Get complete information related to latest Radiography Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiography Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiography Tenders.
Tender For corrigendum : providing of custom bid for services - biennial rate contract for radiography & other ndt services at brbcl nabinagar (4 x 250 mw units)
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - thickness testing opf molasses tank and radiography of welding joints of ss molasses tank; as per tender documents; as per tender documents
Tender For supply of non interleaved (nif) ultra fine grain industrial x-ray radiography film (30 cm x 40 cm) with ve , non interleaved (nif) ultra fine grain industrial x-ray radiography film (30 cm x 40 cm) with hi
Tender For bogie frame to drg. no. (a) icf/mrvc/d-0-3-001, alt "n", col-ii (or) (b) icf/mrvc/d/bt-0-3-001, alt "c", col -ii along with damper fixing bracket to drg. no. (339)ac/dcemu/d6-0-1-602,col.i - 4 nos andbolt complete to drg. no. emu/m/3ph-0-2-002, alt "c", col.i - 16 sets bogie frame to be supplied without nylon bushes where ever applicable and shall confirm to rdso/specn.c-9202, rev-2 or latest. the firm shall fulfil the requiremnt as per icf/md/specn/147, issue status 01, rev-02 with amendment no- 02. special condition : - suppliers commitment will be there to supply as per drawing -(a) ( for dash pot arrangement ) or as per new drawing - (b) ( for adoption of conical spring ). - one month notice willbe given to vendor whether he has to supply as per drawing - (a) or drawing - (b). -rate quoted will be applicable to both drawing - (a) and drawing - (b) . i) paint scheme shall be as per drawing. ii) qap to format icf/ims/md/f-31 shall be prepared along with relevant documents and kept ready for developmental/educational order. iii)firm should supply bogie frame along with the dimensional report, stress relieving report and radiography films. iv) firm should have induction/electric furnace for stress relieving of bogie frame. v) prototype inspection is applicable only for first time of developmental/educational order. vi) stage inspection to be done as below. (a) raw material stage 1. ensure the raw material used using portable spectrometer machining stage 1. dimensional checks 2. edge preparations (b)welding stage 1. weld parameter to be checked and recorded. (c) surface preparation and painting stage. 1. short/sand blast to the requirements. 2. painting process as per the specification. 3. final product inspection. [ warrantyperiod: 30 months after the date of delivery ]
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8