Get complete information related to latest Pump Spares Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pump Spares Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pump Spares Repair Tenders.
Tender For running, maintenance and operation of 11/0.415 kv sub-station equipments ,dg set ,internal, external and high mast lighting, submersible pump, refiiling of fire extinguisher and annual maintenance contract air conditioning ,water etc at rskp, dda.
Tender For running, maintenance and operation of 11/0.415 kv sub-station equipments ,dg set ,internal, external and high mast lighting, submersible pump, refiiling of fire extinguisher and annual maintenance contract air conditioning etc mdcsc ,dda
Tender For running, maintenance and operation of 11/0.415 kv sub-station equipments ,dg set ,internal, external and high mast lighting, submersible pump, refiiling of fire extinguisher and annual maintenance contract air conditioning ,water cooler and ro units at
Tender For supply of seal valve stem part no 3943888 or 5253590 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761558 , valve exhaust part no 3969637 or 4089762 for engine assy, model-qsl-9, make- cummins suitable for engine sl no-73142859 and 73761559 , valve intake part no 3970727 or 4089761 for engine assy, model-qsl-9, make-cummins suitable for engine sl no- 73142859 and 73761560 , valve insert part no 3940152 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761561 , valve insert part no 3968074 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761562 , collect valve part no 3900250 for engine assy, model-qsl-9, make- cummins suitable for engine sl no-73142859 and 73761563 , guide valve stem part no 4934063 for engine assy, model- qsl-9, make-cummins suitable for engine sl no-73142859 and 73761564 , hose flexible part no 3282167 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761565 , pulley alternator part no 3972808 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761566 , cylinder head gasket part no 3967059 or 4981796 for engine assy, model-qsl-9, make-cummins suitable for engine sl no- 73142859 and 73761567 , oil pan gasket part no 3973509 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761568 , piston ring set part no 4089644 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761569 , lower engine gasket set part no 4089889 for engine assy, model- qsl-9, make-cummins suitable for engine sl no-73142859 and 73761570 , upper engine gasket set part no 4089978 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761571 , fuel pump assy.,part no 3975375 for engine assy, model-qsl-9, make- cummins suitable for engine sl no-73142859 and 73761572 , pipe air transfer part no 3883977 for engine assy, model- qsl-9, make-cummins suitable for engine sl no-73142859 and 73761573 , gasket oil sump part no 3939352 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761574 , gasket oil cooler part no 3918174 for engine assy, model-qsl-9, make- cummins suitable for engine sl no-73142859 and 73761575 , gasket oil cooler part no 3929011 for engine assy, model- qsl-9, make-cummins suitable for engine sl no-73142859 and 73761576 , gasket oil cooler part no 3992092 for engine assy, model-qsl-9, make-cummins suitable for engine sl no-73142859 and 73761577
Tender For bid to ras supply of motor control panels starter panels - brake dust collector motor control panel , stator heater control panel , gov and miv opu pump motor control panel , raw water cw pump motor control panel , treated water cw pump motor control panel , top cover drainage pump motor control panel , oil leakage unit mcp , hs lubrication pump mcp , dewatering pump motor control panel , drainage pump motor control panel , flood protetion pump motor control panel , hp compressed air motor control panel , oil leakage unit motor control panel for bf valve , bfv opu motor control panel
Tender For supply of esp collecting and emitting rapping mechanism complete gear box for bm-u-1, 250 mw. at, tps parli vai, procurement of coal feeder door gaskets at bm u-1, 250 mw., tps parli vai, procurement of seal air fan and various types of coupling for boiler side auxiliary in u-6 and 7 at bm-1, 250 mw., tps parli vai , procurement of carbon brush for ground fault detection system of generator rotor at em-1, 250 mw., tps parli vai. , supply and commissioning of end suction horizontal centrifugal dilute acid / alkali loading, unloading pump at tm-1, 250 mw., tps parli vai, work of providing and applying anticorrosive acid resistance primer for apron feeder structure at chp u-6, 7 and 8, 250 mw., tps, parli vai, work contract for various works during aoh at i add c-2, 250 mw. tps parli vai., procurement of inching jaw clutch and its spare for coal mill bbd-4772 at bm-1, 250 mw. tps parli vai, procurement of air receiver tank for dry fly ash evacuation system at ahp-8, 250 mw. tps, parli vai, two year work contract for man power assistance for various day to day shift work at et u-8, 250 mw, tps parli vai, procurement of 36" gravimetric coal feeder spares required at bm u-8, 250 mw. tps parli vai, procurement of upper and lower journal assembly housing for coal mill xrp-903 required for aoh at bm u-8, tps, parli vai, work of providing and fixing of coal feeder conveying optimization work at bm-2, 250 mw. tps, parli vai.
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s