Get complete information related to latest Pumps Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pumps Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pumps Spares Tenders.
Tender For balance work of construction, testing and commissioning of r.c.c. elevated service reservoir of 100 kl capacities & staging 12 mt. & 25 kl capacities gsr at manpur including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber & providing, laying, jointing, interconnection, testing and commissioning of 90/110/140/160 mm dia upvc class 6/10 kg/sqcm pipe, 63/75 mm dia class 6 kg/sqcm hdpe pipe with suitable joints, valve specials and all fittings including all allied civil works, supplying & installation of energy efficient isi marked required capacity single phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with control panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, ss/nylon wire rope connection cable including electric connection from cspdcl, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (f.h.t.c) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under single village of piped water supply scheme under jal jeevan mission for village manpur bhaisbod sudiyal block manpur district- mohla manpur a.chowki
Tender For balance work of construction, testing and commissioning of r.c.c. elevated service reservoir of 70 kl capacities & staging 12 mt. at goplinchuwa & 40 kl capacities & staging 12 mt. at kaudutola including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber & providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia upvc class 6/10 kg/sqcm pipe, 63/75 mm dia class 6 kg/sqcm hdpe pipe with suitable joints, valve specials and all fittings including all allied civil works, supplying & installation of energy efficient isi marked required capacity single phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with control panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, ss/nylon wire rope connection cable including electric connection from cspdcl, construction of brick masonry switch room , construction of boundary wall around the over head tank, installation of electro chlorinator, construction of chlorinator room, providing functional household tap connection (f.h.t.c) in individual households and government institution etc. complete with 03 months trial run, operation & maintenance for 06 months under retrofitting of piped water supply scheme under jal jeevan mission for village goplinchuwa karamtara kaudutola block a.chowki district- mohla manpur a.chowki
Tender For operation and maintenance of storm water pumps, dg sets at various locations (shahdara) under pwd m251, delhi. (sh- repair/ replacement of defective/non repairable panel at c-3, nand nagari pump house under pwd sd m-2533)
Tender For water supply scheme (m.well cwr) at uriham para for installation of pump set, electrical panel board to be install in m.s. (18 swg) kiosk, commissioning of the m. well in/c domestic connection under atal jaldhara mission
Tender For annual maintenance of monoblock pumpset, openwell monoblock pump & submersible pump set with starter panel installed in non residential section-2,3 & 4 (sector-9 to 14)of capital project electriacl sub div-23, gandhinagar.
Tender For annual maintenance of pressure pumpset, openwell monoblock pump & submersible pump set with starter panel installed in residential section-2,3 &4 ( sector-9 to 14) of capital project electriacl sub div-23, gandhinagar.
Tender For repair/maint of centrifugal pump, monoblock pump, submersible machinery, lt panel and miscellaneous e/m work and improvement of installation at rrrc, lorry road, aepta, dk part-i, ta 105 and eme stn wksp in the area of ge (u) water supply
Tender For corrigendum : tender for supply of operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days iincluding sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications. for first year , operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days including sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications.for second year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for first year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfd drive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for second year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for first year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for second year , repairing damaged insulation of exposed ac ducts by scrapping and cleaning the surface , applying cold bitumin or adhesives , supplying and fixing of 50mm thick thermo coal sheet (eps) and wraped canvas clothes with suitable self adhesive as