Get complete information related to latest Pvc Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pvc Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pvc Item Tenders.
Tender For supply of supply of single mode, 24 core, 9-125mm os2 unitubearmored ofc cable -as per specifications , supply of 24 port fiber lc compatible fully loaded liu along with pigtails, connectors and all other required accessories- as per specification , supply of fully loaded non poe managed l2 switch with 24 copper ports and 4 sfp plus ports with 4 sfp module and 24 port patch panel , supply of 42u server rack including cable manager and all required accessories complete-as per specifications , supply and laying of blue colour cat 6 stp data cable through pvc pipe with all required accessories -as per specifications , supply and laying of red colour cat 6 stp data cable through pvc pipe with all required accessories-as per specifications , cat6 stp rj 45 io face plate with box and jack along with standard length of patch cable , supply of 40 mm diameter blue colour plb hdpe pipe-as per specifications , supply of lc-sc 3 meter duplex fiber patch cord-as per specifications , supply of lc-lc 3 meter duplex fiber patch cord-as per specifications , supply of lc-lc 5 meter duplex fiber patch cord-as per specifications , supply of lc-lc 10 meter duplex fiber patch cord-as per specifications , supply of pvc conduit pipe 25mm diameter-as per specifications , supply of ip 68 fiber joint enclosure for 24 core ofc-as per specifications , supply of optical fiber meter with all required accessories-as per specifications , supply of nonslotted solid pvc wire raceway channel 100mm x 100mm as per specifications , laying or pulling of 24 core optical fiber cable in hdpe 40mm dia ducts using trenchless technology primarily involves horizontal directional drilling , indoor laying of ofc through pvc pipe in existing duct or cable tray with mounting acessories -as per specifications , installation, splicing testing, documentation and commissioning charges-as per specifications ) /bid number: gem/2025/b/7031505 * /dated: 22-12-2025 & & / bid document1 / 18
Tender For e.i for setting up of work station system in the audit branch of administrative office in p.u campus, sector-14, chandigarh - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls/hffr pvc insulated copper conductor single core cable etc. as required (dsr 1.8), group c (dsr 1.8.3), rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required (dsr 1.15), group c (dsr 1.15.3), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.17), 3 x 2.5 sq. mm (dsr 1.17.12), 3 x 4 sq. mm (dsr 1.17.21), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.21), 25mm (dsr 1.21.2), supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (dsr 1.22), 75 mm x 75 mm x 60 mm deep (dsr 1.22.1), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (dsr 1.24), 5/6 a switch (dsr 1.24.1), 3 pin 5/6 a socket outlet (dsr 1.24.4), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. (dsr 1.28), 3 module (dsr 1.28.2), 6 module (dsr 1.28.4), 8 module (dsr 1.28.5), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required (dsr 1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required (dsr 1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (dsr 2.4), 4 way (4 + 12), double door (dsr 2.4.1), supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr 2.10), single pole (dsr 2.10.1), supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2.16, providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (dsr 5.18), supplying, drawing, installation, testing and commissioning of cat6a utp 4 pair, 23 awg solid copper cable in existing conduit/ on surface, u/ftp, lszh, non-plenum, horizontal (solid) cable suitable for high speed data networking application supporting upto 10gbps over a 100 meter channel. the 4 unshielded twisted pairs (utp) cable with color coded insulation for easy indentification should have flame properties i.e. flammability test - iec 60332-1, smoke density - iec 61034, lszh standards compliance: ansi/tia- 568 c.2, iso/iec 11801
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2); contract for network arc of trombay unit- 1 12 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, mtr 3000, 2 24 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, no 2000, 3 lc-sc single mode 9/125 duplex fibre patch cord of minimum 2 meter length, make:, dlink/ digilink/molex/tyco/amp/systimax/r&m/panduit or equivalent, no 50, 4 utp cat 5e cable ( 300 meter box), make: dlink/ digilink/ tyco/ amp/ systimax/, r&m/panduit/rit or equivalent, no 70, 5 modular type cat 5e wall mount information outlet with one rj 45 port and box,, make: dlink/digilink/tyco/ amp/systimax/ r&m/ panduit /rit or equivalent, no 1000, 6 cat 5e rj 45 jacks (1 box of 100 nos. connectors), make: dlink/digilink /molex/tyco, /amp/ systimax/ r&m/ panduit/rit or equivalent, no 50, 7 utp cat 6 cable ( 300 meter box), make: dlink/digilink /molex/tyco /amp /systimax/, r&m/panduit/rit or equivalent, no 20, 8 1 inch pvc casing caping 1 conduit, t -joint accessories, couplers etc. for fixing, isi, make, mtr 1000, 9 6 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 10 9 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 11 outdoor water proof underground enclosure box for ofc splicing of 24 core splicing,, make: raycaum / mx or equivalent, no 100, 12 wifi extender repeater signal booster, 300mbps make: dlink or equivalent no 20, sr item description in supply uom estimated, qty, 13 underground digging 2 feet deep in soft soil, backfilling for restoration to original, state, mtr 4000, 14 underground digging 2 feet deep in hard soil, & backfilling for restoration to original, state, mtr 1000, 15 underground digging 2 feet deep in tar road & backfilling for restoration to original, state, mtr 500, 16 underground digging 2 feet deep in concrete & backfilling for restoration to original, state, mtr 500, 17 pulling of fo cables inside duct and laying in underground trench mtr 5000, 18 pulling of fo cables inside casing caping / conduits and saddling inside building mtr 3000, 19 pulling of utp cables inside duct and laying in underground trench mtr 2000, 20 pulling of utp cables inside casing caping / conduits and saddling inside building mtr 15000, 21 pulling of fo cables / utp cables inside duct and laying on existing cable tray of 15, feet hight from ground using scaffolding / articulate booms, mtr 3000, 22 termination of utp cat 5/6 cable in rj45 information outlet (i/o) / jacks, fixing of i/o, box on wall, no 2000, 23 otdr testing for fo cable core no 1000, 24 splicing of sm / mm fo cable cores in liu / enclosure box & dressing no 5000, 25 installation / mounting of 6u / 9u rack on wall no 25, 26 one no onsite manpower qtr 12.