531 Dec, 2025 NA
Tender For tender for rate contract of orthopedic arthroplasty implants - arthroplasty implants, basic high flex total knee replacement system: total condylar posterior stabilized (ps)/ cruciate retaining (cr) design anatomic femoral component of various sizes and having design to accommodate high flexion, can accept different sizes and thickness of fixed bearing inserts. fixed bearing cemented tibial tray in various sizes, can accept different sizes of fixed bearing inserts of various sizes & thickness. fixed bearing ps/cr polyethylene insert in different sizes & thickness compatible with various sizes of fixed bearing tibial tray. high viscosity antibiotic loaded bone cement 40 gm. with one pulse lavage system. disposable items consist of the items mentioned below: pulsatile lavage. iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos) stockinet. leg o drape, water impermeable along with screen. surgical oscillating saw blade.orthopaedic gloves with roughened palmer surface., high flex total knee replacement system with attachment of one tibal wedge and one tibial intramedullary extension rod assembly * total knee replacement system, posterior stabilized (ps), design femoral component of various sizes and having design to accommodate high flexion, can accept different sizes and thickness of fixed bearing inserts. fixed bearing cemented tibial tray in various sizes with attachment of one tibial wedge and one tibial intramedullary extension rod assembly, can accept different sizes and thickness of fixed bearing inserts. fixed bearing ps/cr polyethylene insert in different sizes & thickness compatible with various sizes of fixed bearing tibial tray. patella with pegs made of polyethylene available in various sizes. high viscosity antibiotic loaded bone cement 40 gm. disposable items consist of the items mentioned below: pulsatile lavage. iodinated surgical adhesive drape (large size) skin stapler., modular bipolar hemiarthroplasty system. modular bipolar shell containing hdpe inbuilt of different sizes (39-53mm outer diameter and 22/28 mm inner diameter in three different neck lengths). cemented tapered femoral stem (different sizes: extra small, small, medium, and large). cement restrictor centralizer 1 packet of bone cement 40 g. disposable items consist of the items mentioned below: iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos ) stockinet. leg u drape, water impermeable along with screen. ethibond5 : 1 pack with 4 threads.orthopaedic gloves with roughened surface 6 pairs., non-cemented total hip system (metal head on poly) non-cemented ha/porous coated stem having various sizes, can accept multiple offsets of metal heads (small/medium/large/extra-large) with diameter of 28/32/34/36. non cemented porous coated acetabular cup made of titanium alloy available in various sizes, with locking mechanism to accept polyethylene liner of various sizes & diameter (28/32/34/36) must have holes in dome area for screw fixation. the polyethylene liner should be highly cross-linked with various diameters & sizes compatible with acetabular cup & can accept various heads. 3 cancellous screws made of titanium to fix the cup into the acetabulum. disposable items consist of the items mentioned below: iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos ) stockinet. leg u drape, water impermeable along with screen. ethibond 5: 1 pack with 4 threads.orthopaedic gloves with roughened surface 6 pairs., non cemented total hip system (ceramic head on poly ) * non cemented ha/porous coated stem having various sizes, can accept multiple offsets of metal heads (small/medium/large/extra large) with diameter of 28/32/36. ceramic heads (made of delta ceramic) having variable offset (small/medium/large/extra large) with diameter of 28/32/36 mm compatible with the stem. non cemented porous coated acetabular cup made of titanium alloy avai
 Loading, Please wait...

Connect us via What's Up