Get complete information related to latest Push Button Station Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Push Button Station Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Push Button Station Tenders.
Tender For design, engineering, manufacturing, inspection and testing at manufacturers works, packing and forwarding from manufacturer place of dispatch and delivery at project site of flameproof and weather proof type pushbuttonstation for our composite work
Tender For procurement of electrical spares for auxiliary section at dharasu power house - contactor coil for contactor mnx-265 , coil voltage 110, make l&t, contactor coil for contactor mnx-325, coil voltage 110, make l&t, cbt-110, 1000 v/ 150 a/ 50 sq mm, make elemex, cbt-170, 1000 v/ 192 a/ 70 sq mm, make elemex, mechanical change-over, 63 amp, make siemens, contactor coil for contactor mnx-110, coil voltage 110, make l&t, contactor coil for contactor mnx-70, coil voltage 110, make l&t, contactor kit for contactor mnx-70, make l&t, contactor kit for contactor mnx-110, make l&t, proximity switch for open & close indication, operating distance- 20 mm, operating voltage- 10-30 vdc, protection- p68/ip69k, direct, spool valve 4port 24 v dc 40kg/cm2 (miv, seal & bypass valve solonite), pushbutton red with no-nc,, pushbuttongreen with no-nc, timer 0-100 second, make siemens, terminal block 60amp. single way, contactor mnx-65/70 amp, coil voltage 110v, with 2no-2nc assy.
Tender For supply of sc050150343 power contactor ac 3e ac 3 9 a 4 kw 400 v 3 pole 230 v ac 50 60 hz auxiliary contacts 1 n , sc050390176 overload relay 7 point 0 to10 a thermal for motor protection size s0 class 10 contactor mounting main ci , sc050150342 power contactor ac 3e ac 3 25 a 11 kw 400 v 3 pole 230 v ac 50 60 hz auxiliary contacts 1 , sc050140161 no of auxiliary 1no type no 3rh2911 1ha10 make siemens , sc050140162 no of auxiliary 1no plus 1nc type no 3rh2911 1ha11 make siemens , sc050140182 surge suppressor varistor with led 127 240 v ac 50 60 hz 70 150 v dc , sc050150345 power contactor ac 3e ac 3 12 a 5 point 5 kw 400 v 3 pole 110 v ac 50 60 hz auxiliary contacts 1 , sc050140183 surge suppressor rc element 48 127 v ac 50 60 hz 70 150 v dc , sc050150346 power contactor ac 3e ac 3 7 a 3 kw 400 v 3 pole 110 v ac 50 60 hz auxiliary contacts 1 no , sc050390178 overload relay 1 point 4 to 2 point 0 a thermal for motor protection size s00 class 10 contactor mounting main c , sc050390177 overload relay 1 point 1 to 1 point 6 a thermal for motor protection size s00 class 10 contactor mounting main c , sc050140181 auxiliary switch can be mounted on the side 2 nc screw terminal for circuit breaker 3rv2 , sc050150344 ac 3 250a tp contactor with 2no plus 2nc 230vac s10 , sc050150350 ac 3 170a contactor with 2no plus 2nc 230vac s8 , sc050150351 ac 3 85a ac 3 230v , sc050150352 power contactor ac 3e ac 3 150 a 75 kw 400 v ac 50 60 hz dc uc 200 277 v plc input 24 v dc , sc050390179 overload relay 50 to 200 a for motor protection size s6 class 10e contactor mounting stand alone ins , sc050140189 contactor relay 82e ) /bid number : gem/2025/b/6617371 * /dated: 29-08-2025 & & / bid document 1 / 24 en 50011 8 no plus 2 nc screw terminal dc operation 24 v d , sc050140190 contactor relay 4 no 24 v dc screw terminal frame size s00 , sc050140188 auxiliary switch on the front 4 no 53 54 63 64 73 74 83 84 current path 1 no 1 no 1 no 1 , sc050140187 aux contactor relay 2no plus 2nc 24 v dc , sc050150349 contactor with 1no 9 a ac 3 24 v dc , sc050150348 contactor 16 a ac 3 230 v , sc050150347 contactor 32 a ac 3 230 v , sc050140186 auxiliary switch block without switch position indicator for attaching on contactors 1 no , sc050140185 auxiliary switch transverse 1 no plus 1 nc screw terminal for circuit breaker 3rv2 , sc050140184 contact block 1 no plus 1 nc screw terminal front plate mounting , sc050150353 power contactor ac 3e ac 3 9 a 4 kw 400 v 3 pole 230 v ac 50 60 hz auxiliary contacts 1 no , sc050150354 power contactor ac 3e ac 3 7 a 3 kw 400 v 3 pole 230 v ac 50 60 hz auxiliary contacts 1 no , sc050130145 siemens contactor 3rt2016 1ap01 1no coil 230v ac , sc050150355 power contactor ac 3e ac 3 16 a 7 point 5 kw 400 v 3 pole 230 v ac 50 60 hz auxiliary contacts 1 , sc050150356 power contactor ac 3e ac 3 32 a 15 kw 400 v 3 pole 230 v ac 5060 hz auxiliary contacts 1 , sc050390180 overload relay 5 point 5 to 8 point 0 a thermal for motor protection size s0 class 10 contactor mounting main ci , sc050390181 overload relay 1 point 4 to 2 point 0 a thermal for motor protection size s00 class 10 contactor mounting main c , sc050150357 contactor relay latched 3 no plus 1 nc 24 v dc screw terminal frame size s00 , sc050430079 switch disconnector fuse 125a as per 3kl8221 5ta00 with hrc fuses
