Get complete information related to latest Pumps Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pumps Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pumps Tenders.
Tender For supply, installation, testing and commissioning of submersible pump/ monoblock pumps at water emergency filling point at daulatpur and ujwa bps
Tender For maintenance including on and off operation of all electrical equipments of street lights and storm/drainage water pumps at patipukur underpass on jessore road, dumdum
Tender For drilling of 03 nos 125 mm dia nominal bore holes for hand pump and installation of india mark_ii/extra deep well hand pumps complete including construction of platform in rural area of block khetri of division khetri
Tender For drilling of 10 nos 125 mm dia nominal bore holes for hand pump and installation of india mark_ii/extra deep well hand pumps complete including construction of platform in urban and rural area under block udaipurwati, of division khetri
Tender For 31/2025-26 construction and commissioning of (17 nos) 125mm hand pumps at various locations under mla constituency phulera, under jurisdiction of division jobner
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For gr no-05 name of work- estimate for construction of new deep hand-pumps ( india mark-ii) with simple boring, gpt boring & machine drilled boring and construction of platform with 3 meter long p.c.c. drain for providing drinking water in water scarce areas & sc tolas for summer of 2025 at different places in aurangabad district under p.h. division aurangabad. (year :? 2025-26.).