Get complete information related to latest Radar Altimeter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radar Altimeter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radar Altimeter Tenders.
Tender For purchase of fire safety and fighting laboratory equipment for fts department - purchase of fire safety and fighting laboratory equipment for fts department, cleveland open cup (coc) apparatus standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 c per minute (as per standard) temperature range: (-6 to 400) c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valve body: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hzsafety: overheat protection heat insulation, pensky-martens closed cup apparatus standard compliance: astm d93 / is 1448 (part 21) type: pensky-martens closed cup (motorized, digital type preferred) test cup: brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system: heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustableignition:pilot flame with automatic shutter mechanismtemperature measurement:thermometer or digital sensor (ip-28c or astm)digital temperature displaypower supply:230v ac, 50 hzsafety: over-temperature cut-off flame safety control
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For mechatronic and iot laboratory equipments - measurement of linear/ angular position, speed and direction control of dc servomotor, ac servomotor and instruction motors.as per annexure., measurement of pressure , temperature and force using transducers rp2040 carrier board.as per annexure., addition, subtraction, multiplication programming in 8051 and interfacing of stepper motor, dc motor and traffic light interface.as per annexure., vision based image acquisition and processing technique for inspection and classification.as per annexure.
Tender For bid to ras corrigendum : supply of high speed uav airframe and subsystems c c - airframe manufacturing as per drawing , drone electro mechanical actuators , engine 40kg n thrust jet engine , landing gear , gps aided interial navigation system , fcc , uhf data link , uhf ground antenna , drone airborne antenna , drone alt radaraltimeter , cable harness , system and sub system flight integration , aircraft moulding tool
Tender For purchase of non consumable items for physics laboratory department of basic engineerin - purchase of physics laboratory equipment for basic engineering department, "digital balance weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led ", "joule’s calorimetercopper vessel, battery eliminator3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (02a), voltmeter (0-5v), thermometer (alcohol), stop clock ", "ic regulated battery eliminator ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a. ", "galvanometer moving coil type, 30-0-30 scale, unbranded with bhel specification-sensitivity 0.143mm/v ", "voltmeter dc voltmeter; range 0–10 v, analog ", "ammeter dc (0 - 2 amp) ", "parallelogram apparatus parallelogram law of forces apparatus fitted with stand ", "decade resistance box resistance box 12 month warranty (dial type) -manganin coil- 2 dials ", sonometer apparatus sonometer with meter scale attached along with knife edge, tuning forks set 256, 384, 512 ranges, hammer, slotted weight - 500 gm each to a total of 3 kg. brass wire (5 m) , travelling microscope branded travelling microscope 0200 mm horizontal and 0-150 mm vertical measurement, potentiometer it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements, viscosity apparatus • stoke's apparatus with metre scale attached and long cylindrical glass jar, glass beads small size (1 box), screw gauge (0-15 mm, "rheostat high-grade ceramic tube, oxidized resistance wire, 0.5a5a, range 10ω–100ω. ", deflection magnetometer apparatus • to deflection magnetometer apparatus with compass box and two short bar magnets, "solar cell kit the apparatus consist of variable dc power supply, led, solar cell and two multimeters (or an ammeter and a voltmeter). a variable dc power supply of 05v. light source is provided by led. the illumination intensity of the led can be controlled ", wheatstone bridge kit ujt series arm: four decade dials in steps of thousands, hundreds, tens, & units of ohm's. ratio arm: the ratio arm of the bridge is capable of selecting multiplying factor of 0.001, 0.01, 0.1, 1, 10, 100, 1000 for resistance measurements. two press keys are provided, one marked b is for battery & one marked g is for galvanometer one toggle switch is provided for internal battery a sensitive galvanometer is provided in the bridge, ohm's law verification kit battery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), standard resistance coil of 1, 2 ohm (2-set) wound on a wooden bobbin, "torsional pendulum torsional pendulum metallic disc, symmetrical masses and pendulum stand, steel wire ", compound bar pendulum one meter long iron strip well painted with holes at a distance of every 5 cm and also with pair of brackets and a heavy base table top stand with stop clock, "meter bridge type: 1 m length, with uniform wire (resistance wire) material: constantan or manganin (low temperature coefficient) scale: 0–100 cm, engraved or printed base: wooden or metal, rigid, non-conductive support joints / terminals: brass or copper, fixed for connections 2. galvanometer type: analog, moving coil or digital (for null detection) range: sensitive to detect microampere currents internal resistance: high, typically ~100 ω or as specified 5. cells / power supply type: leclanché cells (1.5 v each) or dc power supply number: 2–4 cells in series (or supply ~3–6 v) "
Tender For gauge for inner labyrinth measurement on shaft as per clw drawing no. 3tjf.096.040. alt-01. note:-(i) gauge should be supplied along with wooden box for carrying it. (ii) firm has to submit calibration certificate from nabl or govt. approved laboratory along with supply. make/brand- saad or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc power supply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc power supply compact designeasy to operatethe instrument should have following technical specifications:dc power supply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc power supply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase power light indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: ac power supply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop