Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; power house equipment; service provider - pump impeller ss 316, pump shaft en8, ball bearing 6310-c3 (skf/fag), shaft gland sleeves, packing and o-rings, gland packing, shaft coupling (rb-285/11) rb (rubber bushed) 285-11 pin bush type flexible coupling motor and pump side complete set including boring, making key way and fixing, neck-rings (suitable material), bearing brackets (suitable material), removal of pump from foundation and shifting to firm's workshop for repair of pump including housing, assembly and shifting back to site, installation, trial run and commissioning.
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - supply installation testing commissioning of hsc pump starter control panel for 100hp split case pumping plant along with complete protection for pumping plant with required necessary armoured cable, copper cable, jointing kits, earthing for panel, pump, motor &foundation for the starter unit with proper alignment with in coming power supply up to the pump room as per direction of e/i complete in all respect
Tender For supply of carry out b check servicing of 320 kva dg set as per specifications , replacement fauly battery and sf of 12v 130 ah battery with 2 year waranty , sf 24v smps battery charger 10 16a , repairing of pumps as required , repair 3 hp borewell pump incl pull out and lowering , attending fault with monor repair and service for 7 or 7.5 tr pakckage ac , repair of split ac incl gas charging except compressor , rewinding of condenser motor for package ac unit 3 phase , supply and charging r22 gas incl notrogen pressure test for package ac units , repalcment of time relay circuit for package ac units , replacement of control card in existing afd system with testing as reqd , replacement of zone card in existing afd system with testing as reqd , replacement of power card in existing afd system with testing as reqd , sf 12v 26ahm battery for existing afd system with testing as required. , laying pvc or xlpe cable in ground upto 35 sq mm as required , laying pvc or xlpe cable on wall or surface upto 35 sq mm as required , supply and making cable end termination for 2 core 6 sq mm al cond cable , testing of existing co2 type fire extinguihsers , refilling of existing co2 type fire extinguihsers , replacment of faulty compressor of extg split ac units with gas charging
Tender For corrigendum : supply of frequently used spares for alds - kalvacha (model: lpgk220f/lpgk 230), dispenser keypad, electronic cpu, dispenser display card, dispenser totalizer card, relay board, dispenser flow / piston meter:, dispenser flow meter pulsar:, supply of communication cable for dispenser:, mechanical seal for dispenser flow meter:, differential valve repair kit for dispenser, dispenser flow meter head o ring set, solenoid valve with coil, dispenser pressure gauge, breakaway coupling including anchoring arrangement for dispensing hose, differential valve, carbon bush & shaft, yenen- regismart ii, dispenser keypad, electronic cpu, dispenser display card, dispenser power card, dispenser totalizer card, dispenser flow / piston meter:, dispenser flow meter pulsar:, supply of communication cable for dispenser:, magnetic coupling for dispenser flow meter, differential valve repair kit for dispenser, dispenser flow meter head o ring set, dispenser diapharam, rtd sensor, atc card, filter element for dispenser, fas-230/fas-pdc400, dispenser keypad, electronic cpu, dispenser display card, dispenser power card, dispenser flow meter pulsar:, magnetic coupling for dispenser flow meter, differential valve repair kit for dispenser, dispenser flow meter head o ring set, eurostar, dispenser keypad, electronic cpu, dispenser display card, dispenser power card, dispenser totalizer card, dispenser flow / piston meter:, dispenser flow meter pulsar:, supply of communication cable for dispenser:, mechanical seal for dispenser flow meter:, differential valve repair kit for dispenser, dispenser flow meter head o ring set, filter element for dispenser, opw t3, dispensing nozzle, dispensing nozzle teeth, dispensing nozzle lever lock, dispensing nozzle bush, dispensing nozzle handle, dispensing nozzle sleve, l&t, l&t single phase preventor ma 51bc, l&t contactor mnx 18, l&t mn2 olr, schneider, schnider thermal overload relay lre 14 7a-10a, schneider mushroom head push button as542n, schnider contactor lc1 e12 10, 30ma elcb, supply and installation of plc for double tank alds panel with program, smps 24v, honor & reputed make, supply & installation of digital plc for double tank alds panel with program-he-exl1e4. exl6e series ocs with high-density dc/dc i/o.twenty-four (24) digital inputs compatible with 12v/24vdc - four inputs can be used for 10khz high speed counting.sixteen (16) dc outputs - 0.5a per point - two (2) outputs can be used as pwm/pulse outputs. two (2) 10-bit analog inputs selectable between 0-10v and 4-20ma. with program, supply, fixing and wiring of two tanks . dispenser - relay based, esd function, unloading operation, dispensing operation, tanks interlocking between two tanks and mode selection, hla two tanks, panel internal wiring, routing, testing and installation., polycab/orbit, earthing wire 6mm2 copper flexible, earthing wire 16mm2 copper cable, sheilded cable 3c x 1.5sq mm, sheilded cable 6c x 1.5sq mm - armoured, sheilded cable 2c x 1.5sq mm - armoured, sheilded cable 3 c x 2.5sq mm - armoured datasheiled, copper armoured cable without sheilded -3 core x 1.5 sqmm, copper armoured cable without sheilded - 2 core x 1.5 sqmm, copper armoured cable without sheilded - 6 core x 1.5 sqmm, copper armoured cable without sheilded - 6 core x 2.5 sqmm, baliga, flp dummy for jb, emergency button flp, pump on/off switch flp, 4 way junction box, flp double compression gland 2c x1.5sqmm, flp double compression gland 3c x2.5sqmm, flp double compression gland 6c x2.5sqmm, nonflp double comp. gland 2x1.5sqmm, nonflp double comp. gland 2x2.5sqmm, nonflp double comp. gland 3x1.5sqmm, nonflp double comp. gland 3x2.5sqmm, nonflp double comp. gland 6x2.5sqmm, fuji/schnider - vfd, supply & installation - vfd (incl of cable supply , glands and other allided works), fuji/krycard, 1kv onine ups, ira, tyre inflator - full set, 15 mts hose & nozzle, floor mounting stand, cpu card, coil set, rochester, rochester ga
Tender For corrigendum : special repair wk to em installations power house pump house a b c with allied works at mil stn haldwani under ge ranikhet - spl repair wk to e/m installations (power house/pump house) ‘a’, ‘b’, & ‘c’ with allied works at mil stn haldwani under ge ranikhet
Tender For corrigendum : special repair of main cable from power house to pump house and from power house to officers enclave of sirsa at katihar mil stn under age(i) katiharstation under age (i) katihar
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - nuclear power plant kaiga generating station kgs 1 and 2; rewinding of 6600 volt 1450kw boiler feed pump bfp motor of kgs 1 and 2, electrical system or installation, pow..
Tender For repair of 6 nos of pts at (1) near dwarkapuri bus stand, (2) opposite asi office, (3) near petrol pump sec-1 (4) near police, (5) opposite power house, (6) near veterinary hospital campus by sanitary work, tiles work, roof repair etc. in ward no.