Tender For installation, testing and commissioning of electrical equipments at chp area of rsps2 in tnpl unit i - ht switch board installation, testing and commissioning of the following ht switchgears including the final preparation of foundation, and transporting from employers stores or any other storage area (inside mill) to the place of installation, positioning in place, site assembly of loosely furnished accessories, 11 kv single bus bar board (1 vertical size 800x1500x2400) at + 0.0 m lvl, transformers installation, testing and commissioning including oil filtration & testing of the following transformer, including the final preparation of foundation, and transporting from employers stores or any other storage area (inside mill) to the place of installation, positioning in place, site assembly of loosely furnished accessories. transformer oil to be tested at nabl lab and report to be submitted to tnpl., transformer 2.5mva, 11/0.433kv at + 0.0 m lvl, low voltage power & motor control centersinstallation, testing and commissioning of the following lv pccs including the final preparation of foundation, and transporting from employers stores or any other storage area (inside mill) to the place of installation, positioning in place, site assembly of loosely furnished accessories, chp pcc (panel size 5700x1360x2375 - multisection) at + 6.00 m lvl, chp mcc-1 (panel size 10800x1120x2375 - multisection) at + 6.00 m lvl, chp mcc-2 (panel size 10800x1120x2375 - multisection) at + 6.00 m lvl, chp mcc-3 (panel size 6000x1120x2375 - multisection) at + 6.00 m lvl, mldbs / acdbs/changeover panel, chp acdb (panel size 3120x560x2375 - multisection) at + 6.00 m lvl, chp mldb (panel size 3120x560x2375 - multisection) at + 6.00 m lvl, installation of miscellaneous panels, panels upto 50 kg, panels 51 to 100 kg, panels 101 to 500 kg, panels 501 to 1000 kg, installation of pushbuttonstations/ control stations, installation and commissioning of ordinary, lockable type, emergency stop or start/stop pushbuttonstations to be located near the equipments on steel supports, excluding supply of steel structural supports, cable terminations, earthing., welding sockets, installation, connection, testing and commissioning of thermoplastic polycarbonate 63a tpn with elcb-30 ma + 16a sp with elcb-30 ma industrial type sockets excluding cable termination. (box size 700x400x360mm), installation, connection, testing and commissioning of weather-proof metal clad 20a spn industrial type sockets excluding cable termination., cables, laying, dressing and clamping in trays/walls/ceiling/trenchesvertical laying of the following cables in ready trays, pulling through pipe and fixing of cable tags (aluminium strip number tags), fixing of gi saddles, saddle bars for cable clamping, clamp trays shall be tied by means of nylon ties etc, transportation of cables from employers stores or cable yard or any other storage area (inside mill) to respective plant area , 11 kv xlpe aluminium armoured cables3cx300 sq.mm al. ar. ue xlpe 11kv ht cable (round wire armoured), 1.1 kv, 3c/3.5c/4c xlpe/pvc aluminium/copper armoured/ unarmoured power cables, laying of cables up to 2.5 sq.mm, laying of cables from 6 to 16 sq.mm, laying of cables from 35 to 50 sq.mm, laying of cables from 70 to 120 sq.mm, laying of cables from 150 to 185 sq.mm, laying of cables from 240 to 300 sq.mm, 1.1 kv pvc copper control cables, laying of cable - 12 c x 1.5 sq.mm, end terminations for 11 kv power cablesend terminations for 11 kv xlpe power cables including cutting, stripping of cable insulation, providing compression type terminals, crimping on to the cable and then connecting it ( end termination kit will be supplied by tnpl), 3cx300 sq.mm al. ar. ue xlpe 11kv ht cable (round wire armoured), end terminations for lt power cablestermination of cables and connection of leads for 1.1 kv and lt cables including supply of termination accessories like double compression type brass cable glands, lugs, conn