Get complete information related to latest Putty Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Putty Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Putty Repair Tenders.
Tender For corrigendum : tender for supply of operation and comprehensive maintenance of ems at kadma te build jsr d d - as per item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , sf pvc junction box along with 150 amp 4 way connectors , suppllying xlpe 1.1 kv al 4x10 sqmm cable , suppllying xlpe 1.1 kv al 2x6 sqmm cable , laying of xlpe cable in ground , laying of xlpe cable on wall surface , laying of cable existing rcc/ hume/ metal pipe , sh 40 mm dia g.i pipe medium class ias per nit. , sm end term with brass gland and alum lugs 4 x 10 sq. mm , sm end term with brass gland and alumi lugs 2 x 6 sq. mm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl. 400a fp mccb , 36ka overload rel , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required. , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , supply and replacement of 45 watt street light , supply and replacement of 27 watt street light , dehyd filt & testing of existing trasformer , supplying of new transformer oil , replacement gasket of transformer , replacement lt side stud bush , painting of transformer with good quality synthetic paint , s/f diesel filter with o ring (primary) 160kva d e/a set , s/f lub oil filter with o ring 160kva d e/a set , s/f diesel filter with o ring (secondary) 160kva d e/a set , s/f engine oil(mobil) 160kva d e/a set , sevicing by authorised dealer /oem for160kva dg set
Tender For maintenance of e.i in rb at chandigarh. (addition/ alteration of e.i in house no. 83, sector-23, house no. 320 and 3947, sector-22, chandigarh). - dsr item no. 1.15rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /pvc conduit including dismantling as required., group a., group b., dsr item no. 2.18 supplying and fixing 20amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required., dsr item no. 1.16rewiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required., dsr item no. 1.17supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required., 3 x 1.5 sq. mm, 3 x 2.5 sq. mm, 3 x 4 sq. mm, dsr item no.1.21supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25mm, dsr item no.1.23supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required., 5/6 amps switch, 2 way 5/6 a switch, 3 pin 5/6 a. socket outlet, dsr item no. 1.29 supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required., dsr item no. 1.30 supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required., dsr item no. 1.33supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required., dsr item no.1.38 supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required., dsr item no.2.3 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator), 12 way, double door, dsr item no. 2.4 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb/ rccb/ isolator)., 4 way (4 + 12) double door, dsr item no. 2.10 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole, double pole, triple pole and neutral, supply and erection of electronic step type socket type fan regulator in existing b.l. sheet including making connection and petty material reqd. to complete the job. the fan regulator should be of anchor panta / havells reo/ gold medal essenza make only., supply and erection of b.l. holde
Tender For sealed item rate tenders are invited from reputed, experience & financially sound contractors who has 10 years' experience in civil & structural repairs, plumbing, waterproofing, painting & other miscellaneous work soham heights co.op.hsg.soc.ltd.
Tender For repair /replacement of perimeter light securiy light garden light solar light area light pole painting and all connected e/m item at nms under age (i) nabagram
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim