Tender For schedule for all electrification work (air conditioning,sound system,cctv,fire alarm,fire fighting pump,stage lighting, s/f of diesel generator set etc. & all other related electrical work) of 450 & 1380 seater auditorium at pt. jnm medical college raipur (c.g.)
Tender For general- ward 26 for burns icu attached-setting up of step down to ward 26for burns icu attached to government medical college hospital thiruvananthapuram. air conditioning system-electrical ac work
Tender For corrigendum : construction of proposed hostel building for medical students of ipgmer-sskm hospital at 3, lee road kolkata ----- supply, installation, testing and commissioning of air conditioning system.
Tender For corrigendum : central air conditioning system for blood bank of midnapore medical college and hospital, paschim medinipur. (electrical work).
Tender For a) ch- renovation works required for provision of new ductable air conditioning system for ward no.5 & 9, opd medical store, physiotherapy ward at ch/lgdb) replacement of codal life completed ac plant system in new mot in ch/lgdc) replacement of codal life completed ac plant system in gyneac ward in ch/lgd
Tender For supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exhaled carbon dio
Tender For supply of providing and fixing of fire proof uniform in exiting mobile van as per given specification , providing and fixing of pulaski tool or rakes in exiting mobile van as per given specification , providing and fixing of fire proof shoes ain exiting mobile van as per given specification , providing and fixing of portable air blowers in exiting mobile van as per given specification , providing and fixing of other fire fighting equipments in exiting mobile van as per given specification , providing and creation of general controlled burning and fire line as per given , providing and creation of first class fire line as per given , providing and creation of second class fire line as per given , providing and creation of communication system and mis development and watch towers and water storage structures and control rooms and fg barracks and inspection huts , providing and fixing of truck mounted water tanker as per given specification , garbage bags (q2) , bio - medical waste collection bags (biohazard bags) (q2)