Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit heater for c/f machin
Tender For corrigendum : maintenance of various scheme under na ii/ez.sh-repair and maintenance of rain water harvesting system and installation of piezometer with digital water level recorder (dwlr) at dda office complex, shakarpur.
Tender For supply of instrument spare and annual maintenance contract - circular charts:- i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :- i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :- i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:- i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:- i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:- i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:- a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperature controller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :- (i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :- i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :- (i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amc super-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperature control system of transit
Tender For supply, installation, commissioning, testing, training and maintenance of instrumentation of taraka dam in mysore district of karnataka state under drip-ii (package-3) - world bank aided. - automatic water level recorder, weather station, uplift pressure measurement system, jelly filled cable, cable termination and switch box, spvc cable, laying of armoured jelly filled cable, providing and installing of digital readout unit, providing and installing of data collection unit and transmission system server, settlement plate/survey markers, data collection unit and transmission equipment, providing and installing of electronic sirens, providing installation and commissioning of tilt meters, vibrating wire piezometer/pore pressure meter, drilling of 1 mts bore holes, pair armored jelly filled cable of standard, cable termination and switch box-2, laying of armoured jelly filled cable-2, pvc pipe, v noutch, slope stability analysis, masw test to estimate dynamic soil constant, installation charges, installation charges for drainage gallery instrumentation, total station, amc
Tender For supply of digital water level recorder with telemetry , installation, testing and commissioning , camc chagges for 01st year after warranty , camc chagges for 02nd year after warranty
Tender For supply of various log books e e - two hundred book size a four , sraw log book no of pages two hundred book size a four , dravan log book no of pages two hundred book size a four , boat log book no of pages two hundred book size a four , dravan pol log book no of pages two hundred book size a four , maintenance and defect register no of pages two hundred book size a four , llrw log book no of pages two hundred book size a four , proceeding ashore book no of pages two hundred book size a four , senior sailor proceeding ashore book no of pages two hundred book size a four , junior sailor proceeding ashore book no of pages two hundred book size a four , important key book no of pages two hundred book size a four , night round book no of pages two hundred book size a four , general key book no of pages two hundred book size a four , gangway in out book no of pages two hundred book size a four , punishment book no of pages two hundred book size a four , visitor book no of pages two hundred book size a four , petrol register no of pages two hundred book size a three , diesel register no of pages two hundred book size a three , kilo meter card log book no of pages two hundred book size a three , car diary esv mk ii no of pages two hundred book size a three , car diary maruti gypsy no of pages two hundred book size a three , car diary royal enfield no of pages two hundred book size a three , car diary ambulance no of pages two hundred book size a three , car diary swift dzire no of pages two hundred book size a three , reader daily parameters log book no of pages three hundred book size a three , annealing oven log book no of pages three hundred book size a four , internal calibration of annealing oven log book no of pages three hundred book size a four , dcf evaluation log book no of pages three hundred book size a four , rcf evaluation log book no of pages three hundred book size a four , verification of annealing log book no of pages three hundred book size a four , irradiationsystem log book no of pages three hundred book size a four , daily radiation monitoring report no of pages two hundred fifty book size a four , weekly quarterly radiation monitoring report no of pages two hundred book size a four , third eye data log book no of pages two hundred book size a four , functional checks of portable anf fixed rmes log book no of pages two hundred book size a four , aerosol samples log book no of pages one fifty hundred book size a four , calibration of radiationcountingsystem log book no of pages one fifty hundred book size a four , functional checks of laboratory equipment non radiac log book no of pages two hundred book size a four , functional checks of rmes and non rmes esv mk ii log book no of pages two hundred book size a four , pll log book no of pages two hundred book size a four , ars log book no of pages two hundred book size a four , eric log book no of pages two hundred book size a four
Tender For supply of various log books d d - two hundred book size a four , sraw log book no of pages two hundred book size a four , dravan log book no of pages two hundred book size a four , boat log book no of pages two hundred book size a four , dravan pol log book no of pages two hundred book size a four , maintenance and defect register no of pages two hundred book size a four , llrw log book no of pages two hundred book size a four , proceeding ashore book no of pages two hundred book size a four , senior sailor proceeding ashore book no of pages two hundred book size a four , junior sailor proceeding ashore book no of pages two hundred book size a four , important key book no of pages two hundred book size a four , night round book no of pages two hundred book size a four , general key book no of pages two hundred book size a four , gangway in out book no of pages two hundred book size a four , punishment book no of pages two hundred book size a four , visitor book no of pages two hundred book size a four , petrol register no of pages two hundred book size a three , diesel register no of pages two hundred book size a three , kilo meter card log book no of pages two hundred book size a three , car diary esv mk ii no of pages two hundred book size a three , car diary maruti gypsy no of pages two hundred book size a three , car diary royal enfield no of pages two hundred book size a three , car diary ambulance no of pages two hundred book size a three , car diary swift dzire no of pages two hundred book size a three , reader daily parameters log book no of pages three hundred book size a three , annealing oven log book no of pages three hundred book size a four , internal calibration of annealing oven log book no of pages three hundred book size a four , dcf evaluation log book no of pages three hundred book size a four , rcf evaluation log book no of pages three hundred book size a four , verification of annealing log book no of pages three hundred book size a four , irradiationsystem log book no of pages three hundred book size a four , daily radiation monitoring report no of pages two hundred fifty book size a four , weekly quarterly radiation monitoring report no of pages two hundred book size a four , third eye data log book no of pages two hundred book size a four , functional checks of portable anf fixed rmes log book no of pages two hundred book size a four , aerosol samples log book no of pages one fifty hundred book size a four , calibration of radiationcountingsystem log book no of pages one fifty hundred book size a four , functional checks of laboratory equipment non radiac log book no of pages two hundred book size a four , functional checks of rmes and non rmes esv mk ii log book no of pages two hundred book size a four , pll log book no of pages two hundred book size a four , ars log book no of pages two hundred book size a four , eric log book no of pages two hundred book size a four